The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Functional Hemodynamic Monitoring
Open accessAbstract
Functional hemodynamic monitoring is the assessment of the dynamic interactions of hemodynamic variables in response to a defined perturbation. Dynamic tissue O2 saturation (StO2) responses to complete stop flow conditions (vascular occlusion test), which can be created by measuring hand StO2 and occluding flow with a blood pressure cuff, assesses cardiovascular sufficiency and microcirculatory blood flow distribution. Recent interest in functional hemodynamic monitoring for the bedside assessment of cardiovascular insufficiency has heightened with the documentation of its accuracy in predicting volume responsiveness using a wide variety of monitoring devices both invasive and non-invasive and across multiple patient groups and clinical conditions. Accordingly, fluid responsiveness can be predicted in a quantities fashion by measuring as arterial pulse pressure variation, left ventricular stroke volume variation or their surrogates during positive pressure breathing or the change in cardiac output response to a passive leg raising maneuver. However, volume responsiveness, though important, reflects only part of the overall spectrum of functional physiological variables that can be measured to define physiologic state and monitor response to therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Early goal-directed therapy in the treatment of severe sepsis and septic shock
Rivers, E., Nguyen, B., Havstad, S., Ressler, J., Muzzin, A., Knoblich, B., Peterson, E., & Tomlanovich, M. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010307 · Cited by 10,743
Bur, A., Hirschl, M. M., Herkner, H., Oschatz, E., Kofler, J., Woisetschläger, C., & Laggner, A. N. (2000) · Critical Care Medicine · doi:10.1097/00003246-200002000-00014 · Cited by 154
Cited by
Bellomo, R., Ronco, C., Kellum, J. A., Mehta, R. L., Palevsky, P., & workgroup, T. A. (2004) · Critical Care · doi:10.1186/cc2872 · Cited by 6,781
Kellum, J. A., Romagnani, P., Ashuntantang, G., Ronco, C., Zarbock, A., & Anders, H.-J. (2021) · Nature Reviews Disease Primers · doi:10.1038/s41572-021-00284-z · Cited by 1,741
Calzavacca, P., Licari, E., & Bellomo, R. (2010) · Surgical Intensive Care Medicine · doi:10.1007/978-0-387-77893-8_38 · Cited by 533
Clinical review: Update on hemodynamic monitoring - a consensus of 16
Vincent, J.-L., Rhodes, A., Perel, A., Martin, G. S., Rocca, G., Vallet, B., Pinsky, M. R., Hofer, C. K., Teboul, J.-L., de Boode, W.-P., et al. (2011) · Critical Care · doi:10.1186/cc10291 · Cited by 419
Self-citationMonnet, X., Osman, D., Ridel, C., Lamia, B., Richard, C., & Teboul, J.-L. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181968fe1 · Cited by 301
Metadata
- Authors
- Pinsky, M. R.
- Venue
- Critical Care Clinics
- Publisher
- Elsevier BV
- Published
- 2015-01
- Volume
- 31
- Issue
- 1
- Pages
- 89-111
- ISSN
- 0749-0704 (ISSN-L)
- OpenAlex
- W2107330180
- Cited by
- 168
- References
- 2
- FWCI
- 6.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.