The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Background removal from spectra by designing and minimising a non-quadratic cost function
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new look at the statistical model identification
Akaike, H. (1974) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1974.1100705 · Cited by 51,879
Robust Regression and Outlier Detection
Piepel, G. F. (1989) · Technometrics · doi:10.1080/00401706.1989.10488524 · Cited by 6,144
Robust Regression and Outlier Detection
Rousseeuw, P. J., & Leroy, A. M. (1987) · Wiley Series in Probability and Statistics · doi:10.1002/0471725382 · Cited by 5,609
Automated Method for Subtraction of Fluorescence from Biological Raman Spectra
Lieber, C. A., & Mahadevan-Jansen, A. (2003) · Applied Spectroscopy · doi:10.1366/000370203322554518 · Cited by 1,049
Nonlinear image recovery with half-quadratic regularization
Geman, D., & Yang, C. (1995) · IEEE Transactions on Image Processing · doi:10.1109/83.392335 · Cited by 1,000 · cited 1×
“Because the minimisation of these cost functions is not straightforward, we use half-quadratic minimisation [16,17].”
Eilers, P. H. C. (2004) · Analytical Chemistry · doi:10.1021/ac034800e · Cited by 636
KOENKER, R., NG, P., & PORTNOY, S. (1994) · Biometrika · doi:10.1093/biomet/81.4.673 · Cited by 635
Computing LTS Regression for Large Data Sets
ROUSSEEUW, P. J., & VAN DRIESSEN, K. (2006) · Data Mining and Knowledge Discovery · doi:10.1007/s10618-005-0024-4 · Cited by 606
Direct orthogonal signal correction
Westerhuis, J. A., de Jong, S., & Smilde, A. K. (2001) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(01)00102-2 · Cited by 317
Convex half-quadratic criteria and interacting auxiliary variables for image restoration
Idier, J. (2001) · IEEE Transactions on Image Processing · doi:10.1109/83.931094 · Cited by 166
Self-citationCurve Fitting and Linearity: Data Processing in Raman Spectroscopy
Vickers, T. J., Wambles, R. E., & Mann, C. K. (2001) · Applied Spectroscopy · doi:10.1366/0003702011952127 · Cited by 70
Background estimation in experimental spectra
(2000) · doi:10.1103/physreve.61.1152 · Cited by 58
Cited by
Using Raman spectroscopy to characterize biological materials
Butler, H. J., Ashton, L., Bird, B., Cinque, G., Curtis, K., Dorney, J., Esmonde-White, K., Fullwood, N. J., Gardner, B., Martin-Hirsch, P. L., et al. (2016) · Nature Protocols · doi:10.1038/nprot.2016.036 · Cited by 1,309
Baseline correction using adaptive iteratively reweighted penalized least squares
Zhang, Z.-M., Chen, S., & Liang, Y.-Z. (2010) · The Analyst · doi:10.1039/b922045c · Cited by 1,124
Baseline correction using asymmetrically reweighted penalized least squares smoothing
Baek, S.-J., Park, A., Ahn, Y.-J., & Choo, J. (2015) · The Analyst · doi:10.1039/c4an01061b · Cited by 477
Spectral pre-processing for biomedical vibrational spectroscopy and microspectroscopic imaging
Lasch, P. (2012) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2012.03.011 · Cited by 353
Review of Fluorescence Suppression Techniques in Raman Spectroscopy
Wei, D., Chen, S., & Liu, Q. (2015) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2014.999936 · Cited by 334
Metadata
- Authors
- Mazet, V., Carteret, C., Brie, D., Idier, J., & Humbert, B.
- Venue
- Chemometrics and Intelligent Laboratory Systems
- Publisher
- Elsevier BV
- Published
- 2005-04
- Volume
- 76
- Issue
- 2
- Pages
- 121-133
- ISSN
- 0169-7439 (ISSN-L)
- OpenAlex
- W2054921258
- Cited by
- 316
- References
- 12
- FWCI
- 6.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.