The challenges of the analysis of basic compounds by high performance liquid chromatography: Some possible approaches for improved separations
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
This review considers some of the difficulties encountered with the analysis of ionised bases using reversed-phase chromatography, such as detrimental interaction with column silanol groups, and overloading which both lead to poor peak shapes. Methods of overcoming these problems in reversed-phase (RP) separations, by judicious selection of the column and mobile phase conditions, are discussed. Hydrophilic interaction chromatography is considered as an alternative method for the separation of some basic compounds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Alpert, A. J. (1990) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)96972-3 · Cited by 1,966
Practical HPLC Method Development
Snyder, L. R., Kirkland, J. J., & Glajch, J. L. (1997) · Wiley eBooks · doi:10.1002/9781118592014 · Cited by 1,746
A new form of chromatogram employing two liquid phases
Martin, A. J. P., & Synge, R. L. M. (1941) · Biochemical Journal · doi:10.1042/bj0351358 · Cited by 1,631
Practical HPLC Method Development
(1993) · Analytical Chemistry · doi:10.1021/ac00066a728 · Cited by 1,411
Hydrophilic interaction chromatography
Hemström, P., & Irgum, K. (2006) · Journal of Separation Science · doi:10.1002/jssc.200600199 · Cited by 1,176
The silanol group and its role in liquid chromatography
Nawrocki, J. (1997) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)00479-2 · Cited by 702
Pharmaceutical preformulation : the physicochemical properties of drug substances
Wells, J. I. (1988) · E. Horwood , Halsted Press eBooks · Cited by 387
The hydrophobic-subtraction model of reversed-phase column selectivity
SNYDER, L., DOLAN, J., & CARR, P. (2004) · Journal of Chromatography A · doi:10.1016/s0021-9673(04)01480-3 · Cited by 338
McCalley, D. V. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.09.047 · Cited by 304
Self-citationThe hydrophobic-subtraction model of reversed-phase column selectivity
Snyder, L. R., Dolan, J. W., & Carr, P. W. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.08.121 · Cited by 298
Euerby, M. R., & Petersson, P. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00393-5 · Cited by 280
Gritti, F., Cavazzini, A., Marchetti, N., & Guiochon, G. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.030 · Cited by 258
D. Antia, F., & Horváth, C. (1988) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)82158-0 · Cited by 254
Köhler, J., Chase, D. B., Farlee, R. D., Vega, A. J., & Kirkland, J. J. (1986) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)83386-0 · Cited by 248
High-Temperature Ultrafast Liquid Chromatography
Yan, B., Zhao, J., Brown, J. S., Blackwell, J., & Carr, P. W. (2000) · Analytical Chemistry · doi:10.1021/ac991008y · Cited by 176
Column selectivity in reversed-phase liquid chromatography
Gilroy, J. J., Dolan, J. W., & Snyder, L. R. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00512-0 · Cited by 165
Pereira, A. D. S., David, F., Vanhoenacker, G., & Sandra, P. J. F. (2009) · Journal of Separation Science · doi:10.1002/jssc.200900272 · Cited by 116
About the C term in the van Deemter's equation of plate height in monoliths
SIOUFFI, A. M. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.036 · Cited by 105
Effect of buffer on peak shape of peptides in reversed-phase high performance liquid chromatography
McCalley, D. V. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.03.038 · Cited by 93
Self-citationMarchand, D. H., Snyder, L. R., & Dolan, J. W. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.079 · Cited by 77
Cabooter, D., Lestremau, F., Lynen, F., Sandra, P. J. F., & Desmet, G. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.09.106 · Cited by 74
Effect of anionic additive type on ion pair formation constants of basic pharmaceuticals
Dai, J., Mendonsa, S. D., Bowser, M. T., Lucy, C. A., & Carr, P. W. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.02.030 · Cited by 66
Samuelsson, J., Franz, A., Stanley, B. J., & Fornstedt, T. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.06.026 · Cited by 64
Gritti, F. G., & Guiochon, G. A. (2006) · Analytical Chemistry · doi:10.1021/ac060392d · Cited by 48
Gritti, F. G., & Guiochon, G. A. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.11.020 · Cited by 47
Davies, N. H., Euerby, M. R., & McCalley, D. V. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.11.040 · Cited by 45
Self-citationInvestigation of Anion Retention and Cation Exclusion Effects for Several C18 Stationary Phases
Loeser, E., & Drumm, P. (2007) · Analytical Chemistry · doi:10.1021/ac0704816 · Cited by 31
Euerby, M. R., Johnson, C. M., Rushin, I. D., & Tennekoon, D. A. S. S. (1995) · Journal of Chromatography A · doi:10.1016/0021-9673(95)00273-p · Cited by 30
Cited by
NORMAN guidance on suspect and non-target screening in environmental monitoring
Hollender, J., Schymanski, E. L., Ahrens, L., Alygizakis, N., Béen, F., Bijlsma, L., Brunner, A. M., Celma, A., Fildier, A., Fu, Q., et al. (2023) · Environmental Sciences Europe · doi:10.1186/s12302-023-00779-4 · Cited by 278
Comprehensive Overview of Bottom-Up Proteomics Using Mass Spectrometry
Jiang, Y., Rex, D. A. B., Schuster, D., Neely, B. A., Rosano, G. L., Volkmar, N., Momenzadeh, A., Peters-Clarke, T. M., Egbert, S. B., Kreimer, S., et al. (2024) · ACS Measurement Science Au · doi:10.1021/acsmeasuresciau.3c00068 · Cited by 190
Tan, T., Zhang, M., Wan, Y., & Qiu, H. (2016) · Talanta · doi:10.1016/j.talanta.2015.11.041 · Cited by 144
Marclay, F., & Saugy, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.10.005 · Cited by 67
Metadata
- Authors
- McCalley, D. V.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2010-02
- Volume
- 1217
- Issue
- 6
- Pages
- 858-880
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W2081194480
- Cited by
- 235
- References
- 28
- FWCI
- 8.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.