Automation of solid-phase microextraction on a 96-well plate format
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Studies have been performed assessing the feasibility and characterizing the automation of solid-phase microextraction (SPME) on a multi-well plate format. Four polycyclic aromatic hydrocarbons (PAHs), naphthalene, fluorene, anthracene and fluoranthene, were chosen as test analytes to demonstrate the technique due to their favorable partition coefficients, K(fw), between polydimethylsiloxane (PDMS) extraction phases and water. Four different PDMS configurations were investigated regarding their suitability. These included (i) a PDMS membrane; (ii) a multi-fiber device containing lengths of PDMS-coated flexible wire; (iii) a stainless steel pin covered with silicone hollow fiber membrane and (iv) commercial PDMS-coated flexible metal fiber assemblies. Of these configurations, the stainless steel pin covered with silicone tubing was chosen as a robust alternative. An array of 96 SPME devices that can be placed simultaneously into a 96-well plate was constructed to demonstrate the high-throughput potential when performing multiple microextractions in parallel. Different agitation methods were assessed including magnetic stirring, sonication, and orbital shaking at different speeds. Orbital shaking whilst holding the SPME device in a stationary position provided the optimum agitation conditions for liquid SPME. Once the analytes had been extracted, desorption of the analytes into an appropriate solvent was investigated. Liquid-phase SPME and solvent desorption on the multi-well plate format is shown to be a viable alternative for automated high-throughput SPME analysis compatible with both gas- and liquid-chromatography platforms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Solid Phase Microextraction Coupled to High-Performance Liquid Chromatography
Chen, J., & Pawliszyn, J. B. (1995) · Analytical Chemistry · doi:10.1021/ac00111a006 · Cited by 310
Self-citation
Cited by
Molecular imprinting: perspectives and applications
Chen, L., Wang, X., Lu, W., Wu, X., & Li, J. (2016) · Chemical Society Reviews · doi:10.1039/c6cs00061d · Cited by 2,460
Manousi, N., Wojnowski, W., Płotka-Wasylka, J., & Samanidou, V. (2023) · Green Chemistry · doi:10.1039/d3gc02347h · Cited by 1,685
The ten principles of green sample preparation
López-Lorente, Á. I., Pena-Pereira, F., Pedersen-Bjergaard, S., Zuin, V. G., Ozkan, S. A., & Psillakis, E. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116530 · Cited by 721
Nondestructive Sampling of Living Systems Using in Vivo Solid-Phase Microextraction
Ouyang, G., Vuckovic, D., & Pawliszyn, J. (2011) · Chemical Reviews · doi:10.1021/cr100203t · Cited by 426
Self-citationRecent developments in solid-phase microextraction
Risticevic, S., Niri, V. H., Vuckovic, D., & Pawliszyn, J. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2375-3 · Cited by 376
Self-citation
Metadata
- Authors
- Hutchinson, J. P., Setkova, L., & Pawliszyn, J.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2007-05
- Volume
- 1149
- Issue
- 2
- Pages
- 127-137
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W2040221728
- Cited by
- 90
- References
- 2
- FWCI
- 5.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).