The DOI matches its Crossref record; 233 of the 235 references it cites were found in a registry or an index.
Magnetic fluid hyperthermia: Focus on superparamagnetic iron oxide nanoparticles
Open accessAbstract
Due to their unique magnetic properties, excellent biocompatibility as well as multi-purpose biomedical potential (e.g., applications in cancer therapy and general drug delivery), superparamagnetic iron oxide nanoparticles (SPIONs) are attracting increasing attention in both pharmaceutical and industrial communities. The precise control of the physiochemical properties of these magnetic systems is crucial for hyperthermia applications, as the induced heat is highly dependent on these properties. In this review, the limitations and recent advances in the development of superparamagnetic iron oxide nanoparticles for hyperthermia are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Interestingly, Guardia et al. observed a linear SAR dependence as a function of frequency (at a fixed amplitude) and a quadratic SAR dependence as a function of amplitude (at a fixed frequency) for water-soluble iron oxide nanocubes [15, 115].”
From Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications (2019) · cites this paper as [15]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Understanding biophysicochemical interactions at the nano–bio interface
Nel, A. E., Mädler, L., Velegol, D., Xia, T., Hoek, E. M. V., Somasundaran, P., Klaessig, F., Castranova, V., & Thompson, M. (2009) · Nature Materials · doi:10.1038/nmat2442 · Cited by 7,083
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Self-citationApplications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Connolly, J., Jones, S. K., & Dobson, J. (2003) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/36/13/201 · Cited by 5,974
A mechanism of magnetic hysteresis in heterogeneous alloys
Stoner, E. C., & Wohlfarth, E. P. (1948) · Philosophical Transactions of the Royal Society of London Series A Mathematical and Physical Sciences · doi:10.1098/rsta.1948.0007 · Cited by 5,429
Ultra-large-scale syntheses of monodisperse nanocrystals
Park, J., An, K., Hwang, Y., Park, J.-G., Noh, H.-J., Kim, J.-Y., Park, J.-H., Hwang, N.-M., & Hyeon, T. (2004) · Nature Materials · doi:10.1038/nmat1251 · Cited by 4,076
Monodisperse MFe2O4 (M = Fe, Co, Mn) Nanoparticles
Sun, S., Zeng, H., Robinson, D., Raoux, S., Rice, P. M., Wang, S. X., & Li, G. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0380852 · Cited by 3,484
Thermal Fluctuations of a Single-Domain Particle
Brown, W. F. (1963) · Physical Review · doi:10.1103/physrev.130.1677 · Cited by 3,374
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Springer eBooks · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,571
Heating magnetic fluid with alternating magnetic field
Rosensweig, R. E. (2002) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(02)00706-0 · Cited by 2,552
Nanoparticle and targeted systems for cancer therapy
Brannon‐Peppas, L., & Blanchette, J. O. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.02.014 · Cited by 2,335
Research works printed but not linked: 9
- Maier-Hauff, 2010, Efficacy and safety of intratumoral thermotherapy using magnetic iron-oxide nanoparticles combined with external beam radiotherapy on patients with recurrent glioblastoma multiforme, J Neuro Oncol, 1
- Johannsen, 2007, Thermal therapy of prostate cancer using magnetic nanoparticles, Termoterapia ccer de prstata mediate el uso de nanopartculas magnticas, 31, 660
- Neel, 1949, Théorie du trainage magnétique des ferromagnétiques en grains fins avec applications aux terres cuites, Ann Géophys, 5, 99
- Jacobs, 1963, vol. 3, 271
- Chikazumi, 1984, vol. 2
- Brezovich, 1988, Low frequency hyperthermia: capacitive and ferromagnetic thermoseed methods, Med Phys Monogr Med Phys, 16, 82
- Hergt, 2002, Magnetic nanoparticles for thermoablation, Recent Res Dev Mater Sci, 3, 723
- Carroll, 2003, Development of magnetothermal responsive systems for tumor treatment, Proc Int Symp Control Rel Bioact Mater, 30, 82
- Ruiz, 1991, J Control Release, 86, 5
Cited by
Sorted by citations
Wu, W., Wu, Z., Yu, T., Jiang, C., & Kim, W.-S. (2015) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/16/2/023501 · Cited by 1,574
Sapsford, K. E., Algar, W. R., Berti, L., Gemmill, K. B., Casey, B. J., Oh, E., Stewart, M. H., & Medintz, I. L. (2013) · Chemical Reviews · doi:10.1021/cr300143v · Cited by 1,470
Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications
Dadfar, S. M., Roemhild, K., Drude, N. I., von Stillfried, S., Knüchel, R., Kiessling, F., & Lammers, T. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.01.005 · Cited by 1,181
Iron Oxide Based Nanoparticles for Multimodal Imaging and Magnetoresponsive Therapy
Lee, N., Yoo, D., Ling, D., Cho, M. H., Hyeon, T., & Cheon, J. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00112 · Cited by 1,020
Yao, J., Yang, M., & Duan, Y. (2014) · Chemical Reviews · doi:10.1021/cr200359p · Cited by 960
Metadata
- Authors
- Laurent, S., Dutz, S., Häfeli, U. O., & Mahmoudi, M.
- Affiliations
- University of Mons (BE)
- University of British Columbia (CA)
- Pasteur Institute of Iran (IR)
- Corresponding author
- Mahmoudi, Morteza
- Venue
- Advances in Colloid and Interface Science
- Publisher
- Elsevier BV
- Published
- 2011-08
- Volume
- 166
- Issue
- 1-2
- Pages
- 8-23
- ISSN
- 0001-8686 (ISSN-L)
- OpenAlex
- W2014777534
- Cited by
- 1,326
- References
- 235
- Citations by year
- 2026: 37 · 2025: 56 · 2024: 45 · 2023: 70 · 2022: 96 · 2021: 113 · 2020: 113 · 2019: 112 · 2018: 94 · 2017: 119 · 2016: 124 · 2015: 106 · 2014: 94 · 2013: 76 · 2012: 59
- FWCI
- 6.14
- Type
- journal article
- Language
- en
- Open access
- green
- orbi.umons.ac.be
- Licence
- Locations
- Advances in Colloid and Interface Science (publishedVersion)
- PubMed (publishedVersion)
- ORBi UMONS (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Physical Sciences › Materials Science › Materials Chemistry › Magnetic Properties and Synthesis of Ferrites
- Physical Sciences › Materials Science › Biomaterials › Nanoparticle-Based Drug Delivery
- Keywords
- magnetic hyperthermia, superparamagnetic iron oxide nanoparticles, magnetic nanoparticles, cancer therapy, drug delivery, biocompatibility, physicochemical properties, heat generation, nanoparticle synthesis
- MeSH terms
- Animals, Humans, Hyperthermia, Induced, Magnetics, Materials Testing, Temperature, Drug Delivery Systems, Chemical Phenomena, Magnetite Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review