Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 87 of the 87 references it cites were found in a registry or an index; none of the 44 sources its claims cite is checked for support yet.

Comparing the precision of two digital PCR applications for copy number comparisons in protists

Open access
Gross, Megan, Stoeck, Thorsten, Mauvisseau, Quentin, Schrøder-Nielsen, Audun, Dunthorn, Micah · 2025 · Scientific Reports

Abstract

Microorganisms play key roles in ecosystem functioning, making reliable methods for assessing their dynamics essential. Advances in molecular technologies now enable their quantification in environmental samples based on DNA marker genes. Among these, digital PCR has emerged as a powerful tool for detecting and quantifying organisms based on their gene copies, with numerous platforms that are currently available. However, these platforms differ in their underlying technologies, and comparative studies that evaluate the performance and reproducibility remain limited. Here we compared different platform parameters across the QX200 digital droplet PCR from Bio-Rad and the QIAcuity One nanoplate-based digital PCR from QIAGEN. We used synthetic oligonucleotides and DNA extracted from varying cell numbers of the ciliate Paramecium tetraurelia and additionally tested the impact of two restriction enzymes on gene copy number quantification. Both platforms demonstrated similar detection and quantification limits and yielded high precision across most analyses. We found a general tendency of higher precision using the HaeIII restriction enzyme instead of EcoRI, especially for the QX200 system. Gene copy number estimates from ciliate DNA were reproducible between platforms and showed a linear trend for an increasing number of cells for both platforms. These findings highlight the importance of cross-platform evaluations to ensure robust and reproducible gene copy number analysis in unicellular eukaryotes and support a potential broader application of digital PCR in environmental monitoring studies.

Overview

CoChat Summary

TL;DR

This study compared the QX200 droplet digital PCR and QIAcuity One nanoplate digital PCR for gene copy number quantification using synthetic oligonucleotides and DNA from the ciliate *Paramecium tetraurelia*. Both platforms showed similar dynamic range and high precision, with HaeIII generally improving precision and reproducible but systematically different copy number estimates between platforms.

Key findings

  • LOD was ca. 0.39 copies/µL input for ndPCR (15.60 copies/reaction for 40 µL) and ca. 0.17 copies/µL for ddPCR (3.31 copies/reaction for 20 µL); LOQ was 1.35 copies/µL (54 copies/reaction) for ndPCR and 4.26 copies/µL (85.2 copies/reaction) for ddPCR. Above LOQ, CVs ranged from 7–11% for ndPCR and 6–13% for ddPCR.
  • Synthetic oligonucleotide accuracy showed good model fit (ndPCR R²adj = 0.98; ddPCR R²adj = 0.99), but measured gene copy numbers were consistently lower than expected for both platforms, with discrepancies exceeding 50% of expected concentration for some dilution levels.
  • HaeIII generally gave higher precision than EcoRI, especially for ddPCR: ddPCR CVs were 2.5–62.1% with EcoRI and all below 5% with HaeIII; ndPCR CVs were 0.6–27.7% with EcoRI and 1.6–14.6% with HaeIII.
  • For *P. tetraurelia* DNA from 5–100 cells, ndPCR gave significantly higher mean estimated gene copy numbers than ddPCR for both EcoRI (Wilcoxon W = 1015, p < 0.001) and HaeIII (W = 943, p < 0.001); average copy number increased with cell number (R² = 0.92–0.95), except 5 cells averaged higher than 10 cells. Reproducibility between platforms was R² = 0.96 for synthetic oligonucleotides, R² = 0.97 for HaeIII and R² = 0.95 for EcoRI with ciliate DNA; CCC was 0.96 (95% CI 0.94–0.98) for HaeIII and 0.92 (95% CI 0.88–0.95) for EcoRI.

Methods

  • Cross-platform comparison of QIAcuity One nanoplate dPCR (24-well nanoplates with 26,000 partitions, 40 µL reactions) and QX200 droplet dPCR (up to 20,000 droplets, 20 µL reactions), both using EvaGreen and PAC-F/R primers amplifying a 237 bp LSU rRNA fragment.
  • Samples were synthetic oligonucleotides and DNA extracted from *P. tetraurelia* stock 51 cells (5–100 cells; some samples from a previous study, with additional 10–20 cell extractions); dilution series had 11 levels at 1:10 with 10 replicates, and ciliate DNA samples were run in triplicate, with EcoRI or HaeIII restriction enzymes.
  • Analyses in R v4.3.1 included LOD/LOQ estimation (95% detection; CV ≤ 35% for LOQ), linear regression with AIC model selection, paired t-tests or Wilcoxon signed-rank tests, Concordance Correlation Coefficient, Bland-Altman analysis (weighted when needed), and coefficient of variation.

Limitations

  • The paper states that LOD and LOQ estimates refer to optimal samples without non-target DNA or co-extracted substances, and it is unsure how they would be affected by environmental samples, extraction efficiencies, or inhibition such as humic acids; it also notes that a 1:10 dilution series limited resolution compared with a 1:5 series.
  • The paper states that accuracy discrepancies were inconclusive and could stem from inaccurate DNA starting concentrations, degraded or damaged synthetic oligonucleotides, or partition misclassification (type II error), though misclassification was considered minor.
  • Evident from the text: the study used only one ciliate species (*P. tetraurelia*), two platforms, two restriction enzymes, and no environmental samples; low cell concentrations (5 vs. 10 cells) were not reliably differentiated, biological replicate CVs reached 44%, and platform-specific features such as maximum template input volume and cost were not addressed.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1038/s41598-025-13143-8

Cites

87 of 87 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Fig. 1 Limit of quantification (LOQ) for dPCR (blue) and ddPCR (red). The dashed black horizontal line represents the 0.35 coefficient of variation (CV) that was used to calculate the LOQ. Dashed blue vertical line represents the LOQ for dPCR (1.35) and dashed red vertical line represents LOQ of ddPCR (4.26).
Fig. 1 Limit of quantification (LOQ) for dPCR (blue) and ddPCR (red). The dashed black horizontal line represents the 0.35 coefficient of variation (CV) that was used to calculate the LOQ. Dashed blue vertical line represents the LOQ for dPCR (1.35) and dashed red vertical line represents LOQ of ddPCR (4.26).CC BY · PubMed Central
Fig. 2 Relationship between log-transformed expected gene copy number per µl DNA calculated from Eq. 1 and log-transformed measured gene copy number per µL DNA resulting from digital PCR experiments. Red data points and regression line indicates ddPCR results and blue indicates dPCR results. For both dataset a 3rd degree polynomial model was fitted.
Fig. 2 Relationship between log-transformed expected gene copy number per µl DNA calculated from Eq. 1 and log-transformed measured gene copy number per µL DNA resulting from digital PCR experiments. Red data points and regression line indicates ddPCR results and blue indicates dPCR results. For both dataset a 3rd degree polynomial model was fitted.CC BY · PubMed Central
Fig. 3 Boxplots showing coefficient of variation of technical replicates for dPCR (blue) and ddPCR (red) for different cell numbers of P. tetraurelia using (A) EcoRI or (B) HaeIII as a restriction enzyme in the assays.
Fig. 3 Boxplots showing coefficient of variation of technical replicates for dPCR (blue) and ddPCR (red) for different cell numbers of P. tetraurelia using (A) EcoRI or (B) HaeIII as a restriction enzyme in the assays.CC BY · PubMed Central
Fig. 4 (A) Linear regression between dPCR and ddPCR for log-transformed copy number comparison of a 10-fold dilution series. (B) Linear regression between dPCR and ddPCR for copy number comparison of different cell numbers of P. tetraurelia separated by restriction enzyme.
Fig. 4 (A) Linear regression between dPCR and ddPCR for log-transformed copy number comparison of a 10-fold dilution series. (B) Linear regression between dPCR and ddPCR for copy number comparison of different cell numbers of P. tetraurelia separated by restriction enzyme.CC BY · PubMed Central

Verification

Claims the paper makes

0 Valid · 0 Not valid · 16 Not checked · 86 Own results and interpretations

42 more claims

Create a free account to see all 102 claims and to verify the 44 references still open.

See all claims — free account
  • It may state two separate claims as one. 41
  • Probably not a substantial claim. 18

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

2 of 2

Citations

Cites

Show all 87 references

Research works printed but not linked: 3

  1. Brys, R. et al. Reliable eDNA detection and quantification of the European weather loach (Misgurnus fossilis). J. Fish Biol. 98, 399–414 (2020). · DOI
  2. Wickham, H., Pedersen, T. L. & Seidel, D. Scales: Scale functions for visualization, version 1.3. 0 [R package]. Preprint at (2023).
  3. Fox, J. et al. Package ‘car’. Vienna: R Foundation Stat. Comput. 16, 333 (2012).

Cited by

See all 6

Metadata

Authors
Gross, M., Stoeck, T., Mauvisseau, Q., Schrøder-Nielsen, A., & Dunthorn, M.
Affiliations
  • Rheinland-Pfälzische Technische Universität Kaiserslautern-Landau (DE)
  • University of Oslo (NO)
Corresponding author
Gross, Megan
Venue
Scientific Reports
Published
2025-07-25
Volume
15
Issue
1
Pages
27095-27095
ISSN
2045-2322 (ISSN-L)
OpenAlex
W4412707545
Cited by
6
References
87
Citations by year
2026: 6
FWCI
1.20
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Rheinland-Pfälzische Technische Universität Kaiserslautern-Landau
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › bioluminescence and chemiluminescence research
  • Physical Sciences › Environmental Science › Ecology › Environmental DNA in Biodiversity Studies
Keywords
digital PCR, gene copy number quantification, protists, ciliates, Paramecium tetraurelia, cross-platform comparison, restriction enzymes, HaeIII, EcoRI, environmental monitoring, precision and reproducibility
MeSH terms
Reproducibility of Results, DNA, Protozoan, Polymerase Chain Reaction, Gene Dosage, DNA Copy Number Variations

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-18, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-18 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparing the precision of two digital PCR applications for copy number comparisons in protists. https://app.cochat.ai/papers/10.1038/s41598-025-13143-8
The paper
Gross, M., Stoeck, T., Mauvisseau, Q., Schrøder-Nielsen, A., & Dunthorn, M. (2025). Comparing the precision of two digital PCR applications for copy number comparisons in protists. Scientific Reports. https://doi.org/10.1038/s41598-025-13143-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.