The DOI matches its Crossref record; 87 of the 87 references it cites were found in a registry or an index; none of the 44 sources its claims cite is checked for support yet.
Comparing the precision of two digital PCR applications for copy number comparisons in protists
Open accessAbstract
Microorganisms play key roles in ecosystem functioning, making reliable methods for assessing their dynamics essential. Advances in molecular technologies now enable their quantification in environmental samples based on DNA marker genes. Among these, digital PCR has emerged as a powerful tool for detecting and quantifying organisms based on their gene copies, with numerous platforms that are currently available. However, these platforms differ in their underlying technologies, and comparative studies that evaluate the performance and reproducibility remain limited. Here we compared different platform parameters across the QX200 digital droplet PCR from Bio-Rad and the QIAcuity One nanoplate-based digital PCR from QIAGEN. We used synthetic oligonucleotides and DNA extracted from varying cell numbers of the ciliate Paramecium tetraurelia and additionally tested the impact of two restriction enzymes on gene copy number quantification. Both platforms demonstrated similar detection and quantification limits and yielded high precision across most analyses. We found a general tendency of higher precision using the HaeIII restriction enzyme instead of EcoRI, especially for the QX200 system. Gene copy number estimates from ciliate DNA were reproducible between platforms and showed a linear trend for an increasing number of cells for both platforms. These findings highlight the importance of cross-platform evaluations to ensure robust and reproducible gene copy number analysis in unicellular eukaryotes and support a potential broader application of digital PCR in environmental monitoring studies.
Overview
CoChat Summary
TL;DR
This study compared the QX200 droplet digital PCR and QIAcuity One nanoplate digital PCR for gene copy number quantification using synthetic oligonucleotides and DNA from the ciliate *Paramecium tetraurelia*. Both platforms showed similar dynamic range and high precision, with HaeIII generally improving precision and reproducible but systematically different copy number estimates between platforms.
Key findings
- LOD was ca. 0.39 copies/µL input for ndPCR (15.60 copies/reaction for 40 µL) and ca. 0.17 copies/µL for ddPCR (3.31 copies/reaction for 20 µL); LOQ was 1.35 copies/µL (54 copies/reaction) for ndPCR and 4.26 copies/µL (85.2 copies/reaction) for ddPCR. Above LOQ, CVs ranged from 7–11% for ndPCR and 6–13% for ddPCR.
- Synthetic oligonucleotide accuracy showed good model fit (ndPCR R²adj = 0.98; ddPCR R²adj = 0.99), but measured gene copy numbers were consistently lower than expected for both platforms, with discrepancies exceeding 50% of expected concentration for some dilution levels.
- HaeIII generally gave higher precision than EcoRI, especially for ddPCR: ddPCR CVs were 2.5–62.1% with EcoRI and all below 5% with HaeIII; ndPCR CVs were 0.6–27.7% with EcoRI and 1.6–14.6% with HaeIII.
- For *P. tetraurelia* DNA from 5–100 cells, ndPCR gave significantly higher mean estimated gene copy numbers than ddPCR for both EcoRI (Wilcoxon W = 1015, p < 0.001) and HaeIII (W = 943, p < 0.001); average copy number increased with cell number (R² = 0.92–0.95), except 5 cells averaged higher than 10 cells. Reproducibility between platforms was R² = 0.96 for synthetic oligonucleotides, R² = 0.97 for HaeIII and R² = 0.95 for EcoRI with ciliate DNA; CCC was 0.96 (95% CI 0.94–0.98) for HaeIII and 0.92 (95% CI 0.88–0.95) for EcoRI.
Methods
- Cross-platform comparison of QIAcuity One nanoplate dPCR (24-well nanoplates with 26,000 partitions, 40 µL reactions) and QX200 droplet dPCR (up to 20,000 droplets, 20 µL reactions), both using EvaGreen and PAC-F/R primers amplifying a 237 bp LSU rRNA fragment.
- Samples were synthetic oligonucleotides and DNA extracted from *P. tetraurelia* stock 51 cells (5–100 cells; some samples from a previous study, with additional 10–20 cell extractions); dilution series had 11 levels at 1:10 with 10 replicates, and ciliate DNA samples were run in triplicate, with EcoRI or HaeIII restriction enzymes.
- Analyses in R v4.3.1 included LOD/LOQ estimation (95% detection; CV ≤ 35% for LOQ), linear regression with AIC model selection, paired t-tests or Wilcoxon signed-rank tests, Concordance Correlation Coefficient, Bland-Altman analysis (weighted when needed), and coefficient of variation.
Limitations
- The paper states that LOD and LOQ estimates refer to optimal samples without non-target DNA or co-extracted substances, and it is unsure how they would be affected by environmental samples, extraction efficiencies, or inhibition such as humic acids; it also notes that a 1:10 dilution series limited resolution compared with a 1:5 series.
- The paper states that accuracy discrepancies were inconclusive and could stem from inaccurate DNA starting concentrations, degraded or damaged synthetic oligonucleotides, or partition misclassification (type II error), though misclassification was considered minor.
- Evident from the text: the study used only one ciliate species (*P. tetraurelia*), two platforms, two restriction enzymes, and no environmental samples; low cell concentrations (5 vs. 10 cells) were not reliably differentiated, biological replicate CVs reached 44%, and platform-specific features such as maximum template input volume and cost were not addressed.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 86 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Precision estimates using DNA originating from P. tetraurelia showed differences depending on the choice of restriction enzyme (Fig. 3).”
§ Comparing the precision of two digital PCR applications for copy number comparisons in protists > Results > Accuracy and precision
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Both platforms demonstrated similar detection and quantification limits and yielded high precision across most analyses.”
§ Comparing the precision of two digital PCR applications for copy number comparisons in protists > Abstract
boosted- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“For ndPCR the LOQ was determined at 1.35 copies/µL input (54 copies/reaction)”
§ Comparing the precision of two digital PCR applications for copy number comparisons in protists > Results > Limit of detection (LOD) and limit of quantification (LOQ)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The LOD of ndPCR was ca. 0.39 copies/µL input (15.60 copies/reaction for a 40µL reaction; see Data S1.1 in Supplementary Material)”
§ Comparing the precision of two digital PCR applications for copy number comparisons in protists > Results > Limit of detection (LOD) and limit of quantification (LOQ)
hedgedn = 6- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Both platforms demonstrated similar detection and quantification limits and yielded high precision across most analyses.”
§ Comparing the precision of two digital PCR applications for copy number comparisons in protists > Abstract
boosted- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
42 more claims
Create a free account to see all 102 claims and to verify the 44 references still open.
- It may state two separate claims as one. 41
- Probably not a substantial claim. 18
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Comparing the precision of two digital PCR applications for copy number comparisons in protists > Results > Limit of detection (LOD) and limit of quantification (LOQ)
“For the other dilution levels, DNA measurements were not possible due to the limits of the fluorometer and were therefore not compared.”
§ Comparing the precision of two digital PCR applications for copy number comparisons in protists > Materials and methods > Data analysis
“Since the linear range only covers concentrations between 0.2 and 400 ng only the first two dilution levels could reliably be quantified.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Comparing the precision of two digital PCR applications for copy number comparisons in protists > Discussion
“We compared the 4-cutter restriction enzyme HaeIII with the 5-cutter restriction enzyme EcoRI.”
§ Comparing the precision of two digital PCR applications for copy number comparisons in protists > Materials and methods > Molecular analysis
“We selected two restriction enzymes from New England Biolabs (NEB, Frankfurt am Main, Germany), one 6-cutter restriction enzyme (EcoRI) and one 4-cutter restriction enzyme (HaeIII), that were suggested for the QIAcuity EvaGreen dPCR assay.”
Citations
Cites
Wickham, H., Averick, M., Bryan, J., Chang, W., McGowan, L., François, R., Grolemund, G., Hayes, A., Henry, L., Hester, J., et al. (2019) · Journal of Open Source Software · doi:10.21105/joss.01686 · Cited by 22,138
Ror2 signaling regulates Golgi structure and transport through IFT20 for tumor invasiveness
Nishita, M., Park, S.-Y., Nishio, T., Kamizaki, K., Wang, Z., Tamada, K., Takumi, T., Hashimoto, R., Otani, H., Pazour, G. J., et al. (2017) · Scientific Reports · doi:10.1038/s41598-016-0028-x · Cited by 15,947
Santos, A. G., da Rocha, G. O., & de Andrade, J. B. (2019) · Scientific Reports · doi:10.1038/s41598-018-37186-2 · Cited by 8,495
The Influence of Functional Diversity and Composition on Ecosystem Processes
Tilman, D., Knops, J., Wedin, D., Reich, P., Ritchie, M., & Siemann, E. (1997) · Science · doi:10.1126/science.277.5330.1300 · Cited by 3,199
High-throughput droplet digital PCR system for absolute quantitation of DNA copy number
Hindson, B. J., Ness, K. D., Masquelier, D. A., Belgrader, P., Heredia, N. J., Makarewicz, A. J., Bright, I. J., Lucero, M. Y., Hiddessen, A. L., Legler, T. C., et al. (2011) · Analytical Chemistry · doi:10.1021/ac202028g · Cited by 2,792
Vogelstein, B., & Kinzler, K. W. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9236 · Cited by 1,770
Absolute quantification by droplet digital PCR versus analog real-time PCR
Hindson, C. M., Chevillet, J. R., Briggs, H. A., Gallichotte, E. N., Ruf, I. K., Hindson, B. J., Vessella, R. L., & Tewari, M. (2013) · Nature Methods · doi:10.1038/nmeth.2633 · Cited by 1,488
Evaluation of a Droplet Digital Polymerase Chain Reaction Format for DNA Copy Number Quantification
Pinheiro, L. B., Coleman, V. A., Hindson, C. M., Herrmann, J., Hindson, B. J., Bhat, S., & Emslie, K. R. (2012) · Analytical Chemistry · doi:10.1021/ac202578x · Cited by 1,055
ggplot2: Create Elegant Data Visualisations Using the Grammar of Graphics
Wickham, H., Chang, W., Henry, L., Pedersen, T. L., Takahashi, K., Wilke, C., Woo, K., Yutani, H., Dunnington, D., & van den Brand, T. (2007) · CRAN: Contributed Packages · doi:10.32614/cran.package.ggplot2 · Cited by 862
Quantitation of targets for PCR by use of limiting dilution.
Sykes, P. J., Neoh, S. H., Brisco, M. J., Hughes, E., Condon, J. C., & Morley, A. A. (1992) · PubMed · Cited by 753
Research works printed but not linked: 3
- Brys, R. et al. Reliable eDNA detection and quantification of the European weather loach (Misgurnus fossilis). J. Fish Biol. 98, 399–414 (2020). · DOI
- Wickham, H., Pedersen, T. L. & Seidel, D. Scales: Scale functions for visualization, version 1.3. 0 [R package]. Preprint at (2023).
- Fox, J. et al. Package ‘car’. Vienna: R Foundation Stat. Comput. 16, 333 (2012).
Cited by
Clerkin, T. J., Smith, S., Zhu, K., Blackwood, A. D., Gallard-Gongora, J. F., Capone, D., Brown, J. D., & Noble, R. T. (2026) · Applied and Environmental Microbiology · doi:10.1128/aem.00083-26 · Cited by 3
Gross, M. R., Koll, U., Sonntag, B., & Stoeck, T. (2026) · Molecular Ecology Resources · doi:10.1111/1755-0998.70177 · Cited by 1
Self-citationMestanza, M., Trujillo, P. A. R., Hernández-Amasifuen, Á. D., Eriksson, D., Rio, A. H. D., Condori‐Apfata, J. A., & Guerrero‐Abad, J. C. (2026) · Plants · doi:10.3390/plants15071033
GC-rich regions affect amplification efficiency of neighboring amplicons in qPCR and digital PCR
Wang, X., Kruchkow, J., Rodríguez-Vargas, A., Wenzel, S., & Richer, S. M. (2026) · Scientific Reports · doi:10.1038/s41598-026-55452-6
Dalaya, A., Orbach, M. J., & Mehl, H. L. (2026) · Plant Health Progress · doi:10.1094/php-04-26-0087-rs
Metadata
- Authors
- Gross, M., Stoeck, T., Mauvisseau, Q., Schrøder-Nielsen, A., & Dunthorn, M.
- Affiliations
- Rheinland-Pfälzische Technische Universität Kaiserslautern-Landau (DE)
- University of Oslo (NO)
- Corresponding author
- Gross, Megan
- Venue
- Scientific Reports
- Published
- 2025-07-25
- Volume
- 15
- Issue
- 1
- Pages
- 27095-27095
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC12297429
- OpenAlex
- W4412707545
- Cited by
- 6
- References
- 87
- Citations by year
- 2026: 6
- FWCI
- 1.20
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Rheinland-Pfälzische Technische Universität Kaiserslautern-Landau
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › bioluminescence and chemiluminescence research
- Physical Sciences › Environmental Science › Ecology › Environmental DNA in Biodiversity Studies
- Keywords
- digital PCR, gene copy number quantification, protists, ciliates, Paramecium tetraurelia, cross-platform comparison, restriction enzymes, HaeIII, EcoRI, environmental monitoring, precision and reproducibility
- MeSH terms
- Reproducibility of Results, DNA, Protozoan, Polymerase Chain Reaction, Gene Dosage, DNA Copy Number Variations
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-18, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-18 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparing the precision of two digital PCR applications for copy number comparisons in protists. https://app.cochat.ai/papers/10.1038/s41598-025-13143-8
- The paper
- Gross, M., Stoeck, T., Mauvisseau, Q., Schrøder-Nielsen, A., & Dunthorn, M. (2025). Comparing the precision of two digital PCR applications for copy number comparisons in protists. Scientific Reports. https://doi.org/10.1038/s41598-025-13143-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.