The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Application of central composite design to the optimisation of aqueous two-phase extraction of human antibodies
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of protein using bicinchoninic acid
Smith, P. K., Krohn, R. I., Hermanson, G. T., Mallia, A. K., Gartner, F. H., Provenzano, M. D., Fujimoto, E. K., Goeke, N. M., Olson, B. J., & Klenk, D. C. (1985) · Analytical Biochemistry · doi:10.1016/0003-2697(85)90442-7 · Cited by 18,482
Cited by
Response surface methodology (RSM) as a tool for optimization in analytical chemistry
Bezerra, M. A., Santelli, R. E., Oliveira, E. P., Villar, L. S., & Escaleira, L. A. (2008) · Talanta · doi:10.1016/j.talanta.2008.05.019 · Cited by 6,075
Farajzadeh, M. A., Vardast, M. R., & Bahram, M. (2009) · Chromatographia · doi:10.1365/s10337-008-0912-z · Cited by 36
Ovomucoid partitioning in aqueous two-phase systems
de Oliveira, F. C., dos Reis Coimbra, J. S., da Silva, L. H. M., Rojas, E. E. G., & do Carmo Hespanhol da Silva, M. (2009) · Biochemical Engineering Journal · doi:10.1016/j.bej.2009.07.002 · Cited by 35
Metadata
- Authors
- Rosa, P. A. J., Azevedo, A. M., & Aires-Barros, M. R.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2007-02
- Volume
- 1141
- Issue
- 1
- Pages
- 50-60
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W2002374506
- Cited by
- 229
- References
- 1
- FWCI
- 13.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of central composite design to the optimisation of aqueous two-phase extraction of human antibodies. https://app.cochat.ai/papers/10.1016/j.chroma.2006.11.075
- The paper
- Rosa, P. A. J., Azevedo, A. M., & Aires-Barros, M. R. (2007). Application of central composite design to the optimisation of aqueous two-phase extraction of human antibodies. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2006.11.075
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.