Is CO2 an Indoor Pollutant? Direct Effects of Low-to-Moderate CO2 Concentrations on Human Decision-Making Performance
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Background: Associations of higher indoor carbon dioxide (CO2) concentrations with impaired work performance, increased health symptoms, and poorer perceived air quality have been attributed to correlation of indoor CO2 with concentrations of other indoor air pollutants that are also influenced by rates of outdoor-air ventilation. Objectives: We assessed direct effects of increased CO2, within the range of indoor concentrations, on decision making. Methods: Twenty-two participants were exposed to CO2 at 600, 1,000, and 2,500 ppm in an office-like chamber, in six groups. Each group was exposed to these conditions in three 2.5-hr sessions, all on 1 day, with exposure order balanced across groups. At 600 ppm, CO2 came from outdoor air and participants’ respiration. Higher concentrations were achieved by injecting ultrapure CO2. Ventilation rate and temperature were constant. Under each condition, participants completed a computer-based test of decision-making performance as well as questionnaires on health symptoms and perceived air quality. Participants and the person administering the decision-making test were blinded to CO2 level. Data were analyzed with analysis of variance models. Results: Relative to 600 ppm, at 1,000 ppm CO2, moderate and statistically significant decrements occurred in six of nine scales of decision-making performance. At 2,500 ppm, large and statistically significant reductions occurred in seven scales of decision-making performance (raw score ratios, 0.06–0.56), but performance on the focused activity scale increased. Conclusions: Direct adverse effects of CO2 on human performance may be economically important and may limit energy-saving reductions in outdoor air ventilation per person in buildings. Confirmation of these findings is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Low ventilation rates and CO2 concentrations normally found in office buildings (approximately 1,000 ppm) have been recently associated with impairment in multiple domains of high-order cognitive function [45,46].”
From Reduced cognitive function during a heat wave among residents of non-air-conditioned buildings: An observational study of young adults in the summer of 2016 (2018) · cites this paper as [45]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
Self-citationWARGOCKI, P., WYON, D. P., SUNDELL, J., CLAUSEN, G., & FANGER, P. O. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004222.x · Cited by 688
Associations between classroom CO2 concentrations and student attendance in Washington and Idaho
Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., & Faulkner, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00251.x · Cited by 462
Self-citationCarbon Dioxide and the Cerebral Circulation
Brian, J. E. (1998) · Anesthesiology · doi:10.1097/00000542-199805000-00029 · Cited by 395
MILTON, D. K., GLENCROSS, P. M., & WALTERS, M. D. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004212.x · Cited by 364
Behavior in the complex environment.
Streufert, S., & Streufert, S. C. (1978) · Cited by 302
Self-citationPhysiological Impact of the N95 Filtering Facepiece Respirator on Healthcare Workers
Roberge, R. J., Coca, A., Williams, W. J., Powell, J. B., & Palmiero, A. J. (2010) · Respiratory Care · doi:10.4187/respcare.10550569 · Cited by 276
Woods, S. W. (1988) · Archives of General Psychiatry · doi:10.1001/archpsyc.1988.01800250051007 · Cited by 265 · cited 2×
“Inhaled CO2 at concentrations of tens of thousands of ppm has been associated with changes in respiration, cerebral blood flow, cardiac output, and anxiety (Brian Jr 1998; Kaye et al. 2004; Lipsett et al. 1994; Roberge et al. 2010; Woods et al. 1988).”
BackgroundErdmann, C. A., & Apte, M. G. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00298.x · Cited by 147 · cited 1×
“…perceptions of poor air quality, increased prevalence of acute health symptoms (e.g., headache, mucosal irritation), slower work performance, and increased absence (Erdmann and Apte 2004; Federspiel et al. 2004; Milton et al. 2000; Seppanen et al. 1999; Shendell et al. 2004; Wargocki et al. 2000).”
BackgroundKaye, J., Buchanan, F., Kendrick, A. H., Johnson, P. L., Lowry, C. A., Bailey, J., Nutt, D., & Lightman, S. L. (2004) · Journal of Neuroendocrinology · doi:10.1111/j.0953-8194.2004.01158.x · Cited by 134 · cited 2×
“CO2 is the key regulator of respiration and arousal of behavioral states in humans (Kaye et al. 2004).”
Background
Research works printed but not linked: 7
- ACGIH (American Conference of Governmental Industrial Hygienists), 2011, TLVs and BEIs
- Corsi, 2002, Carbon dioxide levels and dynamics in elementary schools: results of the TESIAS Study. In: Indoor Air 2002, 9th International Conference on Indoor Air Quality and Climate (Levin H, ed)
- Knibbs, 2008, On-road quantification of the key characteristics of automobile HVAC systems in relation to in-cabin submicrometer particle pollution [Abstract]. In: 11th International Conference on Indoor Air Quality and Climate: Indoor Air 2008. Copenhagen, Denmark.
- Mudarri, 1997, Potential correction factors for interpreting CO2 measurements in buildings., ASHRAE Transactions, 103, 244
- Persily, 1997, Evaluating building IAQ and ventilation with carbon dioxide., ASHRAE Transactions, 103, 193
- Satish, 2009, Novel assessment of psychiatry residents: SMS simulations. Accreditation Council for Graduate Medical Education (ACGME) Bulletin, 18–23 January.
- Swezey, 1998, Preliminary development of a computer-based team performance assessment simulation., Int J Cogn Ergonomics, 2, 163
Cited by
Allen, J. G., MacNaughton, P., Satish, U., Santanam, S., Vallarino, J., & Spengler, J. D. (2016) · Environmental Health Perspectives · doi:10.1289/ehp.1510037 · Cited by 977
“However, this conventional thinking is being challenged as the evidence mounts for CO2 as a direct pollutant, not just a marker for other pollutants (Satish et al. 2012).”
BackgroundMethodInfluentialSelf-citationDirect human health risks of increased atmospheric carbon dioxide
Jacobson, T. A., Kler, J. S., Hernke, M. T., Braun, R. K., Meyer, K. C., & Funk, W. E. (2019) · Nature Sustainability · doi:10.1038/s41893-019-0323-1 · Cited by 609
Carbon dioxide generation rates for building occupants
Persily, A., & de Jonge, L. (2017) · Indoor Air · doi:10.1111/ina.12383 · Cited by 566
A state–of–the-art review on indoor air pollution and strategies for indoor air pollution control
González-Martín, J., Kraakman, N. J. R., Pérez, C., Lebrero, R., & Muñoz, R. (2021) · Chemosphere · doi:10.1016/j.chemosphere.2020.128376 · Cited by 562
Azuma, K., Kagi, N., Yanagi, U., & Osawa, H. (2018) · Environment International · doi:10.1016/j.envint.2018.08.059 · Cited by 403
Metadata
- Authors
- Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J.
- Affiliations
- SUNY Upstate Medical University (US)
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Mendell, Mark J.
- Venue
- Environmental Health Perspectives
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-09-20
- Volume
- 120
- Issue
- 12
- Pages
- 1671-1677
- ISSN
- 0091-6765 (ISSN-L)
- 1552-9924
- PMC
- PMC3548274
- OpenAlex
- W2089734242
- Cited by
- 1,064
- References
- 24
- Citations by year
- 2026: 105 · 2025: 119 · 2024: 103 · 2023: 108 · 2022: 92 · 2021: 123 · 2020: 94 · 2019: 80 · 2018: 63 · 2017: 47 · 2016: 44 · 2015: 34 · 2014: 33 · 2013: 16 · 2012: 1
- FWCI
- 18.60
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- public-domain
- creativecommons.org/licenses/by/4.0/ (vor, 1926 d)
- Locations
- Environmental Health Perspectives (publishedVersion, public-domain)
- Europe PMC (PubMed Central) (publishedVersion, public-domain)
- PubMed Central (publishedVersion, public-domain)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- U.S. Environmental Protection Agency
- Syracuse University
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- indoor carbon dioxide, decision performance, cognitive performance, indoor air quality, ventilation rate, health symptoms, perceived air quality, CO2 exposure, office buildings
- MeSH terms
- Adolescent, Adult, Air Pollutants, Analysis of Variance, Carbon Dioxide, Decision Making, Dose-Response Relationship, Drug, Environmental Exposure, Environmental Monitoring, Female, Humans, Male, Surveys and Questionnaires, Ventilation, Air Pollution, Indoor, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Is CO2 an Indoor Pollutant? Direct Effects of Low-to-Moderate CO2 Concentrations on Human Decision-Making Performance. https://app.cochat.ai/papers/10.1289/ehp.1104789
- The paper
- Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J. (2012). Is CO2 an Indoor Pollutant? Direct Effects of Low-to-Moderate CO2 Concentrations on Human Decision-Making Performance. Environmental Health Perspectives. https://doi.org/10.1289/ehp.1104789
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.

