Selective protein quantification for preparative chromatography using variable pathlength UV/Vis spectroscopy and partial least squares regression
Open accessThe DOI matches its Crossref record.
Abstract
In preparative protein chromatography, broad dynamic ranges of protein concentrations as well as co-elution of product and impurities are common. Despite being the standard in biopharmaceutical production, monitoring of preparative chromatography is generally limited to surrogate signals, e.g. UV absorbance at 280 nm. To address this problem, variable pathlength (VP) spectroscopy in conjunction with Partial Least Squares regression (PLS) was used to monitor preparative chromatography. While VP spectroscopy enabled the acquisition of absorbance data for a broad concentration range, PLS modelling allowed for the differentiation between the protein species. The approach was first implemented for monitoring the separation of lysozyme from cytochrome c at an overall loading density of 92 g/l. The same method was then applied to the polishing step of a monoclonal antibody (mAb) at 40 g/l loading density. For PLS model prediction of the mAb monomer and the high molecular weight variants (HMWs), the root mean square error (RMSE) was 1.07 g/l and 0.42 g/l respectively. To demonstrate the usability of the approach for in-line control, pooling decisions for both separation problems were subsequently taken based on the computed concentrations or thereof derived purities. In summary, VP spectroscopy in conjunction with PLS modelling is a promising option for in-line monitoring and control of future chromatography steps at large scale.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wasalathanthri, D. P., Rehmann, M. S., Song, Y., Gu, Y., Mi, L., Shao, C., Chemmalil, L., Lee, J., Ghose, S., Borys, M. C., et al. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27461 · Cited by 177
Rolinger, L., Rüdt, M., & Hubbuch, J. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02407-z · Cited by 126
Self-citationGoldrick, S., Umprecht, A., Tang, A., Zakrzewski, R., Cheeks, M., Turner, R., Charles, A., Les, K., Hulley, M., Spencer, C., et al. (2020) · Processes · doi:10.3390/pr8091179 · Cited by 48
“UV spectroscopy has been also shown to monitor mAb aggregate and monomer concentrations [35], although during the investigated runs the monomer and aggregate peaks showed a good separation, which might not always be the case and could decrease the otherwise high sensitivity of predictions.”
BackgroundWang, J., Chen, J., Studts, J., & Wang, G. (2023) · mAbs · doi:10.1080/19420862.2023.2220149 · Cited by 37
“We used a value of 2 for the number of latent variables used by the PCR and PLS models based on values used in previous studies.(21)”
BackgroundMethodRolinger, L., Rüdt, M., & Hubbuch, J. (2021) · Biotechnology and Bioengineering · doi:10.1002/bit.27894 · Cited by 33
Self-citationIn‐Line Monitoring of Protein Concentration With MIR Spectroscopy During UFDF
Milewska, A., Baekelandt, G., Boutaieb, S., Mozin, V., & Falconbridge, A. (2023) · Engineering in Life Sciences · doi:10.1002/elsc.202200050 · Cited by 18
Westwood, F., Ponstingl, M., & Dickens, J. E. (2024) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2024.115965 · Cited by 4
Metadata
- Authors
- Brestrich, N., Rüdt, M., Büchler, D., & Hubbuch, J.
- Venue
- Chemical Engineering Science
- Publisher
- Elsevier BV
- Published
- 2018-02
- Volume
- 176
- Pages
- 157-164
- ISSN
- 0009-2509 (ISSN-L)
- OpenAlex
- W2765137641
- Cited by
- 68
- References
- 0
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.