The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Deep Learning-Based ECG Arrhythmia Classification: A Systematic Review
Open accessAbstract
Deep learning (DL) has been introduced in automatic heart-abnormality classification using ECG signals, while its application in practical medical procedures is limited. A systematic review is performed from perspectives of the ECG database, preprocessing, DL methodology, evaluation paradigm, performance metric, and code availability to identify research trends, challenges, and opportunities for DL-based ECG arrhythmia classification. Specifically, 368 studies meeting the eligibility criteria are included. A total of 223 (61%) studies use MIT-BIH Arrhythmia Database to design DL models. A total of 138 (38%) studies considered removing noise or artifacts in ECG signals, and 102 (28%) studies performed data augmentation to extend the minority arrhythmia categories. Convolutional neural networks are the dominant models (58.7%, 216) used in the reviewed studies while growing studies have integrated multiple DL structures in recent years. A total of 319 (86.7%) and 38 (10.3%) studies explicitly mention their evaluation paradigms, i.e., intra- and inter-patient paradigms, respectively, where notable performance degradation is observed in the inter-patient paradigm. Compared to the overall accuracy, the average F1 score, sensitivity, and precision are significantly lower in the selected studies. To implement the DL-based ECG classification in real clinical scenarios, leveraging diverse ECG databases, designing advanced denoising and data augmentation techniques, integrating novel DL models, and deeper investigation in the inter-patient paradigm could be future research opportunities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Random Erasing Data Augmentation
Zhong, Z., Zheng, L., Kang, G., Li, S., & Yang, Y. (2020) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v34i07.7000 · Cited by 3,617
MLP-Mixer: An all-MLP Architecture for Vision
Tolstikhin, I., Houlsby, N., Kolesnikov, A., Beyer, L., Zhai, X., Unterthiner, T., Yung, J., Steiner, A., Keysers, D., Uszkoreit, J., et al. (2021) · arXiv · doi:10.48550/arxiv.2105.01601 · Cited by 2,087
Deep learning-based electroencephalography analysis: a systematic review
Roy, Y., Banville, H., Albuquerque, I., Gramfort, A., Falk, T. H., & Faubert, J. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab260c · Cited by 1,532
Automatic diagnosis of the 12-lead ECG using a deep neural network
Ribeiro, A. H., Ribeiro, M. H., Paixão, G. M. M., Oliveira, D. M., Gomes, P. R., Canazart, J. A., Ferreira, M. P. S., Andersson, C. R., Macfarlane, P. W., Meira, W., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-15432-4 · Cited by 894
Ma, L., & Liang, L. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105345 · Cited by 26
Cited by
Ansari, Y., Mourad, O., Qaraqe, K., & Serpedin, E. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1246746 · Cited by 291
Metadata
- Authors
- Xiao, Q., Lee, K., Mokhtar, S. A., Ismail, I., Pauzi, A. L. B. M., Zhang, Q., & Lim, P. Y.
- Venue
- Applied Sciences
- Publisher
- MDPI AG
- Published
- 2023-04-14
- Volume
- 13
- Issue
- 8
- Pages
- 4964
- ISSN
- 2076-3417 (ISSN-L)
- OpenAlex
- W4365509481
- Cited by
- 198
- References
- 5
- FWCI
- 15.53
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Deep Learning-Based ECG Arrhythmia Classification: A Systematic Review. https://app.cochat.ai/papers/10.3390/app13084964
- The paper
- Xiao, Q., Lee, K., Mokhtar, S. A., Ismail, I., Pauzi, A. L. B. M., Zhang, Q., & Lim, P. Y. (2023). Deep Learning-Based ECG Arrhythmia Classification: A Systematic Review. Applied Sciences. https://doi.org/10.3390/app13084964
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.