Automated detection of atrial fibrillation using long short-term memory network with RR interval signals
The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
Atrial Fibrillation (AF), either permanent or intermittent (paroxysnal AF), increases the risk of cardioembolic stroke. Accurate diagnosis of AF is obligatory for initiation of effective treatment to prevent stroke. Long term cardiac monitoring improves the likelihood of diagnosing paroxysmal AF. We used a deep learning system to detect AF beats in Heart Rate (HR) signals. The data was partitioned with a sliding window of 100 beats. The resulting signal blocks were directly fed into a deep Recurrent Neural Network (RNN) with Long Short-Term Memory (LSTM). The system was validated and tested with data from the MIT-BIH Atrial Fibrillation Database. It achieved 98.51% accuracy with 10-fold cross-validation (20 subjects) and 99.77% with blindfold validation (3 subjects). The proposed system structure is straight forward, because there is no need for information reduction through feature extraction. All the complexity resides in the deep learning system, which gets the entire information from a signal block. This setup leads to the robust performance for unknown data, as measured with the blind fold validation. The proposed Computer-Aided Diagnosis (CAD) system can be used for long-term monitoring of the human heart. To the best of our knowledge, the proposed system is the first to incorporate deep learning for AF beat detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hochreiter, S., & Schmidhuber, J. (1997) · Neural Computation · doi:10.1162/neco.1997.9.8.1735 · Cited by 102,318
(2014) · Cited by 33,419
Deep learning in neural networks: an overview
Schmidhuber, J. (2015) · Neural Networks · doi:10.1016/j.neunet.2014.09.003 · Cited by 18,570
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Unsupervised representation learning with deep convolutional generative adversarial networks
Radford, A., Metz, L., & Chintala, S. (2015) · arXiv · doi:10.48550/arxiv.1511.06434 · Cited by 12,235 · cited 1×
“Xavier initialisation [38] was used to initialise all the weights of the model, and gradient descent backpropagation, using the Adam optimiser [39], was used to update the weights.”
MethodTensorFlow: A system for large-scale machine learning
Abadi, M., Barham, P., Chen, J., Chen, Z., Davis, A., Dean, J., Devin, M., Ghemawat, S., Irving, G., Isard, M., et al. (2016) · arXiv (Cornell University) · doi:10.48550/arxiv.1605.08695 · Cited by 11,822
Bidirectional recurrent neural networks
Schuster, M., & Paliwal, K. K. (1997) · IEEE Transactions on Signal Processing · doi:10.1109/78.650093 · Cited by 10,172 · cited 1×
“Schuster and Paliwal proposed the use of bidirectional RNNs for problems where the entire input sequence is available [33].”
BackgroundLearning long-term dependencies with gradient descent is difficult
Bengio, Y., Simard, P., & Frasconi, P. (1994) · IEEE Transactions on Neural Networks · doi:10.1109/72.279181 · Cited by 8,542 · cited 1×
“showed that, whilst standard RNNs can theoretically handle input dependencies over long-intervals, in practice training such networks with gradient descent becomes more inefficient when the temporal span of the input sequence dependencies increases [28].”
BackgroundAtrial fibrillation as an independent risk factor for stroke: the Framingham study
Wolf, P. A., Abbott, R. D., & Kannel, W. B. (1991) · Stroke · doi:10.1161/01.str.22.8.983 · Cited by 7,388
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000041 · Cited by 7,115
Cited by
Arrhythmia detection using deep convolutional neural network with long duration ECG signals
Yıldırım, Ö., Pławiak, P., Tan, R.-S., & Acharya, U. R. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.09.009 · Cited by 851
Self-citationHong, S., Zhou, Y., Shang, J., Xiao, C., & Sun, J. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103801 · Cited by 464
A review on deep learning methods for ECG arrhythmia classification
Ebrahimi, Z., Loni, M., Daneshtalab, M., & Gharehbaghi, A. (2020) · Expert Systems with Applications: X · doi:10.1016/j.eswax.2020.100033 · Cited by 447
Deep learning in ECG diagnosis: A review
Liu, X., Wang, H., Li, Z., & Qin, L. (2021) · Knowledge-Based Systems · doi:10.1016/j.knosys.2021.107187 · Cited by 436
Michielli, N., Acharya, U. R., & Molinari, F. (2019) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.01.013 · Cited by 383
Self-citationAutomated Atrial Fibrillation Detection using a Hybrid CNN-LSTM Network on Imbalanced ECG Datasets
Petmezas, G., Haris, K., Stefanopoulos, L., Kilintzis, V., Tzavelis, A., Rogers, J. A., Katsaggelos, A. K., & Maglaveras, N. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102194 · Cited by 333
Murat, F., Yildirim, O., Talo, M., Baloglu, U. B., Demir, Y., & Acharya, U. R. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103726 · Cited by 326
Self-citationAnsari, Y., Mourad, O., Qaraqe, K., & Serpedin, E. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1246746 · Cited by 291
Parkinson's disease: Cause factors, measurable indicators, and early diagnosis
Bhat, S., Acharya, U. R., Hagiwara, Y., Dadmehr, N., & Adeli, H. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.09.008 · Cited by 210
Self-citationDeep Learning-Based ECG Arrhythmia Classification: A Systematic Review
Xiao, Q., Lee, K., Mokhtar, S. A., Ismail, I., Pauzi, A. L. B. M., Zhang, Q., & Lim, P. Y. (2023) · Applied Sciences · doi:10.3390/app13084964 · Cited by 198
Rai, H. M., & Chatterjee, K. (2022) · Applied Intelligence · doi:10.1007/s10489-021-02696-6 · Cited by 182
“Faust et al. [28] proposed automated atrial fibrillation (AF) detection technique using the LSTM network on the MIT-BIH dataset with 98.51 % accuracy.”
MethodInfluentialHeart disease detection using deep learning methods from imbalanced ECG samples
Rath, A., Mishra, D., Panda, G., & Satapathy, S. C. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102820 · Cited by 179
Huang, J.-D., Wang, J., Ramsey, E., Leavey, G., Chico, T. J. A., & Condell, J. (2022) · Sensors · doi:10.3390/s22208002 · Cited by 175
Analysis of various techniques for ECG signal in healthcare, past, present, and future
Anbalagan, T., Nath, M. K., Vijayalakshmi, D., & Anbalagan, A. (2023) · Biomedical Engineering Advances · doi:10.1016/j.bea.2023.100089 · Cited by 174
A review of automated sleep stage scoring based on physiological signals for the new millennia
Faust, O., Razaghi, H., Barika, R., Ciaccio, E. J., & Acharya, U. R. (2019) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2019.04.032 · Cited by 170
“all of the available information content during both the training and the inference phases [117].”
BackgroundSelf-citationDetection of Congestive Heart Failure Based on LSTM-Based Deep Network via Short-Term RR Intervals
Wang, L., & Zhou, X. (2019) · Sensors · doi:10.3390/s19071502 · Cited by 85
“LSTM modules have received great results in the detection of time series signals, including RR interval signals [16].”
BackgroundMethodInfluential
Metadata
- Authors
- Faust, O., Shenfield, A., Kareem, M., San, T. R., Fujita, H., & Acharya, U. R.
- Venue
- Computers in Biology and Medicine
- Publisher
- Elsevier BV
- Published
- 2018-11
- Volume
- 102
- Pages
- 327-335
- ISSN
- 0010-4825 (ISSN-L)
- OpenAlex
- W2884795774
- Cited by
- 309
- References
- 59
- FWCI
- 20.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.