Analysis of volatile aldehyde biomarkers in human blood by derivatization and dispersive liquid–liquid microextraction based on solidification of floating organic droplet method by high performance liquid chromatography
Abstract
A new dispersive liquid-liquid microextraction based on solidification of floating organic droplet method (DLLME-SFO) was developed for the determination of volatile aldehyde biomarkers (hexanal and heptanal) in human blood samples. In the derivatization and extraction procedure, 2,4-dinitrophenylhydrazine (DNPH) as derivatization reagent and formic acid as catalyzer were injected into the sample solution for derivatization with aldehydes, then the formed hydrazones was rapidly extracted by dispersive liquid-liquid microextraction with 1-dodecanol as extraction solvent. After centrifugation, the floated droplet was solidified in an ice bath and was easily removed for analysis. The effects of various experimental parameters on derivatization and extraction conditions were studied, such as the kind and volume of extraction solvent and dispersive solvent, the amount of derivatization reagent, derivatization temperature and time, extraction time and salt effect. The limit of detections (LODs) for hexanal and heptanal were 7.90 and 2.34nmolL(-1), respectively. Good reproducibility and recovery of the method were also obtained. The proposed method is an alternative approach to the quantification of volatile aldehyde biomarkers in complex biological samples, being more rapid and simpler and providing higher sensitivity compared with the traditional dispersive liquid-liquid microextraction (DLLME) methods.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Lv et al [30] used LPME-SFO method combined with derivatization for the determination of hexanal and heptanal in human blood samples via HPLC.”
From Developments in Liquid-phase Microextraction Method Based on Solidification of Floating Organic Drop (2010) · cites this paper as [30]
In the citing paper
“The recoveries of the target analytes from real samples were 67.8%-70.2%.”
From Developments in Liquid-phase Microextraction Method Based on Solidification of Floating Organic Drop (2010) · cites this paper as [30]
In the citing paper
“The RSDs of intraday and inter-day were below 4.11% and 2.91%, respectively.”
From Developments in Liquid-phase Microextraction Method Based on Solidification of Floating Organic Drop (2010) · cites this paper as [30]
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Rezaei, F., Bidari, A., Birjandi, A. P., Milani Hosseini, M. R., & Assadi, Y. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.02.005 · Cited by 164
Xu, H., Song, D., Cui, Y., Hu, S., Yu, Q.-W., & Feng, Y.-Q. (2009) · Chromatographia · doi:10.1365/s10337-009-1208-7 · Cited by 37
Self-citation
Research works printed but not linked: 41
- Otson, 1988, Sci. Total Environ., 77, 95, 10.1016/0048-9697(88)90049-6 · DOI
- Pillai, 2009, Anal. Chim. Acta, 632, 208, 10.1016/j.aca.2008.11.021 · DOI
- Stashenko, 2000, J. Chromatogr. A, 886, 175, 10.1016/S0021-9673(00)00479-9 · DOI
- St. Angelo, 1996, Crit. Rev. Food Sci. Nutr., 36, 175, 10.1080/10408399609527723 · DOI
- O’Brien, 2005, Crit. Rev. Toxicol., 35, 609, 10.1080/10408440591002183 · DOI
- Kubatova, 2004, Environ. Toxicol. Chem., 23, 2243, 10.1897/03-613 · DOI
- Reynolds, 2003, Environ. Health Perspect., 111, 663, 10.1289/ehp.5986 · DOI
- Deng, 2004, J. Chromatogr. B, 813, 47, 10.1016/j.jchromb.2004.09.007 · DOI
- Chi, 2007, Talanta, 72, 539, 10.1016/j.talanta.2006.11.018 · DOI
- Hang Ho, 2002, Anal. Chem., 74, 1232, 10.1021/ac015708q · DOI
- Saitoh, 2006, J. Chromatogr. A, 1134, 38, 10.1016/j.chroma.2006.09.002 · DOI
- Beránek, 2008, J. Chromatogr. A, 1209, 44, 10.1016/j.chroma.2008.09.013 · DOI
- Eugenia Bãnos, 2009, J. Chromatogr. A, 1216, 6554, 10.1016/j.chroma.2009.08.004 · DOI
- Svensson, 2007, J. Chromatogr. B, 860, 86, 10.1016/j.jchromb.2007.10.021 · DOI
- Gaspar, 2009, J. Chromatogr. A, 1216, 2749, 10.1016/j.chroma.2008.10.125 · DOI
- Andreoli, 2003, Rapid Commun. Mass Spectrom., 17, 637, 10.1002/rcm.960 · DOI
- Zhang, 2007, J. Chromatogr. A, 1160, 114, 10.1016/j.chroma.2007.04.015 · DOI
- Li, 2005, Anal. Biochem., 342, 318, 10.1016/j.ab.2005.04.024 · DOI
- Xue, 2008, Rapid Commun. Mass Spectrom., 22, 1181, 10.1002/rcm.3466 · DOI
- Zhang, 2006, Anal. Chim. Acta, 565, 129, 10.1016/j.aca.2006.02.050 · DOI
- Leeuwen, 2004, J. Chromatogr. A, 1058, 107, 10.1016/j.chroma.2004.08.149 · DOI
- Cancilla, 1992, J. Chromatogr., 627, 1, 10.1016/0021-9673(92)87181-7 · DOI
- Schmarr, 2008, Anal. Chim. Acta, 617, 119, 10.1016/j.aca.2008.02.002 · DOI
- Fiamegos, 2008, Anal. Chim. Acta, 609, 175, 10.1016/j.aca.2007.12.042 · DOI
- Stashenko, 2000, J. Chromatogr. A, 886, 175, 10.1016/S0021-9673(00)00479-9 · DOI
- Arthur, 1990, Anal. Chem., 62, 2145, 10.1021/ac00218a019 · DOI
- Wang, 2005, J. Chromatogr. A, 1071, 147, 10.1016/j.chroma.2004.09.031 · DOI
- Helena, 1999, Trends Anal. Chem., 18, 272, 10.1016/S0165-9936(98)00109-5 · DOI · Paper page
- Shin, 2009, J. Chromatogr. B, 877, 3707, 10.1016/j.jchromb.2009.09.022 · DOI
- Deng, 2004, J. Chromatogr. B, 808, 269, 10.1016/j.jchromb.2004.05.015 · DOI
- Deng, 2004, Rapid Commun. Mass Spectrom., 18, 1715, 10.1002/rcm.1544 · DOI
- Fiamegos, 2007, Anal. Chim. Acta, 599, 76, 10.1016/j.aca.2007.07.068 · DOI
- Basheer, 2004, J. Chromatogr. A, 1022, 161, 10.1016/j.chroma.2003.09.043 · DOI
- Cruz-Vera, 2008, J. Chromatogr. A, 1202, 1, 10.1016/j.chroma.2008.06.035 · DOI
- Yang, 2007, J. Chromatogr. A, 1164, 56, 10.1016/j.chroma.2007.07.019 · DOI
- Cui, 2009, J. Chromatogr. A, 1216, 2241, 10.1016/j.chroma.2009.01.022 · DOI
- Chen, 2009, Anal. Chim. Acta, 632, 80, 10.1016/j.aca.2008.10.068 · DOI · Paper page
- Xiong, 2009, J. Pharma. Biomed. Anal., 49, 572, 10.1016/j.jpba.2008.11.036 · DOI · Paper page
- Moinfar, 2009, J. Hazard. Mater., 69, 907, 10.1016/j.jhazmat.2009.04.030 · DOI · Paper page
- Leong, 2008, J. Chromatogr. A, 1211, 8, 10.1016/j.chroma.2008.09.111 · DOI · Paper page
- Xu, 2009, Anal. Chim. Acta, 636, 28, 10.1016/j.aca.2009.01.028 · DOI · Paper page
Cited by
Sorted by citations
Volatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways
Hakim, M., Broza, Y. Y., Barash, O., Peled, N., Phillips, M., Amann, A., & Haick, H. (2012) · Chemical Reviews · doi:10.1021/cr300174a · Cited by 953
Kocúrová, L., Balogh, I. S., Šandrejová, J., & Andruch, V. (2012) · Microchemical Journal · doi:10.1016/j.microc.2011.12.002 · Cited by 271
Recent development and applications of dispersive liquid–liquid microextraction
Yan, H., & Wang, H. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.04.053 · Cited by 256
Recent developments in dispersive liquid–liquid microextraction
Saraji, M., & Boroujeni, M. K. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7467-z · Cited by 232
“In situ derivatization by 2,4-dinitrophenylhydriazine and DLLME for the determination of formaldehyde in beverages [110], sulfonamides [100], and volatile aldehydes [203] has also been reported.”
BackgroundRecent advances in applications of single-drop microextraction: A review
Jain, A., & Verma, K. K. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.08.022 · Cited by 193
Metadata
- Authors
- Lili, L., Xu, H., Song, D., Cui, Y., Hu, S., & Zhang, G.
- Affiliations
- Central China Normal University (CN)
- Hubei Cancer Hospital (CN)
- Hubei University (CN)
- Corresponding author
- Xu, Hui
- Zhang, Ganbing
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2010-04
- Volume
- 1217
- Issue
- 16
- Pages
- 2365-2370
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W2093027155
- Cited by
- 123
- References
- 0
- Citations by year
- 2026: 5 · 2025: 2 · 2024: 1 · 2023: 3 · 2022: 4 · 2021: 3 · 2020: 1 · 2019: 8 · 2018: 4 · 2017: 5 · 2016: 10 · 2015: 12 · 2014: 6 · 2013: 20 · 2012: 17
- FWCI
- 18.74
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Chromatography A (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- hexanal, heptanal, human blood, dispersive liquid-liquid microextraction, solidification of floating organic droplet, 2,4-dinitrophenylhydrazine derivatization, hydrazones, derivatization optimization, oxidative stress biomarkers
- MeSH terms
- Aldehydes, Chromatography, High Pressure Liquid, Chemical Fractionation, Humans, Dodecanol, Phenylhydrazines, Sensitivity and Specificity, Sodium Chloride, Solvents, Time, Reproducibility of Results, Linear Models, Volatile Organic Compounds
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review