Kinematic trajectories while walking within the Lokomat robotic gait-orthosis
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adaptive representation of dynamics during learning of a motor task
Shadmehr, R., & Mussa-Ivaldi, F. (1994) · The Journal of Neuroscience · doi:10.1523/jneurosci.14-05-03208.1994 · Cited by 2,612 · cited 1×
“We estimate that each subject took approximately 500 steps over more than 20 min between comparisons, at a variety of speeds, which should have resulted in changes in the motor program ( Shadmehr and Mussa-Ivaldi, 1994 ) or di!erences in leg kinematics (Gordon and Ferris, 2007).”
BackgroundTreadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,292
Biomechanics of overground vs. treadmill walking in healthy individuals
Lee, S. J., & Hidler, J. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01380.2006 · Cited by 595 · cited 1×
“Previous research has suggested that, from a rehabilitation perspective, treadmill walking patterns are similar to overground walking patterns (Lee and Hidler, 2008).”
BackgroundSelf-citationAge-related changes in speed of walking
HIMANN, J. E., CUNNINGHAM, D. A., RECHNITZER, P. A., & PATERSON, D. H. (1988) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198820020-00010 · Cited by 512 · cited 2×
“It should be noted that this speed range was selected since the Lokomat best operates over these conditions, and has a top speed of 3.2 km/h, even though normal overground walking speeds are in the 4.5–4.9 km/h range (Himann et al, 1988).”
BackgroundInfluentialWirz, M., Zemon, D. H., Rupp, R., Scheel, A., Colombo, G., Dietz, V., & Hornby, T. G. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2004.08.004 · Cited by 479 · cited 2×
“E-mail address: hidler@cua.edu (J. Hidler). spinal cord injured subjects (ASIA C-D) demonstrated improvements in walking ability, endurance, and lower extremity function (Wirz et al., 2005).”
BackgroundHusemann, B., Müller, F., Krewer, C., Heller, S., & Koenig, E. (2007) · Stroke · doi:10.1161/01.str.0000254607.48765.cb · Cited by 418 · cited 1×
“Similar effects have been reported in incomplete spinal cord injury (SCI) (Hornby et al., 2005) acute brain injured subjects (Mayr et al, 2002), and acute stroke (Husemann et al, 2007; Mayr et al, 2007).”
Mayr, A., Kofler, M., Quirbach, E., Matzak, H., Fröhlich, K., & Saltuari, L. (2007) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968307300697 · Cited by 371 · cited 2×
“Similar e!ects have been reported in incomplete spinal cord injury (SCI) (Hornby et al., 2005) acute brain injured subjects (Mayr et al, 2002), and acute stroke (Husemann et al, 2007; Mayr et al, 2007 ).”
Learning to walk with a robotic ankle exoskeleton
Gordon, K. E., & Ferris, D. P. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.12.006 · Cited by 318 · cited 1×
“We estimate that each subject took approximately 500 steps over more than 20 min between comparisons, at a variety of speeds, which should have resulted in changes in the motor program (Shadmehr and MussaIvaldi, 1994) or differences in leg kinematics (Gordon and Ferris, 2007).”
BackgroundAlterations in muscle activation patterns during robotic-assisted walking
Hidler, J. M., & Wall, A. E. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2004.09.016 · Cited by 309 · cited 2×
“This is consistent with the changes in EMG patterns we observed in our previous study where there was elevated activity in the Rectus Femoris during early to mid swing when subjects walked in the Lokomat (Hidler and Wall, 2005).”
MethodResultSelf-citationHornby, T. G., Zemon, D. H., & Campbell, D. (2005) · Physical Therapy · doi:10.1093/ptj/85.1.52 · Cited by 283 · cited 1×
“Similar effects have been reported in incomplete spinal cord injury (SCI) (Hornby et al., 2005) acute brain injured subjects (Mayr et al, 2002), and acute stroke (Husemann et al, 2007; Mayr et al, 2007).”
Advances in the Understanding and Treatment of Stroke Impairment Using Robotic Devices
Hidler, J., Nichols, D., Pelliccio, M., & Brady, K. (2005) · Topics in Stroke Rehabilitation · doi:10.1310/ryt5-62n4-ctvx-8jte · Cited by 171 · cited 2×
“In recent years, the field of neurorehabilitation has been adopting robotic devices to help deliver mass-practice therapy to individuals with various types of neurological disorders (see Hidler et al., 2005 for review).”
BackgroundSelf-citationCai, L. L., Fong, A. J., Otoshi, C. K., Liang, Y., Cham, J. G., Zhong, H., Roy, R. R., Edgerton, V. R., & Burdick, J. W. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1502028 · Cited by 25 · cited 3×
“…studies have suggested that training under a variable step pattern is more effective at improving step patterns than walking with a fixed, continuous step trajectory (Cai et al., 2005), so it would be advantageous to know how much the subject’s leg moves within the Lokomat during a step sequence.”
BackgroundInfluentialInverse-Dynamics Based Assessment of Gait using a Robotic Orthosis
Hidler, J. M., & Neckel, N. D. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259392 · Cited by 21 · cited 1×
“Individual stride cycles were determined for each 30 s trial using the vertical ground reaction force data, where each stride was considered the period between successive heel-strikes in the same leg (Hidler and Neckel, 2006).”
MethodSelf-citation
Cited by
Multicenter Randomized Clinical Trial Evaluating the Effectiveness of the Lokomat in Subacute Stroke
Hidler, J., Nichols, D., Pelliccio, M., Brady, K., Campbell, D. D., Kahn, J. H., & Hornby, T. G. (2009) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968308326632 · Cited by 652
Self-citationA Review on Lower Limb Rehabilitation Exoskeleton Robots
Shi, D., Zhang, W., Zhang, W., & Ding, X. (2019) · Chinese Journal of Mechanical Engineering · doi:10.1186/s10033-019-0389-8 · Cited by 508
Pilot study of Lokomat versus manual-assisted treadmill training for locomotor recovery post-stroke
Westlake, K. P., & Patten, C. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-18 · Cited by 330
Wagner, J., Solis-Escalante, T., Grieshofer, P., Neuper, C., Müller-Putz, G., & Scherer, R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.08.019 · Cited by 301
Towards more effective robotic gait training for stroke rehabilitation: a review
Pennycott, A., Wyss, D., Vallery, H., Klamroth-Marganska, V., & Riener, R. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-65 · Cited by 259
Metadata
- Authors
- Hidler, J., Wisman, W., & Neckel, N.
- Venue
- Clinical Biomechanics
- Publisher
- Elsevier BV
- Published
- 2008-12
- Volume
- 23
- Issue
- 10
- Pages
- 1251-1259
- ISSN
- 0268-0033 (ISSN-L)
- OpenAlex
- W2164331190
- Cited by
- 190
- References
- 13
- FWCI
- 5.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.