Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 345

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Anti-freezing, resilient and tough hydrogels for sensitive and large-range strain and pressure sensors

Yang, Yanyu, Yang, Yatian, Cao, Yanxia, Wang, Xing, Chen, Yourong, Liu, Hongyan, Gao, Yafei, Wang, Jianfeng, Liu, Chao, Wang, Wanjie, Yu, Jia-Kuo, Wu, Decheng·2021·Chemical Engineering Journal

Abstract

Abstract Hydrogel sensors are peculiarly attractive in flexible wearable electronics due to the stretchability and strain-responsive ability. However, flexible sensors (e.g. electronic skin) in practice require to perceive both strain and pressure concurrently and repeatedly, which put forward an imperative demand for multi-model and durable hydrogel sensors. Additionally, freezing intolerance is also an urgent problem to be addressed for low-temperature applications of hydrogel sensors. Herein, we constructed a wearable multi-model hydrogel sensor featuring with sensitive and large-range strain and pressure detection capacity, together with long-term stability and wide operating temperature range, based on a resilient, anti-fatigue and freezing-tolerant chitosan-poly(hydroxyethyl acrylamide) double-network (CS-PHEAA DN) hydrogel, which was fabricated via post-crosslinking CS-PHEAA composite hydrogel into Na3Cit solution. The ions simultaneously furnished the hydrogel with superior mechanics (stretchability, supercompressibility, excellent resilience and remarkable fatigue resistance), prominent ionic conductivity and low temperature tolerance. Impressively, the assembled hydrogel sensor exhibited preeminent sensitivity and cycling stability on detecting multi-type and large-range deformation (elongation, compression and bend), pressure and various human motions even at low temperatures. Remarkably, the fabricated hydrogel/aluminum hybrid combination serving as a flexible sensor maintained mechanical advantages, sensitive sensing capacity and good durability within a wide temperature range. This work provides a feasible method to construct anti-freezing, durable and multi-mode hydrogel sensors with high sensitivity and large-range detection capacity and paves a way for versatile applications in electronic skin, human-motion detection and intelligence device.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cej.2020.126431

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 38 references

Cited by

See all 345

Metadata

Authors
Yang, Y., Yang, Y., Cao, Y., Wang, X., Chen, Y., Liu, H., Gao, Y., Wang, J., Liu, C., Wang, W., Yu, J.-K., & Wu, D.
Venue
Chemical Engineering Journal
Publisher
Elsevier BV
Published
2021-01
Volume
403
Pages
126431
ISSN
1385-8947 (ISSN-L)
OpenAlex
W3043959317
Cited by
345
References
38
FWCI
15.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Anti-freezing, resilient and tough hydrogels for sensitive and large-range strain and pressure sensors. https://app.cochat.ai/papers/10.1016/j.cej.2020.126431
The paper
Yang, Y., Yang, Y., Cao, Y., Wang, X., Chen, Y., Liu, H., Gao, Y., Wang, J., Liu, C., Wang, W., Yu, J.-K., & Wu, D. (2021). Anti-freezing, resilient and tough hydrogels for sensitive and large-range strain and pressure sensors. Chemical Engineering Journal. https://doi.org/10.1016/j.cej.2020.126431

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.