Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Ultrasensitive mechanical crack-based sensor inspired by the spider sensory system

Abstract

Recently developed flexible mechanosensors based on inorganic silicon, organic semiconductors, carbon nanotubes, graphene platelets, pressure-sensitive rubber and self-powered devices are highly sensitive and can be applied to human skin. However, the development of a multifunctional sensor satisfying the requirements of ultrahigh mechanosensitivity, flexibility and durability remains a challenge. In nature, spiders sense extremely small variations in mechanical stress using crack-shaped slit organs near their leg joints. Here we demonstrate that sensors based on nanoscale crack junctions and inspired by the geometry of a spider's slit organ can attain ultrahigh sensitivity and serve multiple purposes. The sensors are sensitive to strain (with a gauge factor of over 2,000 in the 0-2 per cent strain range) and vibration (with the ability to detect amplitudes of approximately 10 nanometres). The device is reversible, reproducible, durable and mechanically flexible, and can thus be easily mounted on human skin as an electronic multipixel array. The ultrahigh mechanosensitivity is attributed to the disconnection-reconnection process undergone by the zip-like nanoscale crack junctions under strain or vibration. The proposed theoretical model is consistent with experimental data that we report here. We also demonstrate that sensors based on nanoscale crack junctions are applicable to highly selective speech pattern recognition and the detection of physiological signals. The nanosca…

Overview

Integrity signals

Registry

Crossref · 10.1038/nature14002

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 24 references

Cited by

See all 1,626

Metadata

Authors
Kang, D., Pikhitsa, P. V., Choi, Y. W., Lee, C., Shin, S. S., Piao, L., Park, B., Suh, K.-Y., Kim, T.-I., & Choi, M.
Affiliations
  • Seoul National University (KR)
  • Institute for Basic Science (KR)
Corresponding author
  • Kim, Tae-il
  • Choi, Mansoo
Venue
Nature
Published
2014-12
Volume
516
Issue
7530
Pages
222-226
ISSN
  • 0028-0836 (ISSN-L)
  • 1476-4687
OpenAlex
W1989172022
Cited by
1,626
References
24
Citations by year
2026: 131 · 2025: 160 · 2024: 165 · 2023: 171 · 2022: 172 · 2021: 159 · 2020: 167 · 2019: 145 · 2018: 147 · 2017: 97 · 2016: 58 · 2015: 52 · 2014: 1
FWCI
36.00
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Nature (publishedVersion)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
Keywords
platinum thin films, flexible polymer substrates, pressure sensing, vibration sensing, speech recognition, physiological monitoring, skin-mounted sensors, self-powered devices
MeSH terms
Animals, Humans, Movement, Music, Pattern Recognition, Automated, Platinum, Pressure, Skin, Sound, Speech, Spiders, Vibration, Wings, Animal, Pliability, Biomimetics, Nanotechnology, Mechanotransduction, Cellular

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasensitive mechanical crack-based sensor inspired by the spider sensory system. https://app.cochat.ai/papers/10.1038/nature14002
The paper
Kang, D., Pikhitsa, P. V., Choi, Y. W., Lee, C., Shin, S. S., Piao, L., Park, B., Suh, K.-Y., Kim, T.-I., & Choi, M. (2014). Ultrasensitive mechanical crack-based sensor inspired by the spider sensory system. Nature. https://doi.org/10.1038/nature14002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.