The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Enhanced piezoresistive performance of conductive WPU/CNT composite foam through incorporating brittle cellulose nanocrystal
Abstract
Abstract Recently, piezoresistive sensors with wide response range and high sensitivity are in great demands with the rapid development of flexible electronic industry. To meet the demands, highly compressible waterborne polyurethane (WPU)/carbon nanotube (CNT) composite foam with enhanced piezoresistive performance was designed through incorporating the brittle cellulose nanocrystal (CNC) during the fabrication process. Here, the homogeneous dispersion of CNT with the assistance of amphiphilic CNC and the good interfacial interaction between CNC and TPU endowed the composite foam with improved compression properties. In addition, the brittle CNC/CNT conductive network is easier to be destructed, generating more significant resistance variation and about as high as 2.5 times the sensitivity of composite foam without CNC. As a piezoresistive sensor, it exhibits good compressibility and stable piezoresistive sensing signal in 80% compression strain range due to the porous structure and good elasticity of WPU. Cyclic piezoresistive sensing tests under different compression strains and rates demonstrate the excellent recoverability and reproducibility of the piezoresistive sensor after the initial stabilization process. More importantly, it also displays a fast response time of about 30 ms and good durability and reproductivity over 1000 compression cycles. Finally, the piezoresistive sensor can be successfully applied to detect various human motions (such as vocal cords/cheeks/fingers/wrists/feet movements) and to fabricate artificial electronic skin. The investigation provides an effective strategy for the fabrication of high-performance piezoresistive sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A flexible and highly sensitive strain-gauge sensor using reversible interlocking of nanofibres
Pang, C., Lee, G.-Y., Kim, T.-I., Kim, S. M., Kim, H. N., Ahn, S.-H., & Suh, K.-Y. (2012) · Nature Materials · doi:10.1038/nmat3380 · Cited by 1,695
Ultrasensitive mechanical crack-based sensor inspired by the spider sensory system
Kang, D., Pikhitsa, P. V., Choi, Y. W., Lee, C., Shin, S. S., Piao, L., Park, B., Suh, K.-Y., Kim, T.-I., & Choi, M. (2014) · Nature · doi:10.1038/nature14002 · Cited by 1,626
Skin-inspired highly stretchable and conformable matrix networks for multifunctional sensing
Hua, Q., Sun, J., Liu, H., Bao, R., Yu, R., Zhai, J., Pan, C., & Wang, Z. L. (2018) · Nature Communications · doi:10.1038/s41467-017-02685-9 · Cited by 1,413
Self-citationWearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Cited by
Liu, H., Chen, X., Zheng, Y., Zhang, D., Zhao, Y., Wang, C., Pan, C., Liu, C., & Shen, C. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202008006 · Cited by 625
Self-citationZheng, Y., Yin, R., Zhao, Y., Liu, H., Zhang, D., Shi, X., Zhang, B., Liu, C., & Shen, C. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.127720 · Cited by 469
Self-citationWang, H., Zhou, R., Li, D., Zhang, L., Ren, G., Wang, L., Liu, J., Wang, D., Tang, Z., Lu, G., et al. (2021) · ACS Nano · doi:10.1021/acsnano.1c00259 · Cited by 364
Bu, Y., Shen, T., Yang, W., Yang, S., Zhao, Y., Liu, H., Zheng, Y., Liu, C., & Shen, C. (2021) · Science Bulletin · doi:10.1016/j.scib.2021.04.041 · Cited by 291
Self-citation
Metadata
- Authors
- Zhang, S., Sun, K., Liu, H., Chen, X., Zheng, Y., Shi, X., Zhang, D., Mi, L., Liu, C., & Shen, C.
- Venue
- Chemical Engineering Journal
- Publisher
- Elsevier BV
- Published
- 2020-05
- Volume
- 387
- Pages
- 124045
- ISSN
- 1385-8947 (ISSN-L)
- OpenAlex
- W2999152601
- Cited by
- 183
- References
- 4
- FWCI
- 8.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.