The DOI matches its Crossref record; 110 of the 110 references it cites were found in a registry or an index.
Sample preparation techniques for the determination of trace residues and contaminants in foods
Open accessAbstract
The determination of trace residues and contaminants in complex matrices, such as food, often requires extensive sample extraction and preparation prior to instrumental analysis. Sample preparation is often the bottleneck in analysis and there is a need to minimise the number of steps to reduce both time and sources of error. There is also a move towards more environmentally friendly techniques, which use less solvent and smaller sample sizes. Smaller sample size becomes important when dealing with real life problems, such as consumer complaints and alleged chemical contamination. Optimal sample preparation can reduce analysis time, sources of error, enhance sensitivity and enable unequivocal identification, confirmation and quantification. This review considers all aspects of sample preparation, covering general extraction techniques, such as Soxhlet and pressurised liquid extraction, microextraction techniques such as liquid phase microextraction (LPME) and more selective techniques, such as solid phase extraction (SPE), solid phase microextraction (SPME) and stir bar sorptive extraction (SBSE). The applicability of each technique in food analysis, particularly for the determination of trace organic contaminants in foods is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anastassiades, M., Lehotay, S. J., Štajnbaher, D., & Schenck, F. J. (2003) · Journal of AOAC INTERNATIONAL · doi:10.1093/jaoac/86.2.412 · Cited by 5,670
Solid phase microextraction with thermal desorption using fused silica optical fibers
Arthur, C. L., & Pawliszyn, J. (1990) · Analytical Chemistry · doi:10.1021/ac00218a019 · Cited by 4,997
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Solid phase microextraction : theory and practice
Pawliszyn, J. B. (1997) · Medical Entomology and Zoology · Cited by 2,277
Baltussen, E., Sandra, P., David, F., & Cramers, C. (1999) · Journal of Microcolumn Separations · doi:10.1002/(sici)1520-667x(1999)11:10<737::aid-mcs7>3.0.co;2-4 · Cited by 1,502
Applications of solid-phase microextraction in food analysis
Kataoka, H., Lord, H. L., & Pawliszyn, J. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00309-5 · Cited by 1,119
Solid-phase extraction: method development, sorbents, and coupling with liquid chromatography
Hennion, M.-C. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00832-8 · Cited by 1,044
Analytical Chemistry in a Drop. Solvent Extraction in a Microdrop
Liu, H., & Dasgupta, P. K. (1996) · Analytical Chemistry · doi:10.1021/ac960145h · Cited by 751
Soxhlet extraction of solid materials: an outdated technique with a promising innovative future
Luque de Castro, M. D., & Garcı́a-Ayuso, L. E. (1998) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00233-5 · Cited by 727
Developments in liquid-phase microextraction
Psillakis, E., & Kalogerakis, N. (2003) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(03)01007-0 · Cited by 608
Cited by
Tutorial: design and fabrication of nanoparticle-based lateral-flow immunoassays
Parolo, C., Sena-Torralba, A., Bergua, J. F., Calucho, E., Fuentes-Chust, C., Hu, L., Rivas, L., Álvarez-Diduk, R., Nguyen, E. P., Cinti, S., et al. (2020) · Nature Protocols · doi:10.1038/s41596-020-0357-x · Cited by 576
Miniaturized solid-phase extraction techniques
Płotka-Wasylka, J., Szczepańska, N., de la Guardia, M., & Namieśnik, J. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.04.026 · Cited by 517
Antibiotic Residues in Food: Extraction, Analysis, and Human Health Concerns
Chen, J., Ying, G.-G., & Deng, W.-J. (2019) · Journal of Agricultural and Food Chemistry · doi:10.1021/acs.jafc.9b01334 · Cited by 514
Whitcombe, M. J., Kirsch, N., & Nicholls, I. A. (2014) · Journal of Molecular Recognition · doi:10.1002/jmr.2347 · Cited by 445
Nondestructive Sampling of Living Systems Using in Vivo Solid-Phase Microextraction
Ouyang, G., Vuckovic, D., & Pawliszyn, J. (2011) · Chemical Reviews · doi:10.1021/cr100203t · Cited by 426
Analytical methods for the determination of bisphenol A in food
Ballesteros-Gómez, A., Rubio, S., & Pérez-Bendito, D. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.06.037 · Cited by 407
Recent developments in solid-phase microextraction
Risticevic, S., Niri, V. H., Vuckovic, D., & Pawliszyn, J. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2375-3 · Cited by 376
Granados-Chinchilla, F., & Rodríguez, C. (2017) · Journal of Analytical Methods in Chemistry · doi:10.1155/2017/1315497 · Cited by 372
Protocol for solid-phase microextraction method development
Risticevic, S., Lord, H., Górecki, T., Arthur, C. L., & Pawliszyn, J. (2010) · Nature Protocols · doi:10.1038/nprot.2009.179 · Cited by 331
Development of dispersive micro-solid phase extraction based on micro and nano sorbents
Khezeli, T., & Daneshfar, A. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.01.004 · Cited by 327
Dadfarnia, S., & Haji Shabani, A. M. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.11.022 · Cited by 305
Critical overview of selected contemporary sample preparation techniques
Ramos, L. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.11.011 · Cited by 280
Recent developments in matrix solid-phase dispersion extraction
Capriotti, A. L., Cavaliere, C., Giansanti, P., Gubbiotti, R., Samperi, R., & Laganà, A. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.030 · Cited by 262
Zhang, Y., Liu, R., Hu, Y., & Li, G. (2009) · Analytical Chemistry · doi:10.1021/ac8018262 · Cited by 256
Potential of supramolecular solvents for the extraction of contaminants in liquid foods
Ballesteros-Gómez, A., Rubio, S., & Pérez-Bendito, D. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.06.029 · Cited by 177
Tsai, W.-H., Chuang, H.-Y., Chen, H.-H., Huang, J.-J., Chen, H.-C., Cheng, S.-H., & Huang, T.-C. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.10.008 · Cited by 98
Ratola, N., Alves, A., Kalogerakis, N., & Psillakis, E. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.04.054 · Cited by 49
Metadata
- Authors
- Ridgway, K., Lalljie, S. P. D., & Smith, R. M.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2007-06
- Volume
- 1153
- Issue
- 1-2
- Pages
- 36-53
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W1990211980
- Cited by
- 354
- References
- 110
- FWCI
- 25.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.