Comparison of digital PCR systems for the analysis of liquid biopsy samples of patients affected by lung and colorectal cancer
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND AIMS: Highly sensitive technologies are available for the molecular characterization of solid tumors, including digital PCR (dPCR). Liquid biopsy, based on the analysis of cell-free DNA (cfDNA), is often used to assess EGFR or RAS alterations in lung and colorectal cancers. Our study aimed to compare the results of two different dPCR platforms for the detection of mutations in cfDNA. METHODS: Plasma samples from lung and colorectal cancer patients collected as per routine procedures have been tested. cfDNA Was extracted from plasma, and samples were screened on the droplet digital PCR (ddPCR, BioRad) and solid dPCR QIAcuity (Qiagen). RESULTS: A total of 42 samples were analyzed, obtained from 20 Non-Small Cell Lung Cancer (NSCLC) patients carrying an EGFR or a KRAS mutation on tissue at diagnosis, and from 22 samples of colorectal cancer (CRC) patients, 10 of which presenting a KRAS mutation. EGFR mutation detection was 58.8% for ddPCR and 100% for dPCR (κ = 0.54; 95% CI, 0.37-0.71), compared to tissue results. The detection rate for RAS mutations was 72.7% for ddPCR and 86.4% for dPCR (κ = 0.34; 95% CI, 0.01-0.68), compared to tissue results. CONCLUSIONS: This study showed moderate agreement between dPCR and ddPCR. Sampling effect or threshold settings may potentially explain the differences in the cfDNA data between the two different platforms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, comparisons of different digital PCR platforms in their ability to accurately or precisely estimate gene copy numbers are scarce24–28.”
From Comparing the precision of two digital PCR applications for copy number comparisons in protists (2025) · cites this paper as [25]
In the citing paper
“Other studies that compared reproducibility and general platform performance have used DNA originating from plasmids, tumor cells, bacteria or viruses25,26,28,45,73.”
From Comparing the precision of two digital PCR applications for copy number comparisons in protists (2025) · cites this paper as [25]
In the citing paper
“These studies showed a general agreement between both platforms and suggest that the observed differences might be caused by threshold settings.”
From Comparing the precision of two digital PCR applications for copy number comparisons in protists (2025) · cites this paper as [25]
In the citing paper
“Comparisons between the QX200 ddPCR and the QIAcuity ndPCR platforms were so far mainly conducted for medical investigations of viruses or mutation analyses25,45.”
From Comparing the precision of two digital PCR applications for copy number comparisons in protists (2025) · cites this paper as [25]
In the citing paper
“These studies showed a general agreement between both platforms and suggest that the observed differences might be caused by threshold settings.”
From Comparing the precision of two digital PCR applications for copy number comparisons in protists (2025) · cites this paper as [25]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-throughput droplet digital PCR system for absolute quantitation of DNA copy number
Hindson, B. J., Ness, K. D., Masquelier, D. A., Belgrader, P., Heredia, N. J., Makarewicz, A. J., Bright, I. J., Lucero, M. Y., Hiddessen, A. L., Legler, T. C., et al. (2011) · Analytical Chemistry · doi:10.1021/ac202028g · Cited by 2,792
Liquid biopsy enters the clinic — implementation issues and future challenges
Ignatiadis, M., Sledge, G. W., & Jeffrey, S. S. (2021) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-020-00457-x · Cited by 1,191
Research works printed but not linked: 15
- Mader, 2017, Liquid biopsy: current status and future perspectives, Oncol. Res. Treat., 40, 404, 10.1159/000478018 · DOI · Paper page
- Russo, 2021, The molecular profiling of solid tumors by liquid biopsy: a position paper of the AIOM-SIAPEC-IAP-SIBioC-SIC-SIF Italian Scientific Societies, ESMO Open, 6, 10.1016/j.esmoop.2021.100164 · DOI
- Fernandez-Lazaro, 2020, Liquid Biopsy as Novel Tool in Precision Medicine: Origins, Properties, Identification and Clinical Perspective of Cancer's Biomarkers, Diagnostics (Basel), 10
- Del Re, 2019, The increase in activating EGFR mutation in plasma is an early biomarker to monitor response to osimertinib: a case report, BMC Cancer, 19, 410, 10.1186/s12885-019-5604-6 · DOI
- Malone, 2020, Molecular profiling for precision cancer therapies, Genome Med., 12, 8, 10.1186/s13073-019-0703-1 · DOI · Paper page
- Moreno-Manuel, 2021, dPCR application in liquid biopsies: divide and conquer, Expert. Rev. Mol. Diagn., 21, 3, 10.1080/14737159.2021.1860759 · DOI
- Garcia, 2018, Cross-platform comparison for the detection of RAS mutations in cfDNA (ddPCR Biorad detection assay, BEAMing assay, and NGS strategy), Oncotarget, 9, 21122, 10.18632/oncotarget.24950 · DOI
- O'Leary, 2019, Comparison of BEAMing and Droplet Digital PCR for Circulating Tumor DNA Analysis, Clin. Chem., 65, 1405, 10.1373/clinchem.2019.305805 · DOI
- Thress, 2015, EGFR mutation detection in ctDNA from NSCLC patient plasma: A cross-platform comparison of leading technologies to support the clinical development of AZD9291, Lung Cancer, 90, 509, 10.1016/j.lungcan.2015.10.004 · DOI · Paper page
- Bettegowda, 2014, Detection of circulating tumor DNA in early- and late-stage human malignancies, Sci. Transl. Med., 6, p. 224ra24, 10.1126/scitranslmed.3007094 · DOI · Paper page
- Bartels, 2017, Molecular Analysis of Circulating Cell-Free DNA from Lung Cancer Patients in Routine Laboratory Practice: A Cross-Platform Comparison of Three Different Molecular Methods for Mutation Detection, J. Mol. Diagn., 19, 722, 10.1016/j.jmoldx.2017.05.008 · DOI
- Beije, 2016, Somatic mutation detection using various targeted detection assays in paired samples of circulating tumor DNA, primary tumor and metastases from patients undergoing resection of colorectal liver metastases, Mol. Oncol., 10, 1575, 10.1016/j.molonc.2016.10.001 · DOI
- Iwama, 2017, Monitoring of somatic mutations in circulating cell-free DNA by digital PCR and next-generation sequencing during afatinib treatment in patients with lung adenocarcinoma positive for EGFR activating mutations, Ann. Oncol., 28, 136, 10.1093/annonc/mdw531 · DOI
- Ye, 2021, The diagnostic accuracy of digital PCR, ARMS and NGS for detecting KRAS mutation in cell-free DNA of patients with colorectal cancer: A systematic review and meta-analysis, PLoS One, 16, e0248775, 10.1371/journal.pone.0248775 · DOI
- Fernandez-Lazaro, 2020, Clinical Perspective and Translational Oncology of Liquid Biopsy, Diagnostics (Basel), 10
Cited by
Digital PCR: From early developments to its future application in clinics
Trouchet, A., Gines, G., Benhaim, L., & Taly, V. (2025) · Lab on a Chip · doi:10.1039/d5lc00055f · Cited by 43
Comparing the precision of two digital PCR applications for copy number comparisons in protists
Gross, M., Stoeck, T., Mauvisseau, Q., Schrøder-Nielsen, A., & Dunthorn, M. (2025) · Scientific Reports · doi:10.1038/s41598-025-13143-8 · Cited by 6
Metadata
- Authors
- Crucitta, S., Ruglioni, M., Novi, C., Manganiello, M., Arici, R., Petrini, I., Pardini, E., Cucchiara, F., Marmorino, F., Cremolini, C., Fogli, S., Danesi, R., & Del Re, M.
- Venue
- Clinica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2023-02
- Volume
- 541
- Pages
- 117239
- ISSN
- 0009-8981
- Cited by
- 40
- References
- 2
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by/4.0/ (vor, 223 d)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.