Diagnostic Performance of Measurement of Fecal Elastase-1 in Detection of Exocrine Pancreatic Insufficiency: Systematic Review and Meta-analysis
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
BACKGROUND & AIMS Tests to quantify fecal levels of chymotrypsin like elastase family member 3 (CELA3 or elastase‐1) in feces are widely used to identify patients with exocrine pancreatic insufficiency (EPI). However, the diagnostic accuracy of this test, an ELISA, is not clear. We performed a systematic review and meta‐analysis to determine the accuracy of measurement of fecal elastase‐1 in detection of EPI. METHODS We searched PubMed, Embase, and reference lists for articles through November 2016 describing studies that compared fecal level of elastase‐1 with results from a reference standard, direct method (secretin stimulation test), or indirect method (measurement of fecal fat) for detection of EPI. Sensitivity and specificity values were pooled statistically using bivariate diagnostic meta–analysis. RESULTS We included total of 428 cases of EPI and 673 individuals without EPI (controls), from 14 studies, in the meta‐analysis. The assay for elastase‐1, compared to secretin stimulation test, identified patients with pancreatic insufficiency with a pooled sensitivity value of 0.77 (95% CI, 0.58–0.89) and specificity value of 0.88 (95% CI, 0.78–0.93). In an analysis of 345 cases of EPI and 312 controls, from 6 studies, the fecal elastase‐1 assay identified patients with EPI with a pooled sensitivity value of 0.96 (95% CI, 0.79–0.99) and specificity value of 0.88 (95% CI, 0.59–0.97), compared to quantitative fecal fat estimation. In patients with low pre–test probability of EPI (5%), the fecal elastase‐1 assay would have a false‐negative rate of 1.1% and a false‐positive rate of 11%, indicating a high yield in ruling out EPI but not in detection of EPI. In contrast, in patients with high pre‐test probability of EPI (40%), approximately 10% of patients with EPI would be missed (false negatives). CONCLUSIONS In a systematic review and meta‐analysis of studies that compared fecal level of elastase‐1 for detection of EPI, we found that normal level of elastase‐1 (above 200 mcg/g) can rule out EPI in patients with a low probability of this disorder (such as those with irritable bowel syndrome with diarrhea). However, in these patients, an abnormal level of elastase‐1 (below 200 mcg/g) has a high false‐positive rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & The PRISMA Group (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000097 · Cited by 64,042
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Wang, G., Ma, R., Qiao, G., Wada, K., Aizawa, Y., & Satoh, T. (2015) · Integrative Medicine International · doi:10.1159/000368408 · Cited by 18,657
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199 · cited 1×
“We used the Quality Assessment of Diagnostic Accuracy Studies tool to assess the risk of bias in 4 domains regarding participant selection, index test, target condition, reference standard, and flow and timing.(24) Two authors (R.”
RAPID METHOD FOR THE DETERMINATION OF FAT IN FECES
van de Kamer, J. H., Huinink, H. T. B., & Weyers, H. A. (1949) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)57092-7 · Cited by 1,845 · cited 2×
“In the 72-hour fecal fat analysis, steatorrhea was defined as>7 g fat excretion per day using the Va de Kamer method.(11)”
Relations between Pancreatic Enzyme Outputs and Malabsorption in Severe Pancreatic Insufficiency
DiMagno, E. P., Go, V. L. W., & Summerskill, W. H. J. (1973) · New England Journal of Medicine · doi:10.1056/nejm197304192881603 · Cited by 934
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W., Westwood, M. E., Mallett, S. V., Deeks, J. J., Reitsma, J. B., Leeflang, M., Sterne, J. A. C., & Bossuyt, P. M. (2011) · Data Archiving and Networked Services (DANS) · doi:10.1059/0003-4819-155-8-201110180-00009 · Cited by 601
Faecal elastase 1: a novel, highly sensitive, and specific tubeless pancreatic function test.
Löser, C., Möllgaard, A., & Fölsch, U. R. (1996) · Gut · doi:10.1136/gut.39.4.580 · Cited by 554 · cited 5×
“Sensitivity and Specificity of Fecal Elastase-1 Versus Secretin Stimulation Test in Individual Studies of Patients With Moderate Exocrine Pancreatic Insufficiency Study (ref) Cases (n) Control subjects (n) Sensitivity Specificity Loser9 14 85 1.00 0.93 Lankish35 9 34 0.33 0.94 Hahn23 5 20 0.40 0.80 Luth28 14 65 0.86 0…”
InfluentialHuman pancreatic exocrine response to nutrients in health and disease
Keller, J., & Layer, P. (2005) · Gut · doi:10.1136/gut.2005.065946 · Cited by 551 · cited 1×
“027 Progressive depletion of pancreatic acinar cells leads to exocrinepancreatic insufficiency (EPI), defined as an insufficient amount of pancreatic enzymes resulting in fat malabsorption.(1) Steatorrhea generally does not occur until lipase secretion is reduced by >90%.”
Immunoreactive elastase I: clinical evaluation of a new noninvasive test of pancreatic function
Stein, J., Jung, M., Sziegoleit, A., Zeuzem, S., Caspary, W. F., & Lembcke, B. (1996) · Clinical Chemistry · doi:10.1093/clinchem/42.2.222 · Cited by 229 · cited 4×
“Fecal chymotrypsin assays are limited in that chymotrypsin is prone to proteolytic degradation and the assay cannot differentiate the exogenous chymotrypsin found in pancreatic enzyme supplements.(10) Quantitative (72-hour) fecal fat estimation is considered the gold standard among the indirect pancreatic function tes…”
InfluentialLankisch, P. G., Schmidt, I., König, H., Lehnick, D., Knollmann, R., Löhr, M., & Liebe, S. (1998) · Gut · doi:10.1136/gut.42.4.551 · Cited by 185 · cited 2×
“…Soldan 1997 High risk Low risk Low risk Low risk Low risk Low risk Low risk Loser 1998 High risk Low risk Low risk Unknown Low risk Low risk Low risk Lankisch 1998 Low risk Low risk Low risk Unknown Low risk Low risk Low risk Walkowiak 1999 High risk Low risk Low risk Unknown Low risk Low risk Low…”
Die diagnostische Validität nichtinvasiver Pankreasfunktionstests - Eine Metaanalyse
Siegmund, E., Löhr, M. J., & Schuff‐Werner, P. (2004) · Zeitschrift für Gastroenterologie · doi:10.1055/s-2004-813604 · Cited by 129
Management of pancreatic exocrine insufficiency: Australasian Pancreatic Club recommendations
Toouli, J., Biankin, A. V., Oliver, M. R., Pearce, C. B., Wilson, J. S., & Wray, N. H. (2010) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.2010.tb04000.x · Cited by 124 · cited 1×
“Clinicians frequently use empiric trial of pancreatic enzyme replacement and use patient-reported reduction in steatorrhea to establish EPI diagnosis.(7) However, this is not ideal because of availability of different formulations of enzyme replacement, cost of medications, and patient compliance.”
Some Patients With Irritable Bowel Syndrome May Have Exocrine Pancreatic Insufficiency
Leeds, J. S., Hopper, A. D., Sidhu, R., Simmonette, A., Azadbakht, N., Hoggard, N., Morley, S., & Sanders, D. S. (2010) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2009.09.032 · Cited by 109 · cited 1×
“1%.(15) Furthermore, EPI prevalence of 4.”
Rothenbacher, D., Löw, M., Hardt, P. D., Klör, H.-U., Ziegler, H., & Brenner, H. (2005) · Scandinavian Journal of Gastroenterology · doi:10.1080/00365520510023116 · Cited by 100
Benini, L., Amodio, A., Campagnola, P., Agugiaro, F., Cristofori, C., Micciolo, R., Magro, A., Gabbrielli, A., Cabrini, G., Moser, L., et al. (2013) · Pancreatology · doi:10.1016/j.pan.2012.11.307 · Cited by 100 · cited 1×
“…risk High risk High risk Low risk Low risk Halloran 2011 Low risk Low risk High risk High risk High risk Low risk Low risk Wali 2012 High risk Low risk Low risk High risk High risk Low risk Low risk Benini 2013 Low risk Low risk High risk Unknown Low risk Low risk High risk Supplementary Table 7.”
Löser, C. (1998) · Scandinavian Journal of Gastroenterology · doi:10.1080/00365529850170946 · Cited by 95 · cited 1×
“…1997 High risk Low risk Low risk High risk Low risk Low risk Low risk Soldan 1997 High risk Low risk Low risk Low risk Low risk Low risk Low risk Loser 1998 High risk Low risk Low risk Unknown Low risk Low risk Low risk Lankisch 1998 Low risk Low risk Low risk Unknown Low risk Low risk Low…”
Walkowiak, J., Herzig, K., Strzykala, K., Przysławski, J., & Krawczyński, M. (2002) · PEDIATRICS · doi:10.1542/peds.110.1.e7 · Cited by 82 · cited 12×
“True Positive, False Positive, False Negative, and True Negative of Studies Included in the Meta-analysis of Fecal Elastase-1 Versus Secretin Stimulation Test Study (ref) Cases (n) Control subjects (n) TP (n) FP (n) FN (n) TN (n) Stein10 54 53 50 3 4 50 Loser9 44 85 41 6 3 79 Amann26 14 15 10 0 4 15 Katschinski27 11 2…”
InfluentialHahn, J.-U., Kerner, W., Maisonneuve, P., Lowenfels, A. B., & Lankisch, P. G. (2008) · Pancreas · doi:10.1097/mpa.0b013e3181656f8 · Cited by 70 · cited 7×
“Specifically, excluding the study by Hahn et al [30] that included type 1 diabetes and study by Wali et al [31] that included patients with failure to thrive did not change the results.”
InfluentialFine, K. D., & Ogunji, F. (2000) · American Journal of Clinical Pathology · doi:10.1309/0t2w-nn7f-7t8q-5n8c · Cited by 68 · cited 1×
“5 considered the gold standard among the indirect pancreatic function tests [11, 12].”
Katschinski, M., Schirra, J. R. J., Bross, A., Göke, B., & Arnold, R. (1997) · Pancreas · doi:10.1097/00006676-199708000-00012 · Cited by 58 · cited 3×
“When the studies with subjects ≥ 18 years of age were included [9] [26] [27] [28] [29] [23], [30] the pooled sensitivity and specificity estimates were 0.”
Diagnostic value of fasting plasma peptide concentrations in patients with chronic diarrhea
Schiller, L. R., Rivera, L. M., Santangelo, W. C., Little, K. H., & Fordtran, J. S. (1994) · Digestive Diseases and Sciences · doi:10.1007/bf02090374 · Cited by 39 · cited 1×
“Because EPI is a frequent cause of diarrhea of obscure origin [3] and can be effectively treated with enzyme supplementation, the ability to accurately diagnose EPI is critical.”
Faecal Elastase 1: A Marker of Exocrine Pancreatic Insufficiency in Cystic Fibrosis
Phillips, I., Rowe, D. J., Dewar, P., & Connett, G. J. (1999) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456329903600606 · Cited by 38 · cited 1×
“However, FE-1 tests are known to have assay variability, which could influence the accuracy of the test.(20,21) Despite the widespread use of FE-1 in screening for EPI, the diagnostic accuracy of FE-1 is not clear.”
Schneider, A. R. J., Funk, B., Caspary, W. F., & Stein, J. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2004.046888 · Cited by 34 · cited 1×
“The commercially available enzyme-linked immunosorbent assay kit uses 2 specific monoclonal antibodies against human elastase-1 to apply on a spot fecal sample.(18,19) Immunoassay for FE-1 is relatively inexpensive, requires <1 g of stool, and is covered by most commercial insurance carriers.”
Vujasinović, M., Tepeš, B., Volfand, J., & Rudolf, S. (2015) · Postgraduate Medical Journal · doi:10.1136/postgradmedj-2015-133262 · Cited by 22 · cited 1×
“4% (diagnosed by FE-1 <200 mg/g) was documented in 90 patients who had serologic and histologic evidence of celiac disease in Slovenia; interestingly, the pancreas appeared normal on magnetic resonance imaging in all patients diagnosed with EPI in this study.(16) EPI was diagnosed (based on FE-1 <200 mg/g) in 15% of a…”
Cited by
ACG Clinical Guideline: Chronic Pancreatitis
Gardner, T. B., Adler, D. G., Forsmark, C. E., Sauer, B. G., Taylor, J. R., & Whitcomb, D. C. (2020) · American Journal of Gastroenterology · doi:10.14309/ajg.0000000000000535 · Cited by 374
Chronic, Noninfectious Diarrhea: A Review
Singh, P., Lee, A., Sheth, N. M., & Chey, W. D. (2026) · JAMA · doi:10.1001/jama.2026.0872 · Cited by 13
Metadata
- Authors
- Vanga, R. R., Tansel, A., Sidiq, S., El-Serag, H. B., & Othman, M. O.
- Venue
- Clinical Gastroenterology and Hepatology
- Publisher
- Elsevier BV
- Published
- 2018-08
- Volume
- 16
- Issue
- 8
- Pages
- 1220-1228.e4
- ISSN
- 1542-3565 (ISSN-L)
- OpenAlex
- W2785648231
- Cited by
- 221
- References
- 26
- FWCI
- 4.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.