Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 279

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Novel magnetic multi-templates molecularly imprinted polymer for selective and rapid removal and detection of alkylphenols in water

Xie, Xiaowen, Ma, Xiaoguo, Guo, Lihui, Fan, Yinming, Zeng, Guolong, Zhang, Mengyuan, Li, Jing·2019·Chemical Engineering Journal

Abstract

Abstract A novel multi-templates molecularly imprinted polymer (MIP) was prepared on the surface of mesoporous silica coated magnetic graphene oxide (MGO@mSiO2), and applied for the rapid and selective detection of alkylphenol compounds including bisphenol A (BPA), 4-tert-octylphenol (4-tert-OP) and 4-nonylphenol (4-NP) in water. The synthesized composite was characterized by Fourier transform infrared spectrometer, vibrating sample magnetometer, transmission electron microscopy and Brunauer-Emett-Teller surface area analyzer. The MIP showed high adsorption capacity, good selectivity and fast kinetic for these alkylphenols. The maximum adsorption capacities of the MIP for BPA, 4-tert-OP and 4-NP were 16.81, 35.97 and 61.73 mg g−1, respectively, which were significantly higher than those of the non-molecularly imprinted polymer (NIP) due to the imprinting effect. The adsorption of alkylphenols reached equilibrium within 30 min, and followed pseudo-second-order kinetic model and Langmuir model well. The MIP exhibited good sorption selectivity towards BPA, 4-tert-OP and 4-NP, and could be reused 5 times. Furthermore, a new method for ultrasensitive determination of BPA, 4-tert-OP and 4-NP in water by high performance liquid chromatography was developed, using MIP-based magnetic solid-phase extraction coupled with dispersive liquid-liquid microextraction. Under the optimum conditions, the limits of detection (LODs) for BPA, 4-tert-OP and 4-NP were 0.013, 0.010 and 0.010 μg L−1, respectively. The proposed method was used to the detection of BPA, 4-tert-OP and 4-NP in real water samples, with spiked recoveries of 81.5–104.1% and relative standard deviations (RSDs) of 1.0–7.6%, indicating the multi-templates MIP could be a promising adsorbent for separation and analysis of alkylphenols.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cej.2018.09.080

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

Metadata

Authors
Xie, X., Ma, X., Guo, L., Fan, Y., Zeng, G., Zhang, M., & Li, J.
Venue
Chemical Engineering Journal
Publisher
Elsevier BV
Published
2019-02
Volume
357
Pages
56-65
ISSN
1385-8947 (ISSN-L)
OpenAlex
W2891473039
Cited by
279
References
39
FWCI
17.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.