Spike detection: Inter-reader agreement and a statistical Turing test on a large data set
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Compare the spike detection performance of three skilled humans and three computer algorithms. METHODS: 40 prolonged EEGs, 35 containing reported spikes, were evaluated. Spikes and sharp waves were marked by the humans and algorithms. Pairwise sensitivity and false positive rates were calculated for each human-human and algorithm-human pair. Differences in human pairwise performance were calculated and compared to the range of algorithm versus human performance differences as a type of statistical Turing test. RESULTS: 5474 individual spike events were marked by the humans. Mean, pairwise human sensitivities and false positive rates were 40.0%, 42.1%, and 51.5%, and 0.80, 0.97, and 1.99/min. Only the Persyst 13 (P13) algorithm was comparable to humans - 43.9% and 1.65/min. Evaluation of pairwise differences in sensitivity and false positive rate demonstrated that P13 met statistical noninferiority criteria compared to the humans. CONCLUSION: Humans had only a fair level of agreement in spike marking. The P13 algorithm was statistically noninferior to the humans. SIGNIFICANCE: This was the first time that a spike detection algorithm and humans performed similarly. The performance comparison methodology utilized here is generally applicable to problems in which skilled human performance is the desired standard and no external gold standard exists.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
I.—COMPUTING MACHINERY AND INTELLIGENCE
TURING, A. M. (1950) · Mind · doi:10.1093/mind/lix.236.433 · Cited by 10,290 · cited 1×
“This paradigm functions as a statistical Turing test (Turing, 1950) to evaluate whether a particular algorithm performs in a manner indistinguishable from skilled human readers.”
BackgroundTesting Statistical Hypotheses of Equivalence and Noninferiority
Wellek, S. (2010) · doi:10.1201/ebk1439808184 · Cited by 548 · cited 1×
“Here we use the term noninferiority to denote absence of a relevant difference in spike detection sensitivity and false positive rate between the skilled human readers and a spike detection algorithm (see Wellek for discussion of noninferiority (Wellek, 2010)).”
Method
Cited by
Automated Interpretation of Clinical Electroencephalograms Using Artificial Intelligence
Tveit, J., Aurlien, H., Plis, S., Calhoun, V. D., Tatum, W. O., Schomer, D. L., Arntsen, V., Cox, F., Fahoum, F., Gallentine, W. B., et al. (2023) · JAMA Neurology · doi:10.1001/jamaneurol.2023.1645 · Cited by 242
Association of epileptiform abnormalities and seizures in Alzheimer disease.
Lam, A. D., Sarkis, R. A., Pellerin, K. R., Jing, J., Dworetzky, B. A., Hoch, D. B., Jacobs, C. S., Lee, J. W., Weisholtz, D. S., Zepeda, R., et al. (2020) · Neurology · doi:10.1212/wnl.0000000000010612 · Cited by 172
Predicting sex from brain rhythms with deep learning
van Putten, M. J. A. M., Olbrich, S., & Arns, M. (2018) · Scientific Reports · doi:10.1038/s41598-018-21495-7 · Cited by 169
“…frequently applied to brain imaging data, including electroencephalography (EEG), with applications ranging from characterization of the EEG background pattern 18,19 or quantification of focal or global ischaemia 20–22 to detection of epileptiform discharges 23,24 and diagnostics in depression 16 .”
MethodMachine learning and wearable devices of the future
Beniczky, S., Karoly, P., Nurse, E., Ryvlin, P., & Cook, M. (2021) · Epilepsia · doi:10.1111/epi.16555 · Cited by 155
Fürbass, F., Kural, M. A., Gritsch, G., Hartmann, M., Kluge, T., & Beniczky, S. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.02.032 · Cited by 106
Metadata
- Authors
- Scheuer, M. L., Bagic, A., & Wilson, S. B.
- Venue
- Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 2017-01
- Volume
- 128
- Issue
- 1
- Pages
- 243-250
- ISSN
- 1388-2457 (ISSN-L)
- OpenAlex
- W2553360915
- Cited by
- 154
- References
- 2
- FWCI
- 7.44
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.