The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
3D experimental investigation of the microstructure of cement pastes using synchrotron X-ray microtomography (μCT)
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Interfacial Transition Zone (ITZ) Between Cement Paste and Aggregate in Concrete
Scrivener, K. L., Crumbie, A. K., & Laugesen, P. (2004) · Interface Science · doi:10.1023/b:ints.0000042339.92990.4c · Cited by 1,460
Self-citationBackscattered electron imaging of cementitious microstructures: understanding and quantification
Scrivener, K. L. (2004) · Cement and Concrete Composites · doi:10.1016/j.cemconcomp.2004.02.029 · Cited by 894
Self-citationThree-Dimensional X-Ray Microtomography
Flannery, B. P., Deckman, H. W., Roberge, W. G., & D'Amico, K. L. (1987) · Science · doi:10.1126/science.237.4821.1439 · Cited by 773
Scrivener, K. L., Füllmann, T., Gallucci, E., Walenta, G., & Bermejo, E. (2004) · Cement and Concrete Research · doi:10.1016/j.cemconres.2004.04.014 · Cited by 565
Self-citationUsing X-ray computed tomography in hydrology: systems, resolutions, and limitations
Wildenschild, D., Vaz, C. M. P., Rivers, M. L., Rikard, D., & Christensen, B. S. B. (2002) · Journal of Hydrology · doi:10.1016/s0022-1694(02)00157-9 · Cited by 528
Simulation of Cement Hydration and the Connectivity of the Capillary Pore Space
Navi, P., & Pignat, C. (1996) · Advanced Cement Based Materials · doi:10.1016/s1065-7355(96)90052-8 · Cited by 155
High resolution X-ray detector for synchrotron-based microtomography
Stampanoni, M., Borchert, G. L., Wyss, P., Abela, R., Patterson, B. D., Hunt, S., Vermeulen, D., & Ruegsegger, P. (2002) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(02)01167-1 · Cited by 145
Self-citationMicrostructure and transport properties of porous building materials
Quenard, D. A., Xu, K., Künzel, H. M., Bentz, D. P., & Martys, N. (1998) · Materials and Structures · doi:10.1007/bf02480673 · Cited by 73
Cited by
Technical and commercial progress in the adoption of geopolymer cement
Van Deventer, J. S. J., Provis, J. L., & Duxson, P. (2012) · Minerals Engineering · doi:10.1016/j.mineng.2011.09.009 · Cited by 820
X-ray microtomography shows pore structure and tortuosity in alkali-activated binders
Provis, J. L., Myers, R. J., White, C. E., Rose, V., & van Deventer, J. S. J. (2012) · Cement and Concrete Research · doi:10.1016/j.cemconres.2012.03.004 · Cited by 572
Multiscale X-ray tomography of cementitious materials: A review
Brisard, S., Serdar, M., & Monteiro, P. J. M. (2020) · Cement and Concrete Research · doi:10.1016/j.cemconres.2019.105824 · Cited by 260
Cuesta, A., De la Torre, A. G., Santacruz, I., Trtik, P., da Silva, J. C., Diaz, A., Holler, M., & Aranda, M. A. G. (2017) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.6b10048 · Cited by 55
Metadata
- Authors
- Gallucci, E., Scrivener, K., Groso, A., Stampanoni, M., & Margaritondo, G.
- Venue
- Cement and Concrete Research
- Publisher
- Elsevier BV
- Published
- 2007-03
- Volume
- 37
- Issue
- 3
- Pages
- 360-368
- ISSN
- 0008-8846 (ISSN-L)
- OpenAlex
- W2044210764
- Cited by
- 363
- References
- 8
- FWCI
- 23.19
- Type
- journal article
- Language
- en
- Status
- Retracted
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.