Cited by 33Polymer Surface Interaction StudiesHydrogels: synthesis, properties, applicationsMicrofluidic and Capillary Electrophoresis Applications

Uniform polydimethylsiloxane beads coated with polydopamine and their potential biomedical applications

Jun, Dae-Ryong, Moon, Seung-Kwan, Choi, Sung-Wook·2014·Colloids and Surfaces B: Biointerfaces

Abstract

Based on oil-in-water emulsion, uniform poly(dimethylsiloxane) (PDMS) beads were prepared using a simple fluidic device and then modified with polydopamine (PDA) to improve cell attachment. The size of the PDMS beads could be easily tuned by changing the flow rates of the discontinuous and continuous phases, and PDMS concentration in oil phase. The PDA-coated PDMS beads exhibited a dark and rough surface, whereas the pristine PDMS beads had a clear and smooth surface. The PDA layer at the surface of the PDMS beads was found to provide a favorable environment for cell culture due to its hydrophilic property. The PDA-coated PDMS beads can potentially be employed as filler materials for tissue engineering.

Integrity signals

Registry

Crossref · 10.1016/j.colsurfb.2014.06.027

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Such targeted modification makes the biphasic interface of material more stable and versatile for diverse requirements from bone tissue repair.

    “Such targeted modification makes the biphasic interface of material more stable and versatile for diverse requirements from bone tissue repair [97].”
  • PDA-assisted surface modification uses PDA as a biocompatible surface modifier to interact with organic and inorganic components on the interface of bone bio-substitutes.

    “PDA-assisted surface modification uses PDA as a biocompatible surface modifier to interact with organic and inorganic components on the interface of bone bio-substitutes.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Jun, D.-R., Moon, S.-K., & Choi, S.-W.
Affiliations
Catholic University of Korea (KR)
Corresponding author
Choi, Sung-Wook
Venue
Colloids and Surfaces B: Biointerfaces
Publisher
Elsevier BV
Published
2014-09
Volume
121
Pages
395-399
ISSN
0927-7765 (ISSN-L)
OpenAlex
W1973782589
Cited by
33
References
3
Citations by year
2026: 2 · 2025: 3 · 2024: 3 · 2023: 5 · 2022: 4 · 2021: 2 · 2020: 3 · 2018: 2 · 2017: 1 · 2016: 5 · 2015: 3
FWCI
1.18
Type
journal article
Language
en
Open access
closed
Locations
  • Colloids and Surfaces B Biointerfaces (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Ministry of Education, Science and Technology (2011-0023064)
  • National Research Foundation of Korea
Topics
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Medicine › Hydrogels: synthesis, properties, applications
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
Keywords
polydopamine coating, oil-in-water emulsions, fluidic devices, bead size control, cell attachment, hydrophilicity, tissue engineering scaffolds, fillers
MeSH terms
Animals, Dimethylpolysiloxanes, Indoles, Microscopy, Fluorescence, Microspheres, Particle Size, Polymers, Staining and Labeling, Spectroscopy, Fourier Transform Infrared, Coated Materials, Biocompatible, Biomedical Technology, NIH 3T3 Cells, Cell Proliferation, Mice

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review