Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 277

The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.

Multiplex PCR system for the rapid diagnosis of respiratory virus infection: systematic review and meta-analysis

Open access
Huang, H.-S., Tsai, C.-L., Chang, J., Hsu, T.-C., Lin, S., Lee, C.-C.·2018·Clinical Microbiology and Infection

Abstract

Objectives To provide a summary of evidence for the diagnostic accuracies of three multiplex PCR systems (mPCRs)—BioFire FilmArray RP (FilmArray), Nanosphere Verigene RV+ test (Verigene RV+) and Hologic Gen-Probe Prodesse assays—on the detection of viral respiratory infections. Methods A comprehensive search up to 1 July 2017 was conducted on Medline and Embase for studies that utilized FilmArray, Verigene RV+ and Prodesse for diagnosis of viral respiratory infections. A summary of diagnostic accuracies for the following five viruses were calculated: influenza A virus (FluA), influenza B virus, respiratory syncytial virus, human metapneumovirus and adenovirus. Hierarchical summary receiver operating curves were used for estimating the viral detection performance per assay. Results Twenty studies of 5510 patient samples were eligible for analysis. Multiplex PCRs demonstrated high diagnostic accuracy, with area under the receiver operating characteristic curve (AUROC) equal to or more than 0.98 for all the above viruses except for adenovirus (AUROC 0.89). FilmArray, Verigene RV+ and ProFlu+ (the only Prodesse assay with enough data) demonstrated a summary sensitivity for FluA of 0.911 (95% confidence interval, 0.848–0.949), 0.949 (95% confidence interval, 0.882–0.979) and 0.954 (95% confidence interval, 0.871–0.985), respectively. The three mPCRs were comparable in terms of detection of FluA. Conclusions Point estimates calculated from eligible studies showed that the three mPCRs (FilmArray, Verigene RV+ and ProFlu+) are highly accurate and may provide important diagnostic information for early identification of respiratory virus infections. In patients with low pretest probability for FluA, these three mPCRs can predict a low possibility of infection and may justify withholding empirical antiviral treatments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cmi.2017.11.018

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

1 retracted

Show all 44 references

Cited by

See all 277

Metadata

Authors
Huang, H.-S., Tsai, C.-L., Chang, J., Hsu, T.-C., Lin, S., & Lee, C.-C.
Venue
Clinical Microbiology and Infection
Publisher
Elsevier BV
Published
2018-10
Volume
24
Issue
10
Pages
1055-1063
ISSN
1198-743X (ISSN-L)
OpenAlex
W2773052864
Cited by
277
References
44
FWCI
2.17
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multiplex PCR system for the rapid diagnosis of respiratory virus infection: systematic review and meta-analysis. https://app.cochat.ai/papers/10.1016/j.cmi.2017.11.018
The paper
Huang, H.-S., Tsai, C.-L., Chang, J., Hsu, T.-C., Lin, S., & Lee, C.-C. (2018). Multiplex PCR system for the rapid diagnosis of respiratory virus infection: systematic review and meta-analysis. Clinical Microbiology and Infection. https://doi.org/10.1016/j.cmi.2017.11.018

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.