The DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
A state–of–the-art review on indoor air pollution and strategies for indoor air pollution control
Open accessAbstract
Indoor air pollution has traditionally received less attention than outdoors pollution despite indoors pollutant levels are typically twice higher, and people spend 80-90% of their life in increasing air-tight buildings. More than 5 million people die every year prematurely from illnesses attributable to poor indoor air quality, which also causes multi-millionaire losses due to reduced employee's productivity, material damages and increased health system expenses. Indoor air pollutants include particulate matter, biological pollutants and over 400 different chemical organic and inorganic compounds, whose concentrations are governed by several outdoor and indoor factors. Prevention of pollutant is not always technically feasible, so the implementation of cost-effective active abatement units is required. Up to date no single physical-chemical technology is capable of coping with all indoor air pollutants in a cost-effective manner. This problem requires the use of sequential technology configurations at the expenses of superior capital and operating costs. In addition, the performance of conventional physical-chemical technologies is still limited by the low concentrations, the diversity and the variability of pollutants in indoor environments. In this context, biotechnologies have emerged as a cost-effective and sustainable platform capable of coping with these limitations based on the biocatalytic action of plants, bacteria, fungi and microalgae. Indeed, biological-based purification systems can improve the energy efficiency of buildings, while providing additional aesthetic and psychological benefits. This review critically assessed the state-of-the-art of the indoor air pollution problem and prevention strategies, along with the recent advances in physical-chemical and biological technologies for indoor pollutants abatement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ambient air pollution: a global assessment of exposure and burden of disease
Health Organization, W. (2016) · Clean Air Journal · doi:10.17159/2410-972x/2016/v26n2a4 · Cited by 2,024
WHO Guidelines for Indoor Air Quality: Selected Pollutants
Who Regional Office for Europe (2011) · Cited by 1,300
Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104789 · Cited by 1,064
Occupant productivity and office indoor environment quality: A review of the literature
Al Horr, Y., Arif, M., Kaushik, A., Mazroei, A., Katafygiotou, M., & Elsarrag, E. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.06.001 · Cited by 843
Photocatalytic purification of volatile organic compounds in indoor air: A literature review
Mo, J., Zhang, Y., Xu, Q., Lamson, J. J., & Zhao, R. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2009.01.034 · Cited by 804
Towards sustainable, energy-efficient and healthy ventilation strategies in buildings: A review
Chenari, B., Dias Carrilho, J., & Gameiro da Silva, M. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.01.074 · Cited by 515
Outdoor-indoor air pollution in urban environment: challenges and opportunity
Leung, D. Y. C. (2015) · Frontiers in Environmental Science · doi:10.3389/fenvs.2014.00069 · Cited by 401
A review of indoor air treatment technologies
Luengas, A., Barona, A., Hort, C., Gallastegui, G., Platel, V., & Elias, A. (2015) · Reviews in Environmental Science and Bio/Technology · doi:10.1007/s11157-015-9363-9 · Cited by 360
Sick building syndrome: Figure 1
Burge, P. S. (2004) · Occupational and Environmental Medicine · doi:10.1136/oem.2003.008813 · Cited by 345
Biological treatment of indoor air for VOC removal: Potential and challenges
Guieysse, B., Hort, C., Platel, V., Munoz, R., Ondarts, M., & Revah, S. (2008) · Biotechnology Advances · doi:10.1016/j.biotechadv.2008.03.005 · Cited by 308
Kim, K.-J., & Ahn, H.-G. (2012) · Microporous and Mesoporous Materials · doi:10.1016/j.micromeso.2011.11.051 · Cited by 263
Indoor air quality requirements in green building certifications
Wei, W., Ramalho, O., & Mandin, C. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.03.035 · Cited by 242
Smart ventilation energy and indoor air quality performance in residential buildings: A review
Guyot, G., Sherman, M. H., & Walker, I. S. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2017.12.051 · Cited by 226
Geiss, O., Giannopoulos, G., Tirendi, S., Barrero-Moreno, J., Larsen, B. R., & Kotzias, D. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2011.04.037 · Cited by 224
Edwards, R. D., Jurvelin, J., Saarela, K., & Jantunen, M. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(01)00230-8 · Cited by 213
Review of mass transfer aspects for biological gas treatment
Kraakman, N. J. R., Rocha-Rios, J., & van Loosdrecht, M. C. M. (2011) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-011-3365-5 · Cited by 210
Self-citationA Comparative Analysis of Odour Treatment Technologies in Wastewater Treatment Plants
Estrada, J. M., Kraakman, N. J. R. B., Muñoz, R., & Lebrero, R. (2011) · Environmental Science & Technology · doi:10.1021/es103478j · Cited by 209
Self-citationAssessment of indoor air quality in office buildings across Europe – The OFFICAIR study
Mandin, C., Trantallidi, M., Cattaneo, A., Canha, N., Mihucz, V. G., Szigeti, T., Mabilia, R., Perreca, E., Spinazzè, A., Fossati, S., et al. (2017) · Science of The Total Environment · doi:10.1016/j.scitotenv.2016.10.238 · Cited by 205
Screening Indoor Plants for Volatile Organic Pollutant Removal Efficiency
Yang, D. S., Pennisi, S. V., Son, K.-C., & Kays, S. J. (2009) · HortScience · doi:10.21273/hortsci.44.5.1377 · Cited by 194
Oxygen transfer and evolution in microalgal culture in open raceways
Mendoza, J. L., Granados, M. R., de Godos, I., Acién, F. G., Molina, E., Heaven, S., & Banks, C. J. (2013) · Bioresource Technology · doi:10.1016/j.biortech.2013.03.127 · Cited by 179
Wang, N., Raza, A., Si, Y., Yu, J., Sun, G., & Ding, B. (2013) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2013.02.019 · Cited by 175
Heterogeneous photocatalytic removal of toluene from air on building materials enriched with TiO2
Demeestere, K., Dewulf, J., De Witte, B., Beeldens, A., & Van Langenhove, H. (2008) · Building and Environment · doi:10.1016/j.buildenv.2007.01.016 · Cited by 174
The Potted-Plant Microcosm Substantially Reduces Indoor Air VOC Pollution: I. Office Field-Study
Wood, R. A., Burchett, M. D., Alquezar, R., Orwell, R. L., Tarran, J., & Torpy, F. (2006) · Water, Air, and Soil Pollution · doi:10.1007/s11270-006-9124-z · Cited by 172
Muñoz, R., Daugulis, A. J., Hernández, M., & Quijano, G. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2012.08.009 · Cited by 168
Self-citationHousehold air pollution from various types of rural kitchens and its exposure assessment
Sidhu, M. K., Ravindra, K., Mor, S., & John, S. (2017) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2017.01.051 · Cited by 167
Indoor air quality and energy management through real-time sensing in commercial buildings
Kumar, P., Martani, C., Morawska, L., Norford, L., Choudhary, R., Bell, M., & Leach, M. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2015.11.037 · Cited by 165
Air Pollution Exposure in European Cities: The "Expolis" Study.
Jantunen, M. J., Hänninen, O., Katsouyanni, K., KNÖPPEL, H., Künzli, N., Lebret, E., Maroni, M., Saarela, K., Šrám, R. J., & Zmirou‐Navier, D. (1997) · Joint Research Centre (European Commission) · Cited by 162
Broderick, Á., Byrne, M., Armstrong, S., Sheahan, J., & Coggins, A. M. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.05.020 · Cited by 161
A review of green systems within the indoor environment
Moya, T. A., van den Dobbelsteen, A., Ottelé, M., & Bluyssen, P. M. (2019) · Indoor and Built Environment · doi:10.1177/1420326x18783042 · Cited by 160
Which ornamental plant species effectively remove benzene from indoor air?
Liu, Y., Mu, Y., Zhu, Y., Ding, H., & Arens, N. C. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.08.001 · Cited by 148
Zhu, Q., Tang, X., Feng, S., Zhong, Z., Yao, J., & Yao, Z. (2019) · Journal of Membrane Science · doi:10.1016/j.memsci.2019.03.075 · Cited by 143
Rapid Inactivation of Biological Species in the Air using Atmospheric Pressure Nonthermal Plasma
Liang, Y., Wu, Y. H., Sun, K., Chen, Q., Shen, F., Zhang, J., Yao, M., Zhu, T., & Fang, J. (2012) · Environmental Science & Technology · doi:10.1021/es203770q · Cited by 142
Hubbard, H. F., Coleman, B., Sarwar, G., & Corsi, R. L. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2005.00388.x · Cited by 122
Performance of air cleaners for removing multiple volatile organic compounds in indoor air
Chen, W., Zhang, J. S., & Zhang, Z. (2005) · ASHRAE winter conference papers · Cited by 122
Relationship between sources and patterns of VOCs in indoor air
Rösch, C., Kohajda, T., Röder, S. W., von Bergen�, M., & Schlink, U. (2013) · Atmospheric Pollution Research · doi:10.5094/apr.2014.016 · Cited by 120
Torpy, F., Clements, N., Pollinger, M., Dengel, A., Mulvihill, I., He, C., & Irga, P. (2018) · Air Quality, Atmosphere & Health · doi:10.1007/s11869-017-0518-4 · Cited by 120
Lebrero, R., Gondim, A. C., Pérez, R., García-Encina, P. A., & Muñoz, R. (2013) · Water Research · doi:10.1016/j.watres.2013.09.055 · Cited by 119
Self-citationYip, F. Y., Christensen, B. E., Sircar, K. D., Naeher, L. P., Bruce, N., Pennise, D. M., Lozier, M., Pilishvili, T., Farrar, J. L., Stanistreet, D., et al. (2016) · Environment International · doi:10.1016/j.envint.2016.11.015 · Cited by 112
Profiling indoor plants for the amelioration of high CO2 concentrations
Torpy, F. R., Irga, P. J., & Burchett, M. D. (2014) · Urban forestry & urban greening · doi:10.1016/j.ufug.2013.12.004 · Cited by 109
Singh, D., Kumar, A., Kumar, K., Bupender, S., Mina, U., Singh, B. B., & Jain, V. K. (2016) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2016.08.086 · Cited by 107
Indoor air quality of everyday use spaces dedicated to specific purposes—a review
Marć, M., Śmiełowska, M., Namieśnik, J., & Zabiegała, B. (2017) · Environmental Science and Pollution Research · doi:10.1007/s11356-017-0839-8 · Cited by 106
Wang, Z., Pei, J., & Zhang, J. S. (2014) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2014.07.059 · Cited by 101
Volatile Organic Compounds (VOCs) in Conventional and High Performance School Buildings in the U.S.
Zhong, L., Su, F., & Batterman, S. (2017) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph14010100 · Cited by 95
Photocatalytic oxidation of VOCs at ppb level using a closed-loop reactor: The mixture effect
Hequet, V., Raillard, C., Debono, O., Thévenet, F., Locoge, N., & Coq, L. L. (2017) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2017.12.041 · Cited by 94
Xu, Z., Yu, J., & Xiao, W. (2013) · Chemistry - A European Journal · doi:10.1002/chem.201300438 · Cited by 93
Performance of a biological degradation method for indoor formaldehyde removal
Lu, N., Pei, J., Zhao, Y., Qi, R., & Liu, J. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.05.007 · Cited by 92
Measurement of volatile organic compounds (VOCs) in libraries and archives in Florence (Italy)
Cincinelli, A., Martellini, T., Amore, A., Dei, L., Marrazza, G., Carretti, E., Belosi, F., Ravegnani, F., & Leva, P. (2016) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2016.07.201 · Cited by 92
Dodson, R. E., Levy, J. I., Spengler, J. D., Shine, J. P., & Bennett, D. H. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.10.088 · Cited by 91
PM 2.5 in household kitchens of Bhaktapur, Nepal, using four different cooking fuels
Pokhrel, A. K., Bates, M., Acharya, J., Valentiner‐Branth, P., Chandyo, R. K., Shrestha, P. S., Raut, A. K., & Smith, K. R. (2015) · Atmospheric Environment · doi:10.1016/j.atmosenv.2015.04.060 · Cited by 90
Kotzias, D., Geiss, O., Tirendi, S., Barrero-Moreno, J., Reina, V., Gotti, A., Cimino-Reale, G., Casati, B., MARAFANTE, E., & Sarigiannis, D. A. (2009) · Fresenius environmental bulletin · Cited by 80
Indoor Air Contaminants and Their Impact on Respiratory Pathologies
Fernández, L. C., Álvarez, R. F., González‐Barcala, F. J., & Portal, J. A. R. (2012) · Archivos de Bronconeumología · doi:10.1016/j.arbr.2012.11.004 · Cited by 79
Pilot study of high-performance air filtration for classroom applications
Polidori, A., Fine, P. M., White, V., & Kwon, P. S. (2012) · Indoor Air · doi:10.1111/ina.12013 · Cited by 75
Indoor particle size distributions in homes with open fires and improved Patsari cook stoves☆
Armendáriz-Arnez, C., Edwards, R. D., Johnson, M. A., Rosas, I., Espinosa, F., & Masera, O. (2010) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.04.049 · Cited by 74
Indoor air quality of non-residential urban buildings in Delhi, India
Datta, A., Suresh, R., Gupta, A., Singh, D., & Kulshrestha, P. (2017) · International Journal of Sustainable Built Environment · doi:10.1016/j.ijsbe.2017.07.005 · Cited by 74
Jo, W., & Yang, C.-H. (2009) · Separation and Purification Technology · doi:10.1016/j.seppur.2009.02.014 · Cited by 70
Long-term performance of passive materials for removal of ozone from indoor air
Cros, C. J., Morrison, G., Siegel, J. A., & Corsi, R. L. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2011.00734.x · Cited by 69
ALD-seeded hydrothermally-grown Ag/ZnO nanorod PTFE membrane as efficient indoor air filter
Feng, S., Li, D., Low, Z.-X. N., Liu, Z., Zhong, Z., Hu, Y., Wang, Y., & Xing, W. (2017) · Journal of Membrane Science · doi:10.1016/j.memsci.2017.02.042 · Cited by 68
Contaminación del aire interior y su impacto en la patología respiratoria
Fernández, L. C., Álvarez, R. F., González‐Barcala, F. J., & Portal, J. A. R. (2012) · Archivos de Bronconeumología · doi:10.1016/j.arbres.2012.04.005 · Cited by 58
Air exchange rates and migration of VOCs in basements and residences
Du, L., Batterman, S., Godwin, C., Rowe, Z. E., & Chin, J.-Y. (2014) · Indoor Air · doi:10.1111/ina.12178 · Cited by 54
Anbalagan, A., Cervantes, A. L. T., Posadas, E., Rojo, E. M., Lebrero, R., Sánchez, A. G., Nehrenheim, E., & Muñoz, R. (2017) · Journal of CO2 Utilization · doi:10.1016/j.jcou.2017.07.016 · Cited by 51
Self-citationSymbiosis optimization of building envelopes and micro-algae photobioreactors
Araji, M. T., & Shahid, I. (2018) · Journal of Building Engineering · doi:10.1016/j.jobe.2018.02.008 · Cited by 48
Zeng, Y., Xie, R., Cao, J., Chen, Z., Fan, Q., Liu, B., Lian, X., & Huang, H. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.124219 · Cited by 47
López, L. R., Deaton, K. E., & Deshusses, M. A. (2018) · Environmental Science & Technology · doi:10.1021/acs.est.8b05209 · Cited by 42
Exploring the Feasibility of Algae Building Technology in NSW
Wilkinson, S. J., Stoller, P., Ralph, P. J., Hamdorf, B., Catana, L. N., & Kuzava, G. D. S. (2017) · Procedia Engineering · doi:10.1016/j.proeng.2017.04.272 · Cited by 39
Yamamoto, S. S., Louis, V. R., Sié, A., & Sauerborn, R. (2013) · Environmental Science and Pollution Research · doi:10.1007/s11356-013-2062-6 · Cited by 38
Improving Indoor Air Quality through the Use of Ultraviolet Technology in Commercial Buildings
de Robles, D., & Kramer, S. W. (2017) · Procedia Engineering · doi:10.1016/j.proeng.2017.08.021 · Cited by 36
Sung, J.-H., Kim, M., Kim, Y., Han, B., Hong, K., & Kim, H. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106422 · Cited by 35
Oh, G. S., Jung, G. J., Seo, M. H., et al. (2011) · Horticulture Environment and Biotechnology · doi:10.1007/s13580-011-0169-6 · Cited by 28
Indoor Air Quality and Thermal Conditions in a Primary School with a Green Roof System
Barmparesos, N., Assimakopoulos, M.-N., Assimakopoulos, V. D., Loumos, N., Sotiriou, M. A., & Koukoumtzis, A. (2018) · Atmosphere · doi:10.3390/atmos9020075 · Cited by 28
Performance of sorption- and photocatalytic oxidation-based indoor passive panel technologies
Zuraimi, M. S., Magee, R. J., Won, D., Nong, G., Arsenault, C. D., Yang, W., So, S., Nilsson, G., Abebe, L., & Alliston, C. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.03.004 · Cited by 22
A hybrid biological process of indoor air treatment for toluene removal
Hort, C., Platel, V., Sochard, S., Munoz, A. T. L., Ondarts, M., Reguer, A., Barona, A., & Ηλίας, Α. (2014) · Journal of the Air & Waste Management Association · doi:10.1080/10962247.2014.958622 · Cited by 15
Srivastava, I., Singh, P. K., Gupta, T., & Sankararamakrishnan, N. (2019) · Journal of environmental chemical engineering · doi:10.1016/j.jece.2019.103271 · Cited by 10
Design and development of nanostructured filter media for VOCs abatement in closed environments
Roso, M., Falcomer, D., Azzano, A., Boaretti, C., Donadini, R., Lorenzetti, A., & Modesti, M. (2019) · Journal of Environmental Chemical Engineering · doi:10.1016/j.jece.2019.103045 · Cited by 5
Niederwieser, T. (2015) · CU Scholar (University of Colorado Boulder) · Cited by 2
Cited by
Selectivity in Chemiresistive Gas Sensors: Strategies and Challenges
Bulemo, P. M., Kim, D.-H., Shin, H., Cho, H.-J., Koo, W.-T., Choi, S.-J., Park, C., Ahn, J., Güntner, A. T., Penner, R. M., et al. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00592 · Cited by 418
Sadrizadeh, S., Yao, R., Yuan, F., Awbi, H., Bahnfleth, W., Bi, Y., Cao, G., Croitoru, C., de Dear, R., Haghighat, F., et al. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.104908 · Cited by 375
Asghar, N., Hussain, A., Nguyen, D. A., Ali, S., Hussain, I., Junejo, A., & Ali, A. (2024) · Journal of Nanobiotechnology · doi:10.1186/s12951-023-02151-3 · Cited by 258
Chen, Y., Liang, Z., Li, G., & An, T. (2024) · Environment International · doi:10.1016/j.envint.2024.108857 · Cited by 49
Metadata
- Authors
- González-Martín, J., Kraakman, N. J. R., Pérez, C., Lebrero, R., & Muñoz, R.
- Venue
- Chemosphere
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 262
- Pages
- 128376
- ISSN
- 0045-6535 (ISSN-L)
- OpenAlex
- W3087039125
- Cited by
- 562
- References
- 74
- FWCI
- 19.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.