Mechanical properties of the human patellar tendon, in vivo
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635 · cited 1×
“Paired student s t-test (systematic error), Pearson correlation coefficient (strength of the relationship) and typical error percent for duplicate measures were used to analyze reproducibility (Hopkins, 2000).”
MethodButler, D. L., Kay, M. D., & Stouffer, D. C. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90019-9 · Cited by 513 · cited 2×
“Human patellar tendon modulus, and stress and strain at failure has been reported to be 340–850 MPa, 65–78 MPa and 12%–16%, respectively, using isolated human cadaver tissue (Butler et al., 1986; Flahiff et al., 1995; Johnson et al., 1994).”
BackgroundEffect of strength training on human patella tendon mechanical properties of older individuals
Reeves, N. D., Maganaris, C. N., & Narici, M. V. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2002.035576 · Cited by 484
Effect of strength training on human patella tendon mechanical properties of older individuals
Reeves, N. D., Maganaris, C. N., & Narici, M. V. (2003) · The Journal of Physiology · doi:10.1111/j..2003.t01-1-00971.x · Cited by 484 · cited 3×
“These pilot data are in accordance with a previous report (Reeves et al., 2003).”
BackgroundMethodResultInfluentialLength and moment arm of human leg muscles as a function of knee and hip-joint angles
Visser, J. J., Hoogkamer, J. E., Bobbert, M. F., & Huijing, P. A. (1990) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00236067 · Cited by 429 · cited 1×
“from individually measured femur lengths (Visser et al., 1990).”
Tensile and viscoelastic properties of human patellar tendon
Johnson, G. A., Tramaglini, D. M., Levine, R. E., Ohno, K., Choi, N., & L‐Y. Woo, S. (1994) · Journal of Orthopaedic Research · doi:10.1002/jor.1100120607 · Cited by 417 · cited 2×
“Human patellar tendon modulus, and stress and strain at failure has been reported to be 340–850 MPa, 65–78 MPa and 12%–16%, respectively, using isolated human cadaver tissue (Butler et al., 1986; Flahiff et al., 1995; Johnson et al., 1994).”
BackgroundButler, D. L., Grood, E. S., Noyes, F. R., Zernicke, R. F., & Brackett, K. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90090-3 · Cited by 386 · cited 1×
“Alternatively, the present methodology avoids stress concentration and tissue slippage associated with isolated tissue testing (Butler et al., 1984; Haraldsson et al., 2005), and may explain the lower strain and consequently greater modulus values of the present study.”
BackgroundMechanical properties of various mammalian tendons
Bennett, M. B., Ker, R. F., Imery, N. J., & Alexander, R. M. (1986) · Journal of Zoology · doi:10.1111/j.1469-7998.1986.tb03609.x · Cited by 368 · cited 1×
“At the same time, the modulus of the human patellar tendon in vivo was greater ( 1 GPa) than that reported for isolated human patellar tendon but similar to various animal tendons at comparable magnitude of stress (Bennett et al., 1986).”
BackgroundKubo, K., Kanehisa, H., & Fukunaga, T. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2001.012703 · Cited by 312 · cited 1×
“However, ultrasonography is an attractive non-invasive method for studying human, in vivo, muscle-tendon behaviour, which has been used extensively in recent years to examine Achilles tendon properties (Kubo et al., 2002; Maganaris and Paul, 2002; Magnusson et al., 2003).”
MethodTensile properties of the in vivo human gastrocnemius tendon
Maganaris, C. N., & Paul, J. P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00240-3 · Cited by 305 · cited 1×
“However, ultrasonography is an attractive non-invasive method for studying human, in vivo, muscle-tendon behaviour, which has been used extensively in recent years to examine Achilles tendon properties (Kubo et al., 2002; Maganaris and Paul, 2002; Magnusson et al., 2003).”
Method
Cited by
Kongsgaard, M., Kovanen, V., Aagaard, P., Doessing, S., Hansen, P., Laursen, A. H., Kaldau, N. C., Kjaer, M., & Magnusson, S. P. (2009) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2009.00949.x · Cited by 471
Self-citationRegion specific patellar tendon hypertrophy in humans following resistance training
Kongsgaard, M., Reitelseder, S., Pedersen, T. G., Holm, L., Aagaard, P., Kjaer, M., & Magnusson, S. P. (2007) · Acta Physiologica · doi:10.1111/j.1748-1716.2007.01714.x · Cited by 377
Self-citationHuman tendon behaviour and adaptation, in vivo
Magnusson, S. P., Narici, M. V., Maganaris, C. N., & Kjaer, M. (2008) · The Journal of Physiology · doi:10.1113/jphysiol.2007.139105 · Cited by 330
Self-citationHabitual loading results in tendon hypertrophy and increased stiffness of the human patellar tendon
Couppé, C., Kongsgaard, M., Aagaard, P., Hansen, P., Bojsen-Moller, J., Kjaer, M., & Magnusson, S. P. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90361.2008 · Cited by 289
Self-citationDe Boer, M. D., Maganaris, C. N., Seynnes, O. R., Rennie, M. J., & Narici, M. V. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2007.135392 · Cited by 283
Seynnes, O. R., Erskine, R. M., Maganaris, C. N., Longo, S., Simoneau, E. M., Grosset, J. F., & Narici, M. V. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00213.2009 · Cited by 268
Increasing Running Step Rate Reduces Patellofemoral Joint Forces
LENHART, R. L., THELEN, D. G., WILLE, C. M., CHUMANOV, E. S., & HEIDERSCHEIT, B. C. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182a78c3a · Cited by 257
Mechanical properties and collagen cross-linking of the patellar tendon in old and young men
Couppé, C., Hansen, P., Kongsgaard, M., Kovanen, V., Suetta, C., Aagaard, P., Kjær, M., & Magnusson, S. P. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00291.2009 · Cited by 256
Self-citationFarrokhi, S., Keyak, J. H., & Powers, C. M. (2011) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2010.12.001 · Cited by 249
Arampatzis, A., Peper, A., Bierbaum, S., & Albracht, K. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.08.014 · Cited by 218
Kongsgaard, M., Qvortrup, K., Larsen, J., Aagaard, P., Doessing, S., Hansen, P., Kjaer, M., & Magnusson, S. P. (2010) · The American Journal of Sports Medicine · doi:10.1177/0363546509350915 · Cited by 212
“Details and reliability of this method have been reported previously.(13,18) Briefly, synchronized values of patellar tendon elongation (DL), obtained from ultrasound recordings, and patellar tendon forces (DF) were sampled.”
Self-citationInfluence of aging on the in vivo properties of human patellar tendon
Carroll, C. C., Dickinson, J. M., Haus, J. M., Lee, G. A., Hollon, C. J., Aagaard, P., Magnusson, S. P., & Trappe, T. A. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00059.2008 · Cited by 186
“Tendon force was calculated by dividing the total knee extension moment by the internal moment arm, which was estimated from femur length (14, 58).”
InfluentialSelf-citationCouppé, C., Svensson, R. B., Grosset, J.-F., Kovanen, V., Nielsen, R. H., Olsen, M. R., Larsen, J. O., Praet, S. F. E., Skovgaard, D., Hansen, M., et al. (2014) · AGE · doi:10.1007/s11357-014-9665-9 · Cited by 109
Self-citationMechano-Immunomodulation: Mechanoresponsive Changes in Macrophage Activity and Polarization
Adams, S., Wuescher, L. M., Worth, R., & Yildirim-Ayan, E. (2019) · Annals of Biomedical Engineering · doi:10.1007/s10439-019-02302-4 · Cited by 96
Seynnes, O. R., Kamandulis, S., Kairaitis, R., Helland, C., Campbell, E.-L., Brazaitis, M., Skurvydas, A., & Narici, M. V. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01417.2012 · Cited by 80
Foam Rolling Training Effects on Range of Motion: A Systematic Review and Meta-Analysis
Konrad, A., Nakamura, M., Tilp, M., Donti, O., & Behm, D. G. (2022) · Sports Medicine · doi:10.1007/s40279-022-01699-8 · Cited by 72
Metadata
- Authors
- Hansen, P., Bojsen-Moller, J., Aagaard, P., Kjaer, M., & Magnusson, S. P.
- Venue
- Clinical Biomechanics
- Publisher
- Elsevier BV
- Published
- 2006-01
- Volume
- 21
- Issue
- 1
- Pages
- 54-58
- ISSN
- 0268-0033 (ISSN-L)
- OpenAlex
- W1983170657
- Cited by
- 175
- References
- 16
- FWCI
- 6.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.