Magnesium incorporated hydroxyapatite: Synthesis and structural properties characterization
Open accessThe DOI matches its Crossref record.
Abstract
Synthetic hydroxyapatites are widely used in bone tissue engineering because of their similar composition with the inorganic phase of hard tissues. Biological apatites, however, are calcium-deficient apatites with many di- and tri-valent ion substitutions. In this study, stoichiometric hydroxyapatite (HA) powders were prepared by wet-chemical precipitation method, and the effect of Mg incorporation on the resulting solid solution was investigated. X-ray diffraction (XRD) analysis confirmed that the substitution of Mg for Ca in apatite lattice resulted in a slight increase in a lattice and more emphasized decrease in c lattice parameters: 0.0966% and 0.2964%, respectively. The results indicated an increase in the d-spacing of Mg-doped HA (MHA). Scanning electron microscopy–energy dispersive X-ray spectroscopy (SEM–EDX) analysis showed that the Mg, C, and O elements were evenly distributed. Transmission electron microscopy (TEM) analysis revealed that incorporation of Mg did not significantly alter the size of the precipitated crystals. Although XRD patterns suggested smaller crystallite size, such a result was still consistent with TEM results, wherein change in size was not significant in Mg-doped HA (MHA) in comparison to HA. Moreover, the incorporation of impurity ions into the HA lattice did not alter the high-temperature phase stability often required for processing. The comparison of HA and MHA samples before and after heat treatment showed that the apatite structure did not decompose or undergo any phase transformation at high temperatures. A proportion of the Mg added did not substitute into the HA lattice. The Mg(OH)2 phase, as observed in the XRD pattern of the Mg-added sample, was a second phase that was easily washed by a citrate solution. In both HA and MHA samples, the calcium phosphate phase remained as a single-phase hexagonal calcium hydroxyapatite before and after heat treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Design and characterization of calcium phosphate ceramic scaffolds for bone tissue engineering
Denry, I., & Kuhn, L. T. (2016) · Dental Materials · doi:10.1016/j.dental.2015.09.008 · Cited by 259
Ionic substituted hydroxyapatite for bone regeneration applications: A review
Ressler, A., Žužić, A., Ivanišević, I., Kamboj, N., & Ivanković, H. (2021) · Open Ceramics · doi:10.1016/j.oceram.2021.100122 · Cited by 254
Enhancing bioactivity of hydroxyapatite scaffolds using fibrous type I collagen
Nitti, P., Kunjalukkal Padmanabhan, S., Cortazzi, S., Stanca, E., Siculella, L., Licciulli, A., & Demitri, C. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.631177 · Cited by 35
Almeida, C. L., Figueiredo, L. R. F., Melo, J. D. D., & Medeiros, E. S. (2025) · ACS Omega · doi:10.1021/acsomega.5c06418 · Cited by 1
Metadata
- Authors
- Farzadi, A., Bakhshi, F., Solati-Hashjin, M., Asadi-Eydivand, M., & Osman, N. A. A.
- Venue
- Ceramics International
- Publisher
- Elsevier BV
- Published
- 2014-05
- Volume
- 40
- Issue
- 4
- Pages
- 6021-6029
- ISSN
- 0272-8842 (ISSN-L)
- OpenAlex
- W1967335581
- Cited by
- 243
- References
- 0
- FWCI
- 4.25
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnesium incorporated hydroxyapatite: Synthesis and structural properties characterization. https://app.cochat.ai/papers/10.1016/j.ceramint.2013.11.051
- The paper
- Farzadi, A., Bakhshi, F., Solati-Hashjin, M., Asadi-Eydivand, M., & Osman, N. A. A. (2014). Magnesium incorporated hydroxyapatite: Synthesis and structural properties characterization. Ceramics International. https://doi.org/10.1016/j.ceramint.2013.11.051
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.