Tolerance of the lumbar spine to shear: A review and recommended exposure limits
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Revised NIOSH equation for the design and evaluation of manual lifting tasks
WATERS, T. R., PUTZ-ANDERSON, V., GARG, A., & FINE, L. J. (1993) · Ergonomics · doi:10.1080/00140139308967940 · Cited by 2,042
Thompson, W. A., & Nelson, W. (1983) · Journal of the American Statistical Association · doi:10.2307/2288691 · Cited by 1,476
Clinical Anatomy of the Lumbar Spine and Sacrum
Bogduk, N. (1997) · Cited by 747
Norman, R., Wells, R., Neumann, P., Frank, J., Shannon, H., & Kerr, M. (1998) · Clinical Biomechanics · doi:10.1016/s0268-0033(98)00020-5 · Cited by 658 · cited 1×
“These authors in conjunction with others (Norman et al., 1998) suggested an action limit (AL), representing an unacceptable risk to most workers without engineering or administrative controls, of 500 N.”
BackgroundAdams, M. A. (2004) · Acupuncture in Medicine · doi:10.1136/aim.22.4.178 · Cited by 578
A Study of Three Preventive Approaches to Low Back Injury
Snook, S. H., Campanelli, R. A., & Hart, J. W. (1978) · Journal of Occupational and Environmental Medicine · doi:10.1097/00043764-197807000-00009 · Cited by 300 · cited 1×
“Such an approach has been used in setting psychophysically-based standards (Snook et al., 1978) and the National Institute for Occupational Safety and Health revised Lifting Equation (Waters et al.”
MethodFatigue fracture of human lumbar vertebrae
Brinckmann, P., Biggemann, M., & Hilweg, D. (1988) · Clinical Biomechanics · doi:10.1016/s0268-0033(88)80001-9 · Cited by 299 · cited 3×
“The most likely cause of damage is fatigue failure (Brinckmann et al., 1988; Gallagher et al., 2005); however, on occasion the spine's ultimate compressive strength may be exceeded.”
BackgroundFarley, T. M. M., & Nelson, W. (1983) · Biometrics · doi:10.2307/2531130 · Cited by 272 · cited 2×
“A regression analysis was conducted to calculate the median rank for each life value (Nelson, 1982).”
MethodGallagher, S., & Heberger, J. R. (2013) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720812449648 · Cited by 236
Self-citationIn Vitro fatigue of Human Tendons
Schechtman, H., & Bader, D. L. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00033-x · Cited by 218 · cited 3×
“It should be noted in this regard that the fatigue failure curve is logarithmic in nature; thus, relatively small decreases in stress on the tissues can lead to substantial increases in fatigue life at lower force levels (Schechtman and Bader, 1997).”
Background
Cited by
Risk Assessment of Work-Related Musculoskeletal Disorders in Construction: State-of-the-Art Review
Wang, D., Dai, F., & Ning, X. (2015) · Journal of Construction Engineering and Management · doi:10.1061/(asce)co.1943-7862.0000979 · Cited by 274
Metadata
- Authors
- Gallagher, S., & Marras, W. S.
- Venue
- Clinical Biomechanics
- Publisher
- Elsevier BV
- Published
- 2012-12
- Volume
- 27
- Issue
- 10
- Pages
- 973-978
- ISSN
- 0268-0033 (ISSN-L)
- OpenAlex
- W2042950921
- Cited by
- 218
- References
- 17
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tolerance of the lumbar spine to shear: A review and recommended exposure limits. https://app.cochat.ai/papers/10.1016/j.clinbiomech.2012.08.009
- The paper
- Gallagher, S., & Marras, W. S. (2012). Tolerance of the lumbar spine to shear: A review and recommended exposure limits. Clinical Biomechanics. https://doi.org/10.1016/j.clinbiomech.2012.08.009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.