Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 301

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients

Monnet, Xavier, Osman, David, Ridel, Christophe, Lamia, Bouchra, Richard, Christian, Teboul, Jean-Louis·2009·Critical Care Medicine

Abstract

OBJECTIVE: During mechanical ventilation, inspiration cyclically decreases the left cardiac preload. Thus, an end-expiratory occlusion may prevent the cyclic impediment in left cardiac preload and may act like a fluid challenge. We tested whether this could serve as a functional test for fluid responsiveness in patients with circulatory failure. DESIGN: Prospective study. SETTING: Medical intensive care unit. PATIENTS: Thirty-four mechanically ventilated patients with shock in whom volume expansion was planned. INTERVENTION: A 15-second end-expiratory occlusion followed by a 500 mL saline infusion. MEASUREMENTS: Arterial pressure and pulse contour-derived cardiac index (PiCCOplus) at baseline, during passive leg raising (PLR), during the 5-last seconds of the end-expiratory occlusion, and after volume expansion. MAIN RESULTS: Volume expansion increased cardiac index by >15% (2.4 +/- 1.0 to 3.3 +/- 1.2 L/min/m, p < 0.05) in 23 patients ("responders"). Before volume expansion, the end-expiratory occlusion significantly increased arterial pulse pressure by 15% +/- 15% and cardiac index by 12% +/- 11% in responders whereas arterial pulse pressure and cardiac index did not change significantly in nonresponders. Fluid responsiveness was predicted by an increase in pulse pressure >or=5% during the end-expiratory occlusion with a sensitivity and a specificity of 87% and 100%, respectively, and by an increase in cardiac index >or=5% during the end-expiratory occlusion with a sensitivity and a specificity of 91% and 100%, respectively. The response of pulse pressure and cardiac index to the end-expiratory occlusion predicted fluid responsiveness with an accuracy that was similar to the response of cardiac index to PLR and that was significantly better than the response of pulse pressure to PLR (receiver operating characteristic curves area 0.957 [95% confidence interval [CI:] 0.825-0.994], 0.972 [95% CI: 0.849-0.995], 0.937 [95% CI: 0.797-0.990], and 0.675 [95% CI: 0.497-0.829], respectively). CONCLUSIONS: The hemodynamic response to an end-expiratory occlusion can predict volume responsiveness in mechanically ventilated patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e3181968fe1

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

See all 301

Metadata

Authors
Monnet, X., Osman, D., Ridel, C., Lamia, B., Richard, C., & Teboul, J.-L.
Venue
Critical Care Medicine
Published
2009-03
Volume
37
Issue
3
Pages
951-956
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2002468992
Cited by
301
References
23
FWCI
16.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients. https://app.cochat.ai/papers/10.1097/ccm.0b013e3181968fe1
The paper
Monnet, X., Osman, D., Ridel, C., Lamia, B., Richard, C., & Teboul, J.-L. (2009). Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e3181968fe1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.