The DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Review of Fluorescence Suppression Techniques in Raman Spectroscopy
Open accessAbstract
Raman spectroscopy is an important and powerful technique for analyzing the chemical composition of biological or nonbiological samples in many fields. A serious challenge frequently encountered in Raman measurements arises from the existence of the concurrent fluorescence background. The fluorescence intensity is normally several orders of magnitude larger than the Raman scattering signal, especially in biological samples. Such fluorescence background must be suppressed in order to obtain accurate Raman spectra. Several different techniques have been explored for this purpose. These techniques could be generally grouped into time-domain, frequency-domain, wavelength-domain, and computational methods in addition to various Raman enhancement techniques and other unconventional methods. This review briefly describes the fundamental principles of each group of methods, reports the most recent advances, and makes comparison across those major categories of techniques in terms of cost and performance in a hope to guide interested readers to select proper methods for specific applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Principles of Fluorescence Spectroscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-46312-4 · Cited by 19,339
Surface-enhanced Raman scattering
Campion, A., & Kambhampati, P. (1998) · Chemical Society Reviews · doi:10.1039/a827241z · Cited by 3,401
Characterization of electronic transitions in complex molecules
Kasha, M. (1950) · Discussions of the Faraday Society · doi:10.1039/df9500900014 · Cited by 2,903
Fluorescence Lifetime Measurements and Biological Imaging
Berezin, M. Y., & Achilefu, S. (2010) · Chemical Reviews · doi:10.1021/cr900343z · Cited by 2,403
Raman Spectroscopy for Chemical Analysis
McCreery, R. L. (2000) · Wiley eBooks · doi:10.1002/0471721646 · Cited by 1,440
Coherent Anti-Stokes Raman Scattering Microscopy: Chemical Imaging for Biology and Medicine
Evans, C. L., & Xie, X. S. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112754 · Cited by 1,150
Automated Method for Subtraction of Fluorescence from Biological Raman Spectra
Lieber, C. A., & Mahadevan-Jansen, A. (2003) · Applied Spectroscopy · doi:10.1366/000370203322554518 · Cited by 1,049
Prospects for in vivo Raman spectroscopy
Hanlon, E. B., Manoharan, R., Koo, T.-W., Shafer, K. E., Motz, J. T., Fitzmaurice, M., Kramer, J. R., Itzkan, I., Dasari, R. R., & Feld, M. S. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/201 · Cited by 894
Fluorescence lifetime imaging – techniques and applications
BECKER, W. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03618.x · Cited by 890
Cited by
The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing
Esmonde-White, K. A., Cuellar, M., & Lewis, I. R. (2022) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03727-4 · Cited by 152
“Approaches to reduce fluorescence can be achieved through hardware modification and, with the advent of computerized spectral collection, through software [13].”
MethodTime-gated Raman spectroscopy – a review
Kögler, M., & Heilala, B. (2020) · Measurement Science and Technology · doi:10.1088/1361-6501/abb044 · Cited by 107
Mishra, A., Aghaee, M., Tamer, I. M., & Budman, H. (2025) · Spectroscopy Journal · doi:10.3390/spectroscj3020012 · Cited by 19
Korinth, F., Schmälzlin, E., Stiebing, C., Urrutia, T., Micheva, G., Sandin, C., Müller, A., Maiwald, M., Sumpf, B., Krafft, C., et al. (2020) · Sensors · doi:10.3390/s20236723 · Cited by 13
Shang, L., Bao, X., Peng, H., Chen, F., Wang, Y., Liu, K., Liang, P., Wang, Y., Tang, X., Masia, F., et al. (2025) · Light: Science & Applications · doi:10.1038/s41377-025-02020-8 · Cited by 4
Metadata
- Authors
- Wei, D., Chen, S., & Liu, Q.
- Venue
- Applied Spectroscopy Reviews
- Publisher
- Informa UK Limited
- Published
- 2015-01-20
- Volume
- 50
- Issue
- 5
- Pages
- 387-406
- ISSN
- 0570-4928 (ISSN-L)
- 1520-569X
- OpenAlex
- W1987542277
- Cited by
- 334
- References
- 66
- FWCI
- 7.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Review of Fluorescence Suppression Techniques in Raman Spectroscopy. https://app.cochat.ai/papers/10.1080/05704928.2014.999936
- The paper
- Wei, D., Chen, S., & Liu, Q. (2015). Review of Fluorescence Suppression Techniques in Raman Spectroscopy. Applied Spectroscopy Reviews. https://doi.org/10.1080/05704928.2014.999936
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.