The DOI matches its Crossref record; 156 of the 156 references it cites were found in a registry or an index.
Metal oxides based electrochemical pH sensors: Current progress and future perspectives
Open accessAbstract
Electrochemical pH sensors are on high demand in numerous applications such as food processing, health monitoring, agriculture and nuclear sectors, and water quality monitoring etc., owing to their fast response (<10 s), wide pH sensing range (2–12), superior sensitivity (close to Nernstian response of 59.12 mV/pH), easy integration on wearable/flexible substrates, excellent biocompatibility and low cost of fabrication. This article presents an in-depth review of the wide range of MOx materials that have been utilized to develop pH sensors, based on various mechanisms (e.g. potentiometric, conductimetric, chemi-resistors, ion sensitive field effect transistor (ISFET) and extended-gate field effect transistor etc.). The tools and techniques such as potentiometric and electrochemical impedance spectroscopic that are commonly adopted to characterize these metal oxide-based pH sensors are also discussed in detail. Concerning materials and design of sensors for various practical application, the major challenges are toxicity of materials, interfernce of other ions or analytes, cost, and flexibility of materials. In this regard, this review also discusses the metal oxide-based composite sensing (active) material, designs of pH sensors and their applications in flexible/wearable biosensors for medical application are examined to present their suitability for these futuristic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · cited 1×
“Hence, for better performance and selectivity of the sensor, flexible multi-sensor patches, which consist of glucose, temperature and other dissolved ions monitoring electrodes on a single substrate, may be useful for sweat analysis [244,245].”
BackgroundDevelopment of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Recommendations for nomenclature of ionselective electrodes (IUPAC Recommendations 1994)
Buck, R. P., & Lindner, E. (1994) · Pure and Applied Chemistry · doi:10.1351/pac199466122527 · Cited by 1,586
Bergveld, P. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00301-5 · Cited by 1,582
Zhang, Q., Zhang, K., Xu, D., Yang, G., Huang, H., Nie, F., Liu, C., & Yang, S. (2014) · Progress in Materials Science · doi:10.1016/j.pmatsci.2013.09.003 · Cited by 1,404
Site-binding model of the electrical double layer at the oxide/water interface
Yates, D. E., Levine, S., & Healy, T. W. (1974) · Journal of the Chemical Society, Faraday Transactions 1: Physical Chemistry in Condensed Phases · doi:10.1039/f19747001807 · Cited by 1,337
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Electrochemical Impedance Spectroscopy and its Applications
Lasia, A. (2005) · Modern Aspects of Electrochemistry · doi:10.1007/0-306-46916-2_2 · Cited by 1,214
Kim, M.-G., Kanatzidis, M. G., Facchetti, A., & Marks, T. J. (2011) · Nature Materials · doi:10.1038/nmat3011 · Cited by 1,212
Cited by
Age of Flexible Electronics: Emerging Trends in Soft Multifunctional Sensors
Lee, J., Cho, K., & Kim, J. (2024) · Advanced Materials · doi:10.1002/adma.202310505 · Cited by 355
Sensors-integrated organ-on-a-chip for biomedical applications
Chen, H., Luo, Z., Lin, X., Zhu, Y., & Zhao, Y. (2023) · Nano Research · doi:10.1007/s12274-023-5651-9 · Cited by 47
Metadata
- Authors
- Manjakkal, L., Szwagierczak, D., & Dahiya, R.
- Venue
- Progress in Materials Science
- Publisher
- Elsevier BV
- Published
- 2020-04
- Volume
- 109
- Pages
- 100635
- ISSN
- 0079-6425 (ISSN-L)
- OpenAlex
- W2995212110
- Cited by
- 481
- References
- 156
- FWCI
- 25.67
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Metal oxides based electrochemical pH sensors: Current progress and future perspectives. https://app.cochat.ai/papers/10.1016/j.pmatsci.2019.100635
- The paper
- Manjakkal, L., Szwagierczak, D., & Dahiya, R. (2020). Metal oxides based electrochemical pH sensors: Current progress and future perspectives. Progress in Materials Science. https://doi.org/10.1016/j.pmatsci.2019.100635
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.