CoChat

Monitoring microplastics in drinking water: An interlaboratory study to inform effective methods for quantifying and characterizing microplastics

De Frond, Hannah, Thornton Hampton, Leah, Kotar, Syd, Gesulga, Kristine, Matuch, Cindy, Lao, Wenjian, Weisberg, Stephen B., Wong, Charles S., Rochman, Chelsea M. · 2022 · Chemosphere
Cited by 130

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

California Senate Bill 1422 requires the development of State-approved standardized methods for quantifying and characterizing microplastics in drinking water. Accordingly, we led an interlaboratory microplastic method evaluation study, with 22 participating laboratories from six countries, to evaluate the performance of widely used methods: sample extraction via filtering/sieving, optical microscopy, FTIR spectroscopy, and Raman spectroscopy. Three spiked samples of simulated clean water and a laboratory blank were sent to each laboratory with a prescribed standard operating procedure for particle extraction, quantification, and characterization. The samples contained known amounts of microparticles within four size fractions (1-20 μm, 20-212 μm, 212-500 μm, >500 μm), four polymer types (PE, PS, PVC, and PET), and six colors (clear, white, green, blue, red, and orange). They also included false positives (natural hair, fibers, and shells) that may be mistaken for microplastics. Among laboratories, mean particle recovery using stereomicroscopy was 76% ± 10% (SE). For particles in the three largest size fractions, mean recovery was 92% ± 12% SD. On average, laboratory contamination from blank samples was 91 particles (±141 SD). FTIR and Raman spectroscopy accurately identified microplastics by polymer type for 95% and 91% of particles analyzed, respectively. Per particle, FTIR spectroscopy required the longest time for analysis (12 min ± 9 SD). Participants demonstrated excellent recovery and chemical identification for particles greater than 50 μm in size, with opportunity for increased accuracy and precision through training and further method refinement. This work has informed methods and QA/QC for microplastics monitoring in drinking water in the State of California.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.chemosphere.2022.134282

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 130

Metadata

Authors
De Frond, H., Thornton Hampton, L., Kotar, S., Gesulga, K., Matuch, C., Lao, W., Weisberg, S. B., Wong, C. S., & Rochman, C. M.
Venue
Chemosphere
Publisher
Elsevier BV
Published
2022-07
Volume
298
Pages
134282
ISSN
0045-6535 (ISSN-L)
OpenAlex
W4220883008
Cited by
130
References
8
FWCI
5.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Monitoring microplastics in drinking water: An interlaboratory study to inform effective methods for quantifying and characterizing microplastics. https://app.cochat.ai/papers/10.1016/j.chemosphere.2022.134282
The paper
De Frond, H., Thornton Hampton, L., Kotar, S., Gesulga, K., Matuch, C., Lao, W., Weisberg, S. B., Wong, C. S., & Rochman, C. M. (2022). Monitoring microplastics in drinking water: An interlaboratory study to inform effective methods for quantifying and characterizing microplastics. Chemosphere. https://doi.org/10.1016/j.chemosphere.2022.134282

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.