Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 174

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Robust and sensitive pressure/strain sensors from solution processable composite hydrogels enhanced by hollow-structured conducting polymers

Zhou, Hongwei, Wang, Zhiwen, Zhao, Weifeng, Tong, Ximan, Jin, Xilang, Zhang, Xingcai, Yu, You, Liu, Hanbin, Ma, Yichao, Li, Shushu, Chen, Weixing · 2021 · Chemical Engineering Journal

Abstract

Abstract Flexible sensors based on conductive hydrogels have found potential applications in many emerging electronic devices, but they often suffer from poor mechanical properties, single response mode and low sensitivity. Herein, robust and sensitive pressure/strain sensors are designed and fabricated utilizing novel composite hydrogels composed of hollow polyaniline spheres (HPS), poly(vinyl alcohol) (PVA) and phytic acid (PA). By taking advantages of structure-derived elasticity of hollow spheres, conductivity of doped conducting polymers, flexibility of polymer matrix and physically cross-linked structure, the composite hydrogels exhibit outstanding mechanical properties, strain sensitivity, piezoresistivity and solution processability. The optimized composite hydrogel possesses high tensile strength (9.3 MPa), stretchability (>493%) and toughness (2.6 MJ/m3). Resistive-type strain sensors assembled from the composite hydrogel can achieve a gauge factor (GF) of 2.9 in the strain range of 0%~300%, a GF of 7.4 in the strain range of 300%–450%, a response time of 0.22 s and high reliability (1000 cycles). Capacitive-type pressure sensor with ultrahigh sensitivity of GF = 3.6 kPa−1 is fabricated by sandwiching a dielectric layer between two composite hydrogel films. Interestingly, piezoresistivity of such composite hydrogels makes them promising materials for piezoresistive-type pressure sensors and visualization of pressure. On the basis of their high performances, flexible sensors of the composite hydrogels are applied in monitoring various human motions, physiological activities and bending/vibration deformations in daily life.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cej.2020.126307

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 174

Metadata

Authors
Zhou, H., Wang, Z., Zhao, W., Tong, X., Jin, X., Zhang, X., Yu, Y., Liu, H., Ma, Y., Li, S., & Chen, W.
Venue
Chemical Engineering Journal
Publisher
Elsevier BV
Published
2021-01
Volume
403
Pages
126307
ISSN
1385-8947 (ISSN-L)
OpenAlex
W3043249843
Cited by
174
References
7
FWCI
7.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Robust and sensitive pressure/strain sensors from solution processable composite hydrogels enhanced by hollow-structured conducting polymers. https://app.cochat.ai/papers/10.1016/j.cej.2020.126307
The paper
Zhou, H., Wang, Z., Zhao, W., Tong, X., Jin, X., Zhang, X., Yu, Y., Liu, H., Ma, Y., Li, S., & Chen, W. (2021). Robust and sensitive pressure/strain sensors from solution processable composite hydrogels enhanced by hollow-structured conducting polymers. Chemical Engineering Journal. https://doi.org/10.1016/j.cej.2020.126307

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.