Hydrophobic borneol-based natural deep eutectic solvents as a green extraction media for air-assisted liquid-liquid micro-extraction of warfarin in biological samples
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
In the present study, a new generation of water-immiscible natural deep eutectic solvents (DESs) was synthesized using borneol as a hydrogen-bonding acceptor and decanoic acid, oleic acid, and thymol as a hydrogen-bonding donor in different molar ratios. These green hydrophobic solvents which are chemically stable in aqueous solutions were used as extraction solvents for isolation and pre-concentration of warfarin in biological samples. In this method, fine droplets of DESs were dispersed into the sample solution by using the air-assisted liquid-liquid micro-extraction method to accelerate the cloudy emulsion system formation and increase the mass transfer of the analyte to the DES-rich phase. The borneol based deep eutectic solvent is a worthy generation of the extraction solvents in the ALLME method due to low-cost and less toxicity. A Plackett-Burman design was utilized for screening the experimental parameters. The effective parameters were then optimized by Box-Behnken design (BBD). Optimized extraction conditions were pH of sample solution of 3.9, number of aspiration/dispersion cycles of 15, the volume of DES of 60 μL, and rate and time of centrifuge of 6000 rpm and 10 min, respectively. Under the optimized conditions, the developed NADES-ALLME method exhibited a wide linear range of 5-500 µg L - 1 for plasma and urine samples with satisfactory recoveries above 88.80%. Limit of detections (LODs) and Limit of quantifications (LOQs) of warfarin were in the ranges of 0.5-2.7 and 1.65-8.91, respectively. The enrichment factors were obtained in the range of 148-164 and precisions were lower than 5.87%. Finally, the proposed method was successfully employed for the analysis of warfarin in human urine and plasma samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Hydrophobic deep eutectic solvents as water-immiscible extractants
van Osch, D. J. G. P., Zubeir, L. F., van den Bruinhorst, A., Rocha, M. A. A., & Kroon, M. C. (2015) · Green Chemistry · doi:10.1039/c5gc01451d · Cited by 987
Menthol-based Eutectic Mixtures: Hydrophobic Low Viscosity Solvents
Ribeiro, B. D., Florindo, C., Iff, L. C., Coelho, M. A. Z., & Marrucho, I. M. (2015) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.5b00532 · Cited by 672
Low melting mixtures in organic synthesis–an alternative to ionic liquids?
Ruß, C., & König, B. (2012) · Green Chemistry · doi:10.1039/c2gc36005e · Cited by 654
Regueiro, J., Llompart, M., Garcia-Jares, C., Garcia-Monteagudo, J. C., & Cela, R. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.02.091 · Cited by 547
Florindo, C., Branco, L. C., & Marrucho, I. M. (2017) · Fluid Phase Equilibria · doi:10.1016/j.fluid.2017.04.002 · Cited by 457
Makoś, P., Przyjazny, A., & Boczkaj, G. (2018) · Journal of Chromatography A · doi:10.1016/j.chroma.2018.07.070 · Cited by 342
Ionic liquids in dispersive liquid-liquid microextraction
Trujillo-Rodríguez, M. J., Rocío-Bautista, P., Pino, V., & Afonso, A. M. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.06.008 · Cited by 276
Kocúrová, L., Balogh, I. S., Šandrejová, J., & Andruch, V. (2012) · Microchemical Journal · doi:10.1016/j.microc.2011.12.002 · Cited by 271
Deep eutectic solvent-based dispersive liquid-liquid microextraction
Farajzadeh, M. A., Afshar Mogaddam, M. R., & Aghanassab, M. (2016) · Analytical Methods · doi:10.1039/c5ay03189c · Cited by 141
Research works printed but not linked: 35
- Hadjmohammadi, 2012, Three-phase hollow fiber liquid phase microextraction of warfarin from human plasma and its determination by high-performance liquid chromatography, J. Pharm. Biomed. Anal., 61, 44, 10.1016/j.jpba.2011.11.019 · DOI
- Denooz, 2009, Fatal intoxications by acenocoumarol, phenprocoumon and warfarin: method validation in blood using the total error approach, J. Chromatogr. B, 877, 2344, 10.1016/j.jchromb.2008.11.049 · doi:10.1016/j.jchromb.2008.11.049
- Huang, 2008, Measurement of free concentrations of highly protein-bound warfarin in plasma by ultra-performance liquid chromatography–tandem mass spectrometry and its correlation with the international normalized ratio, Clin. Chim. Acta, 393, 85, 10.1016/j.cca.2008.03.008 · DOI
- Hadjmohammadi, 2017, Solvent bar microextraction using a reverse micelle containing extraction phase for the determination of warfarin from human plasma by high-performance liquid chromatography, J. Chromatogr. A, 1496, 1, 10.1016/j.chroma.2017.03.037 · DOI
- Dumas, 2007, Warfarin dosing and the promise of pharmacogenomics, Curr. Clin. Pharmacol., 2, 11, 10.2174/157488407779422276 · DOI
- Sun, 2006, Study on warfarin plasma concentration and its correlation with international normalized ratio, J. Pharm. Biomed. Anal., 42, 218, 10.1016/j.jpba.2006.03.019 · doi:10.1016/j.jpba.2006.03.019
- Rosengren, 2012, Monitoring the distribution of warfarin in blood plasma, ACS. Med. Chem. Lett., 3, 650, 10.1021/ml300112e · doi:10.1021/ml300112e
- Coe, 2006, Supercritical fluid chromatography–tandem mass spectrometry for fast bioanalysis of R/S-warfarin in human plasma, J. Pharm. Biomed. Anal., 42, 573, 10.1016/j.jpba.2006.05.025 · DOI
- Boppana, 2002, High-performance liquid-chromatographic determination of warfarin enantiomers in plasma with automated on-line sample enrichment, J. Biochem. Biophys. Methods, 54, 315, 10.1016/S0165-022X(02)00122-7 · doi:10.1016/s0165-022x(02)00122-7
- Ring, 2000, Validation of a method for the determination of (R)-warfarin and (S)-warfarin in human plasma using LC with UV detection, J. Pharm. Biomed. Anal, 22, 573, 10.1016/S0731-7085(00)00232-6 · doi:10.1016/s0731-7085(00)00232-6
- Locatelli, 2005, Determination of warfarin enantiomers and hydroxylated metabolites in human blood plasma by liquid chromatography with achiral and chiral separation, J. Chromatogr. B, 818, 191, 10.1016/j.jchromb.2004.12.024 · doi:10.1016/j.jchromb.2004.12.024
- Lomonaco, 2013, Determination of total and unbound warfarin and warfarin alcohols in human plasma by high performance liquid chromatography with fluorescence detection, J. Chromatogr. A, 1314, 54, 10.1016/j.chroma.2013.08.091 · DOI
- Osman, 2005, A new high-performance liquid chromatographic method for determination of warfarin enantiomers, J. Chromatogr. B, 826, 75, 10.1016/j.jchromb.2005.08.011 · doi:10.1016/j.jchromb.2005.08.011
- Miura, 2011, Simultaneous determination of warfarin and 7-hydroxywarfarin enantiomers by high-performance liquid chromatography with ultraviolet detection, Ther Drug Monit, 33, 108, 10.1097/FTD.0b013e31820176d6 · DOI
- Zhang, 2001, Quantitative liquid chromatography/mass spectrometry/mass spectrometry warfarin assay for in vitro cytochrome P450 studies, Anal. Biochem., 298, 40, 10.1006/abio.2001.5383 · DOI
- Naidong, 2001, Development and validation of a sensitive and robust LC–tandem MS method for the analysis of warfarin enantiomers in human plasma, J. Pharm. Biomed. Anal., 25, 219, 10.1016/S0731-7085(00)00476-3 · doi:10.1016/s0731-7085(00)00476-3
- Balchen, 2007, Electrokinetic migration of acidic drugs across a supported liquid membrane, J. Chromatogr. A, 1152, 220, 10.1016/j.chroma.2006.10.096 · DOI · Paper page
- Gareil, 1993, Separation and determination of warfarin enantiomers in human plasma samples by capillary zone electrophoresis using a methylated β-cyclodextrin-containing electrolyte, J. Chromatogr, 615, 317, 10.1016/0378-4347(93)80347-7 · doi:10.1016/0378-4347(93)80347-7
- Hou, 2007, Separation and determination of warfarin enantiomers in human plasma using a novel polymeric surfactant for micellar electrokinetic chromatography–mass spectrometry, J. Chromatogr. A, 1159, 208, 10.1016/j.chroma.2007.04.037 · doi:10.1016/j.chroma.2007.04.037
- Asfaram, 2019, Magnetic dispersive micro-solid phase extraction with the CuO/ZnO@ Fe3O4-CNTs nanocomposite sorbent for the rapid pre-concentration of chlorogenic acid in the medical extract of plants, food, and water samples, Analyst, 144, 2684, 10.1039/C8AN02484G · DOI
- Mehrabi, 2017, Ultrasound assisted extraction of maxilon red GRL dye from water samples using cobalt ferrite nanoparticles loaded on activated carbon as sorbent: optimization and modeling, Ultrason Sonochem, 38, 672, 10.1016/j.ultsonch.2016.08.012 · DOI
- Barfi, 2015, Comparison of ultrasound-enhanced air-assisted liquid–liquid microextraction and low-density solvent-based dispersive liquid–liquid microextraction methods for determination of nonsteroidal anti-inflammatory drugs in human urine samples, J. Pharm. Biomed. Anal., 111, 297, 10.1016/j.jpba.2015.03.034 · DOI
- Yiantzi, 2010, Vortex-assisted liquid–liquid microextraction of octylphenol, nonylphenol and bisphenol-A, Talanta, 80, 2057, 10.1016/j.talanta.2009.11.005 · DOI · Paper page
- Farajzadeh, 2012, Air-assisted liquid–liquid microextraction method as a novel microextraction technique; application in extraction and preconcentration of phthalate esters in aqueous sample followed by gas chromatography–flame ionization detection, Anal Chim Acta, 728, 31, 10.1016/j.aca.2012.03.031 · DOI · Paper page
- Abbott, 2003, Novel solvent properties of choline chloride/urea mixtures, Chem. Comm., 70, 10.1039/b210714g · DOI · Paper page
- Zhang, 2012, Deep eutectic solvents: syntheses, properties and applications, Chem. Soc. Rev., 41, 7108, 10.1039/c2cs35178a · DOI · Paper page
- Majidi, 2019, J. Sep. Sci., 17, 2743
- Li, 2019, Utilization of deep eutectic solvents in dispersive liquid-liquid micro-extraction, Trends Anal. Chem.
- Lee, 2019, Hydrophobic deep eutectic solvents for the extraction of organic and inorganic analytes from aqueous environments, Trends Anal. Chem., 10.1016/j.trac.2019.07.008 · DOI · Paper page
- Li, 2020, New low viscous hydrophobic deep eutectic solvents in vortex-assisted liquid-liquid microextraction for the determination of phthalate esters from food-contacted plastics, Food Chem., 309, 10.1016/j.foodchem.2019.125752 · DOI · Paper page
- Saraji, 2014, Extraction of methocarbamol from human plasma with a polypyrrole/multiwalled carbon nanotubes composite decorated with magnetic nanoparticles as an adsorbent followed by electrospray ionization ion mobility spectrometry detection, J. Sep. Sci., 37, 3518, 10.1002/jssc.201400614 · doi:10.1002/jssc.201400614
- Aghaie, 2016, Fe3O4@ p-Naphtholbenzein as a novel nano-sorbent for highly effective removal and recovery of berberine: response surface methodology for optimization of ultrasound assisted dispersive magnetic solid phase extraction, Talanta, 156, 18, 10.1016/j.talanta.2016.04.034 · DOI
- Ghambari, 2012, Low-density solvent-based dispersive liquid–liquid microextraction followed by high performance liquid chromatography for determination of warfarin in human plasma, J. Chromatogr. B, 899, 66, 10.1016/j.jchromb.2012.04.035 · DOI
- Peyrovi, 2015, Supramolecular solvent-based microextraction of warfarin from biological samples and its determination using HPLC, J. Iran Chem. Soc., 12, 1253, 10.1007/s13738-015-0589-9 · DOI
- Jin, 2006, Determination of warfarin and coumatetralyl in serum by hplc coupled with electrospray ionization mass spectrometry, J. Liq. Chromatogr. Relat. Technol., 29, 2641, 10.1080/10826070600923043 · doi:10.1080/10826070600923043
Cited by
Cao, J., & Su, E. (2021) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2021.127965 · Cited by 345
Microextraction Techniques with Deep Eutectic Solvents
Plastiras, O.-E., Andreasidou, E., & Samanidou, V. (2020) · Molecules · doi:10.3390/molecules25246026 · Cited by 84
Atypical Deep Eutectic Solvents: New Opportunities for Chemical Analysis
Shishov, A., El-Deen, A. K., Godunov, P., & Bulatov, A. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117752 · Cited by 51
Guo, K., Wu, X., Zhang, F., Cao, Y., Tan, Z., Xiao, S., & Wu, L. (2024) · Molecules · doi:10.3390/molecules29143423 · Cited by 13
“…for the preconcentration and separation of organic pollutants such as methadone [17], heavy metals [18], endocrine disrupting chemicals [19], pesticides [20], aromatic amines [21], oxyprenylated phenylpropanoids [22], and warfarin [23] in environmental samples, food, and biological samples.”
BackgroundZhu, X., Geng, S., Wen, T., Qin, F., & Zhao, L. (2021) · Analytical Methods · doi:10.1039/d1ay01218e · Cited by 12
Metadata
- Authors
- Majidi, S. M., & Hadjmohammadi, M. R.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2020-06
- Volume
- 1621
- Pages
- 461030
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W3011400639
- Cited by
- 59
- References
- 14
- FWCI
- 3.96
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- doi.org/10.15223/policy-017 (stm-asf)
- doi.org/10.15223/policy-037 (stm-asf)
- doi.org/10.15223/policy-012 (stm-asf)
- doi.org/10.15223/policy-029 (stm-asf)
- doi.org/10.15223/policy-004 (stm-asf)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hydrophobic borneol-based natural deep eutectic solvents as a green extraction media for air-assisted liquid-liquid micro-extraction of warfarin in biological samples. https://app.cochat.ai/papers/10.1016/j.chroma.2020.461030
- The paper
- Majidi, S. M., & Hadjmohammadi, M. R. (2020). Hydrophobic borneol-based natural deep eutectic solvents as a green extraction media for air-assisted liquid-liquid micro-extraction of warfarin in biological samples. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2020.461030
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.