Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 220

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Non-invasive brain stimulation and neuroenhancement

Open access
Antal, Andrea, Luber, Bruce, Brem, Anna-Katharine, Bikson, Marom, Brunoni, Andre R., Cohen Kadosh, Roi, Dubljević, Veljko, Fecteau, Shirley, Ferreri, Florinda, Flöel, Agnes, Hallett, Mark, Hamilton, Roy H., Herrmann, Christoph S., Lavidor, Michal, Loo, Collen, Lustenberger, Caroline, Machado, Sergio, Miniussi, Carlo, Moliadze, Vera, Nitsche, Michael A, Rossi, Simone, Rossini, Paolo M., Santarnecchi, Emiliano, Seeck, Margitta, Thut, Gregor, Turi, Zsolt, Ugawa, Yoshikazu, Venkatasubramanian, Ganesan, Wenderoth, Nicole, Wexler, Anna, Ziemann, Ulf, Paulus, Walter·2022·Clinical Neurophysiology Practice

Abstract

Attempts to enhance human memory and learning ability have a long tradition in science. This topic has recently gained substantial attention because of the increasing percentage of older individuals worldwide and the predicted rise of age-associated cognitive decline in brain functions. Transcranial brain stimulation methods, such as transcranial magnetic (TMS) and transcranial electric (tES) stimulation, have been extensively used in an effort to improve cognitive functions in humans. Here we summarize the available data on low-intensity tES for this purpose, in comparison to repetitive TMS and some pharmacological agents, such as caffeine and nicotine. There is no single area in the brain stimulation field in which only positive outcomes have been reported. For self-directed tES devices, how to restrict variability with regard to efficacy is an essential aspect of device design and function. As with any technique, reproducible outcomes depend on the equipment and how well this is matched to the experience and skill of the operator. For self-administered non-invasive brain stimulation, this requires device designs that rigorously incorporate human operator factors. The wide parameter space of non-invasive brain stimulation, including dose (e.g., duration, intensity (current density), number of repetitions), inclusion/exclusion (e.g., subject's age), and homeostatic effects, administration of tasks before and during stimulation, and, most importantly, placebo or nocebo effects, have to be taken into account. The outcomes of stimulation are expected to depend on these parameters and should be strictly controlled. The consensus among experts is that low-intensity tES is safe as long as tested and accepted protocols (including, for example, dose, inclusion/exclusion) are followed and devices are used which follow established engineering risk-management procedures. Devices and protocols that allow stimulation outside these parameters cannot claim to be "safe" where they are applying stimulation beyond that examined in published studies that also investigated potential side effects. Brain stimulation devices marketed for consumer use are distinct from medical devices because they do not make medical claims and are therefore not necessarily subject to the same level of regulation as medical devices (i.e., by government agencies tasked with regulating medical devices). Manufacturers must follow ethical and best practices in marketing tES stimulators, including not misleading users by referencing effects from human trials using devices and protocols not similar to theirs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cnp.2022.05.002

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Metadata

Authors
Antal, A., Luber, B., Brem, A.-K., Bikson, M., Brunoni, A. R., Cohen Kadosh, R., Dubljević, V., Fecteau, S., Ferreri, F., Flöel, A., Hallett, M., Hamilton, R. H., Herrmann, C. S., Lavidor, M., Loo, C., Lustenberger, C., Machado, S., Miniussi, C., Moliadze, V., Nitsche, M. A., Rossi, S., Rossini, P. M., Santarnecchi, E., Seeck, M., Thut, G., Turi, Z., Ugawa, Y., Venkatasubramanian, G., Wenderoth, N., Wexler, A., Ziemann, U., & Paulus, W.
Venue
Clinical Neurophysiology Practice
Publisher
Elsevier BV
Published
2022
Volume
7
Pages
146-165
ISSN
2467-981X (ISSN-L)
OpenAlex
W4281486035
Cited by
220
References
24
FWCI
13.31
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Non-invasive brain stimulation and neuroenhancement. https://app.cochat.ai/papers/10.1016/j.cnp.2022.05.002
The paper
Antal, A., Luber, B., Brem, A.-K., Bikson, M., Brunoni, A. R., Cohen Kadosh, R., Dubljević, V., Fecteau, S., Ferreri, F., Flöel, A., Hallett, M., Hamilton, R. H., Herrmann, C. S., Lavidor, M., Loo, C., Lustenberger, C., Machado, S., Miniussi, C., Moliadze, V., . . . Paulus, W. (2022). Non-invasive brain stimulation and neuroenhancement. Clinical Neurophysiology Practice. https://doi.org/10.1016/j.cnp.2022.05.002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.