Measuring local pH in electrochemistry
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Localized pH measurements are important in various areas of electrochemistry, from corrosion to bio-electrochemistry and electrocatalysis. Different techniques are available to perform these measurements and offer numerous possibilities in terms of spatial and temporal resolution, sensitivity, and precision. In this brief review we present the recent progress made and summarize the main techniques available for localized pH measurements in electrochemistry such as scanning probe techniques (SECM, SICM, SIET), laser (confocal) fluorescence microscopy, rotating ring-disc electrode (RRDE) voltammetry, and infra-red spectroscopy, among others.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthesis of clathrate cerium superhydride CeH9 at 80-100 GPa with atomic hydrogen sublattice
Salke, N. P., Davari Esfahani, M. M., Zhang, Y., Kruglov, I. A., Zhou, J., Wang, Y., Greenberg, E., Prakapenka, V. B., Liu, J., Oganov, A. R., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-12326-y · Cited by 1,004
Fluorescent bioimaging of pH: from design to applications
Hou, J.-T., Ren, W. X., Li, K., Seo, J., Sharma, A., Yu, X.-Q., & Kim, J. S. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00719h · Cited by 557
Wencel, D., Abel, T., & McDonagh, C. (2014) · Analytical Chemistry · doi:10.1021/ac4035168 · Cited by 541
Metal oxides based electrochemical pH sensors: Current progress and future perspectives
Manjakkal, L., Szwagierczak, D., & Dahiya, R. (2020) · Progress in Materials Science · doi:10.1016/j.pmatsci.2019.100635 · Cited by 481
Ooka, H., Figueiredo, M. C., & Koper, M. T. M. (2017) · Langmuir · doi:10.1021/acs.langmuir.7b00696 · Cited by 422
Self-citationScanning Electrochemical Microscopy
(2012) · CRC Press eBooks · doi:10.1201/b11850 · Cited by 346
Zhang, F., & Co, A. C. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201912637 · Cited by 298
Yang, K., Kas, R., & Smith, W. A. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b07000 · Cited by 288
pH Matters When Reducing CO2 in an Electrochemical Flow Cell
Zhang, Z., Melo, L., Jansonius, R. P., Habibzadeh, F., Grant, E. R., & Berlinguette, C. P. (2020) · ACS Energy Letters · doi:10.1021/acsenergylett.0c01606 · Cited by 266
Ayemoba, O., & Cuesta, A. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b07351 · Cited by 256
Aerosol microdroplets exhibit a stable pH gradient
Wei, H., Vejerano, E. P., Leng, W., Huang, Q., Willner, M. R., Marr, L. C., & Vikesland, P. J. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1720488115 · Cited by 252
Intracellular pH is a tightly controlled signal in yeast
Orij, R., Brul, S., & Smits, G. J. (2011) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2011.03.011 · Cited by 243 · cited 1×
“[2] Various biological processes cause intra- or extracellular pH changes and the quantification of these pH changes can help to understand the associated mecha nisms .[3] Numerous electrocatalytic processes such as O 2 evolution or CO2 reduction, that consume or produce H + or OH , generate a pH gradient between the…”
BackgroundKorostynska, O., Arshak, K., Gill, E., & Arshak, A. (2007) · Sensors · doi:10.3390/s7123027 · Cited by 184 · cited 1×
“They are mainly b ased on metals, metal/metal oxides (TiO 2, RuO2, RhO2, Ta2O5, IrO2, PtO2, and ZrO2)[6] or electrodeposited polymer films.[7] Among th ese, IrO2 is the most popular substrate.”
BackgroundDesign principles of spectroscopic probes for biological applications
Zhou, J., & Ma, H. (2016) · Chemical Science · doi:10.1039/c6sc02500e · Cited by 155
Nadappuram, B. P., McKelvey, K., Botros, R. A., Colburn, A. W., & Unwin, P. R. (2013) · Analytical Chemistry · doi:10.1021/ac401883n · Cited by 131
Zhang, X., Ogorevc, B., & Wang, J. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)01435-0 · Cited by 128
Surface pH measurements during nickel electrodeposition
Ji, J., Cooper, W. C., Dreisinger, D. B., & Peters, E. (1995) · Journal of Applied Electrochemistry · doi:10.1007/bf00241925 · Cited by 116
Iridium oxide fabrication and application: A review
Jang, H., & Lee, J. (2019) · Journal of Energy Chemistry · doi:10.1016/j.jechem.2019.10.026 · Cited by 109 · cited 1×
“Alth ough there is an extensive list of synthesis protocols reported in l iterature[12], the Jo urn al Pr e-p roo f”
BackgroundHigh-resolution label-free 3D mapping of extracellular pH of single living cells
Zhang, Y., Takahashi, Y., Hong, S. P., Liu, F., Bednarska, J., Goff, P. S., Novák, P., Shevchuk, A., Gopal, S., Barozzi, I., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-13535-1 · Cited by 107
Boldt, F. M., Heınze, J., Diez, M., Petersen, J., & Börsch, M. (2004) · Analytical Chemistry · doi:10.1021/ac049635x · Cited by 83
Yokoyama, Y., Miyazaki, K., Miyahara, Y., Fukutsuka, T., & Abe, T. (2019) · ChemElectroChem · doi:10.1002/celc.201900759 · Cited by 74
Mediator-Free SECM for Probing the Diffusion Layer pH with Functionalized Gold Ultramicroelectrodes
Monteiro, M. C. O., Jacobse, L., Touzalin, T., & Koper, M. T. M. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04952 · Cited by 71
Self-citationHighly stable SERS pH nanoprobes produced by co-solvent controlled AuNP aggregation
Wei, H., Willner, M. R., Marr, L. C., & Vikesland, P. J. (2016) · The Analyst · doi:10.1039/c6an00650g · Cited by 67
Lamaka, S. V., Taryba, M. G., Montemor, M. F., Isaacs, H. S., & Ferreira, M. G. S. (2010) · Electrochemistry Communications · doi:10.1016/j.elecom.2010.11.002 · Cited by 66
Сергеевич, Г. А., Mei, D., Lamaka, S. V., Sinebryukhov, S. L., Mashtalyar, D. V., Vyaliy, I. E., Zheludkevich, M. L., & Gnedenkov, S. V. (2020) · Corrosion Science · doi:10.1016/j.corsci.2020.108689 · Cited by 62
SRpHi ratiometric pH biosensors for super-resolution microscopy
Richardson, D. S., Gregor, C., Winter, F. R., Urban, N. T., Sahl, S. J., Willig, K. I., & Hell, S. W. (2017) · Nature Communications · doi:10.1038/s41467-017-00606-4 · Cited by 61
Joshi, V. S., Sheet, P. S., Cullin, N., Kreth, J., & Koley, D. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03050 · Cited by 61
Monteiro, M. C. O., Jacobse, L., & Koper, M. T. M. (2020) · The Journal of Physical Chemistry Letters · doi:10.1021/acs.jpclett.0c02779 · Cited by 53
Self-citationPande, N., Chandrasekar, S. K., Lohse, D., Mul, G., Wood, J. A., Mei, B., & Krug, D. J. (2020) · The Journal of Physical Chemistry Letters · doi:10.1021/acs.jpclett.0c01575 · Cited by 53
In situ pH measurements with hydrous iridium oxide in a rotating ring disc configuration
Steegstra, P., & Ahlberg, E. (2012) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2012.07.040 · Cited by 52
Tefashe, U. M., Dauphin‐Ducharme, P., Danaie, M., Cano, Z. P., Kish, J. R., Botton, G. A., & Mauzeroll, J. (2015) · Journal of The Electrochemical Society · doi:10.1149/2.0601510jes · Cited by 33
Real-time monitoring of extracellular pH using a pH-potentiometric sensing SECM dual-microelectrode
Song, R., Xiong, Q., Wu, T., Ning, X., Zhang, F., Wang, Q., & He, P. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02625-5 · Cited by 32
A versatile and robust surface-poison-resisting Scanning Amperometric Proton Microscopy
Chen, D., Penhallurick, R. W., & Tong, Y. J. (2020) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2020.113918 · Cited by 5
Cited by
Shih, A. J., Monteiro, M. C. O., Dattila, F., Pavesi, D., Philips, M., da Silva, A. H. M., Vos, R. E., Ojha, K., Park, S., van der Heijden, O., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00164-0 · Cited by 521
Self-citationReaction Environment Regulation for Electrocatalytic CO2 Reduction in Acids
Zeng, M., Fang, W., Cen, Y., Zhang, X., Hu, Y., & Xia, B. Y. (2024) · Angewandte Chemie International Edition · doi:10.1002/anie.202404574 · Cited by 213
Metadata
- Authors
- Monteiro, M. C. O., & Koper, M. T. M.
- Venue
- Current Opinion in Electrochemistry
- Publisher
- Elsevier BV
- Published
- 2021-02
- Volume
- 25
- Pages
- 100649
- ISSN
- 2451-9103 (ISSN-L)
- OpenAlex
- W3097148834
- Cited by
- 159
- References
- 33
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.