Cited by 17

In‐Line Monitoring of Protein Concentration With MIR Spectroscopy During UFDF

Milewska, Adrianna, Baekelandt, Géraldine, Boutaieb, Sarra, Mozin, Vitalii, Falconbridge, Andrew·2023·Engineering in Life Sciences

Abstract

Rapid increase of product titers in upstream processes has presented challenges for downstream processing, where purification costs increase linearly with the increase of the product yield. Hence, innovative solutions are becoming increasingly popular. Process Analytical Technology (PAT) tools, such as spectroscopic techniques, are on the rise due to their capacity to provide real‐time, precise analytics. This ensures consistent product quality and increased process understanding, as well as process control. Mid‐infrared spectroscopy (MIR) has emerged as a highly promising technique within recent years, owing to its ability to monitor several critical process parameters at the same time and unchallenging spectral analysis and data interpretation. For in‐line monitoring, Attenuated Total Reflectance—Fourier Transform Infrared Spectroscopy (ATR‐FTIR) is a method of choice, as it enables reliable measurements in a liquid environment, even though water absorption bands are present in the region of interest. Here, we present MIR spectroscopy as a monitoring tool of critical process parameters in ultrafiltration/diafiltration (UFDF). MIR spectrometer was integrated in the UFDF process in an in‐line fashion through a single‐use flow cell containing a single bounce silicon ATR crystal. The results indicate that the one‐point calibration algorithm applied to the MIR spectra, predicts highly accurate protein concentrations, as compared with validated offline analytical methods.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/elsc.202200050

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • ATR-FTIR has been implemented in-line during the UFDF step to monitor protein concentration with a simple one-point calibration algorithm or both protein and various excipient concentrations with a multivariate data analysis model.

    “Recently, ATR‐FTIR has also been implemented in‐line during the UFDF step, to monitor the protein concentration with a simple one‐point calibration algorithm [55] or both protein and various excipient concentrations, with a multi‐variate data analysis (MVDA) model [56].”
  • In ATR-FTIR monitoring during UFDF, rapid measurements in seconds and accurate concentration predictions were achieved.

    “In both cases, rapid measurements in seconds and accurate concentration predictions were achieved.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 28

  1. [1]Gerzon G, Sheng Y, Kirkitadze M. Process analytical technologies ‐ advances in bioprocess integration and future perspectives. J Pharm Biomed Anal. 2022; 207: 114379. 10.1016/j.jpba.2021.114379 34607168 · DOI
  2. [2]Challa S, Potumarthi R. Chemometrics‐based process analytical technology (PAT) tools: applications and adaptation in pharmaceutical and biopharmaceutical industries. Appl Biochem Biotechnol. 2013; 169(1): 66‐ 76. 10.1007/s12010-012-9950-y 23138336 · DOI
  3. [3]Gross PC, Zeppezauer M. Infrared spectroscopy for biopharmaceutical protein analysis. J Pharm Biomed Anal. 2010; 53(1): 29‐ 36. 10.1016/j.jpba.2010.03.009 20381986 · DOI
  4. [4]Chemmalil L, Prabhakar T, Kuang J, et al. Online/at‐line measurement, analysis and control of product titer and critical product quality attributes (CQAs) during process development. Biotechnol Bioeng. 2020; 117(12): 3757‐ 3765. 10.1002/bit.27531 32776503 · DOI
  5. [5]Sandor M, Rüdinger F, Solle D, et al. NIR‐spectroscopy for bioprocess monitoring & control. BMC Proc. 2013; 7(S6): P29. 10.1186/1753-6561-7-s6-p29 · DOI
  6. [7]Langer ERJ. Capacity bottleneck squeezed by downstream processes. Bioprocess Int. 2006; 4: 14‐ 17.
  7. [8]Gronemeyer P, Ditz R, Strube J. Trends in upstream and downstream process development for antibody manufacturing. Bioengineering (Basel). 2014; 1(4): 188‐ 212. 10.3390/bioengineering1040188 28955024 · DOI
  8. [9]Ichihara T, Ito T, Kurisu Y, Galipeau K, Gillespie C. Integrated flow‐through purification for therapeutic monoclonal antibodies processing. MAbs. 2018; 10(2): 325‐ 334. 10.1080/19420862.2017.1417717 29271693 PMC5825194 · DOI
  9. [10]Rolinger L, Rudt M, Diehm J, et al. Multi‐attribute PAT for UF/DF of proteins‐monitoring concentration, particle sizes, and buffer exchange. Anal Bioanal Chem. 2020; 412(9): 2123‐ 2136. 10.1007/s00216-019-02318-8 32072210 · DOI · Paper page
  10. [11]Briskot T, Hillebrandt N, Kluters S, et al. Modeling the Gibbs‐Donnan effect during ultrafiltration and diafiltration processes using the Poisson‐Boltzmann theory in combination with a basic Stern model. J Membr Sci. 2022; 648: 120333. https://ARTN.120333.10.1016/j.memsci.2022.120333 · DOI
  11. [12]Callahan DJ, Stanley B, Li YL. Control of protein particle formation during ultrafiltration/diafiltration through interfacial protection. J Pharm Sci. 2014; 103(3): 862‐ 869. 10.1002/jps.23861 24449131 PMC4284022 · DOI
  12. [13]Chanda A, Daly AM, Foley DA, et al. Industry perspectives on process analytical technology: tools and applications in API development. Org Process Res Dev. 2014; 19(1): 63‐ 83. 10.1021/op400358b · DOI
  13. [14]Clegg I. Chapter 7 ‐ Process analytical technology. Specification of Drug Substances and Products. 2nd ed. Development and Validation of Analytical Methods; 2020: 149‐ 173. 10.1016/B978-0-08-102824-7.00007-5 · DOI
  14. [15]Brestrich N, Rüdt M, Büchler D, Hubbuch J. Selective protein quantification for preparative chromatography using variable pathlength UV/Vis spectroscopy and partial least squares regression. Chem Eng Sci. 2018; 176: 157‐ 164. 10.1016/j.ces.2017.10.030 · DOI
  15. [16]Gillespie C, Wasalathanthri DP, Ritz DB, et al. Systematic assessment of process analytical technologies for biologics. Biotechnol Bioeng. 2022; 119(2): 423‐ 434. 10.1002/bit.27990 34778948 · DOI
  16. [17]Deidda R, Sacre P‐Y, Clavaud M, et al. Vibrational spectroscopy in analysis of pharmaceuticals: critical review of innovative portable and handheld NIR and Raman spectrophotometers. TrAC, Trends Anal Chem. 2019; 114: 251‐ 259. 10.1016/j.trac.2019.02.035 · DOI
  17. [18]Abu‐Absi NR, Martel RP, Lanza AM, Clements SJ, Borys MC, Li ZJ. Application of spectroscopic methods for monitoring of bioprocesses and the implications for the manufacture of biologics. Pharm Bioprocess. 2014; 2(3): 267‐ 284. 10.4155/pbp.14.24 · DOI
  18. [19]Türker‐Kaya S, Huck CW. A review of mid‐infrared and near‐infrared imaging: principles, concepts and applications in plant tissue analysis. Molecules. 2017; 22(1): 168. 10.3390/molecules22010168 28117673 PMC6155813 · DOI
  19. [20]Capito F, Skudas R, Kolmar H, Hunzinger C. At‐line mid infrared spectroscopy for monitoring downstream processing unit operations. Process Biochem. 2015; 50(6): 997‐ 1005. 10.1016/j.procbio.2015.03.005 · DOI
  20. [21]Wasalathanthri DP, Feroz H, Puri N, et al. Real‐time monitoring of quality attributes by in‐line Fourier transform infrared spectroscopic sensors at ultrafiltration and diafiltration of bioprocess. Biotechnol Bioeng. 2020; 117(12): 3766‐ 3774. 10.1002/bit.27532 32776504 · DOI · Paper page
  21. [22]Yang H, Yang S, Kong J, Dong A, Yu S. Obtaining information about protein secondary structures in aqueous solution using Fourier transform IR spectroscopy. Nat Protoc. 2015; 10(3): 382‐ 396. 10.1038/nprot.2015.024 25654756 · DOI
  22. [24]Boulet‐Audet M, Byrne B, Kazarian SG. High‐throughput thermal stability analysis of a monoclonal antibody by attenuated total reflection FT‐IR spectroscopic imaging. Anal Chem. 2014; 86(19): 9786‐ 9793. 10.1021/ac502529q 25221926 PMC4218712 · DOI
  23. [25]Boulet‐Audet M, Byrne B, Kazarian SG. Cleaning‐in‐place of immunoaffinity resins monitored by in situ ATR‐FTIR spectroscopy. Anal Bioanal Chem. 2015; 407(23): 7111‐ 7122. 10.1007/s00216-015-8871-3 26159572 PMC4551555 · DOI
  24. [27]Joly M, Deng T, Morhart TA, et al. Scanning aperture approach for spatially selective ATR‐FTIR spectroscopy: application to microfluidics. Anal Chem. 2021; 93(42): 14076‐ 14087. 10.1021/acs.analchem.1c01614 34636233 · DOI
  25. [28]Barth A. Infrared spectroscopy of proteins. Biochim Biophys Acta. 2007; 1767(9): 1073‐ 1101. 10.1016/j.bbabio.2007.06.004 17692815 · DOI · Paper page
  26. [29]Mallamace F, Corsaro C, Mallamace D, Vasi S, Vasi C, Dugo G. The role of water in protein's behavior: the two dynamical crossovers studied by NMR and FTIR techniques. Comput Struct Biotechnol J. 2015; 13: 33‐ 37. 10.1016/j.csbj.2014.11.007 25750698 PMC4348435 · DOI
  27. [30]Sritham E, Gunasekaran S. FTIR spectroscopic evaluation of sucrose‐maltodextrin‐sodium citrate bioglass. Food Hydrocolloids. 2017; 70: 371‐ 382. 10.1016/j.foodhyd.2017.04.023 · DOI
  28. [31]Mayerhofer TG, Pipa AV, Popp J. Beer's law‐why integrated absorbance depends linearly on concentration. ChemPhysChem. 2019; 20(21): 2748‐ 2753. 10.1002/cphc.201900787 31544999 PMC6899465 · DOI · Paper page

Cited by

Sorted by citations

Authors
Milewska, A., Baekelandt, G., Boutaieb, S., Mozin, V., & Falconbridge, A.
Affiliations
  • Alvotech Reykjavík Iceland
  • IRUBIS GmbH München Germany
Venue
Engineering in Life Sciences
Publisher
Wiley
Published
2022-12-23
Volume
23
Issue
2
ISSN
  • 1618-0240
  • 1618-2863
Cited by
17
References
1
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review