The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Three-Dimensional X-Ray Microtomography
Abstract
The new technique of x-ray microtomography nondestructively generates three-dimensional maps of the x-ray attenuation coefficient inside small samples with approximately 1 percent accuracy and with resolution approaching 1 micrometer. Spatially resolved elemental maps can be produced with synchrotron x-ray sources by scanning samples at energies just above and below characteristic atomic absorption edges. The system consists of a high-resolution imaging x-ray detector and high-speed algorithms for tomographic image reconstruction. The design and operation of the microtomography device are described, and tomographic images that illustrate its performance with both synchrotron and laboratory x-ray sources are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computerized transverse axial scanning (tomography): Part 1. Description of system
Hounsfield, G. N. (1973) · The British Journal of Radiology · doi:10.1259/0007-1285-46-552-1016 · Cited by 3,924
The Fourier reconstruction of a head section
Shepp, L. A., & Logan, B. F. (1974) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1974.6499235 · Cited by 2,179
Representation of a Function by Its Line Integrals, with Some Radiological Applications
Cormack, A. M. (1963) · Journal of Applied Physics · doi:10.1063/1.1729798 · Cited by 1,399
Strip Integration in Radio Astronomy
Bracewell, R. (1956) · Australian Journal of Physics · doi:10.1071/ph560198 · Cited by 682
Digital reconstruction of multidimensional signals from their projections
Mersereau, R. M., & Oppenheim, A. V. (1974) · Proceedings of the IEEE · doi:10.1109/proc.1974.9625 · Cited by 435
Optimum energies for x-ray transmission tomography of small samples
Grodzins, L. (1983) · Nuclear Instruments and Methods in Physics Research · doi:10.1016/0167-5087(83)90393-9 · Cited by 252
Cited by
Landis, E. N., & Keane, D. T. (2010) · Materials Characterization · doi:10.1016/j.matchar.2010.09.012 · Cited by 608
High resolution X-ray computed tomography: an emerging tool for small animal cancer research
Paulus, M. J., Gleason, S. S., Kennel, S. J., Hunsicker, P. R., & Johnson, D. K. (2000) · Neoplasia · doi:10.1038/sj.neo.7900069 · Cited by 490
Helliwell, J. R., Sturrock, C. J., Grayling, K. M., Tracy, S. R., Flavel, R. J., Young, I. M., Whalley, W. R., & Mooney, S. J. (2013) · European Journal of Soil Science · doi:10.1111/ejss.12028 · Cited by 225
Metadata
- Authors
- Flannery, B. P., Deckman, H. W., Roberge, W. G., & D'Amico, K. L.
- Venue
- Science
- Published
- 1987-09-18
- Volume
- 237
- Issue
- 4821
- Pages
- 1439-1444
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2014947933
- Cited by
- 773
- References
- 6
- FWCI
- 29.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-Dimensional X-Ray Microtomography. https://app.cochat.ai/papers/10.1126/science.237.4821.1439
- The paper
- Flannery, B. P., Deckman, H. W., Roberge, W. G., & D'Amico, K. L. (1987). Three-Dimensional X-Ray Microtomography. Science. https://doi.org/10.1126/science.237.4821.1439
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.