CoChat

Medical data quality assessment: On the development of an automated framework for medical data curation

Pezoulas, Vasileios C., Kourou, Konstantina D., Kalatzis, Fanis, Exarchos, Themis P., Venetsanopoulou, Aliki, Zampeli, Evi, Gandolfo, Saviana, Skopouli, Fotini, De Vita, Salvatore, Tzioufas, Athanasios G., Fotiadis, Dimitrios I. · 2019 · Computers in Biology and Medicine
Cited by 96

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Data quality assessment has gained attention in the recent years since more and more companies and medical centers are highlighting the importance of an automated framework to effectively manage the quality of their big data. Data cleaning, also known as data curation, lies in the heart of the data quality assessment and is a key aspect prior to the development of any data analytics services. In this work, we present the objectives, functionalities and methodological advances of an automated framework for data curation from a medical perspective. The steps towards the development of a system for data quality assessment are first described along with multidisciplinary data quality measures. A three-layer architecture which realizes these steps is then presented. Emphasis is given on the detection and tracking of inconsistencies, missing values, outliers, and similarities, as well as, on data standardization to finally enable data harmonization. A case study is conducted in order to demonstrate the applicability and reliability of the proposed framework on two well-established cohorts with clinical data related to the primary Sjögren's Syndrome (pSS). Our results confirm the validity of the proposed framework towards the automated and fast identification of outliers, inconsistencies, and highly-correlated and duplicated terms, as well as, the successful matching of more than 85% of the pSS-related medical terms in both cohorts, yielding more accurate, relevant, and consistent clinical data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.compbiomed.2019.03.001

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 96

Metadata

Authors
Pezoulas, V. C., Kourou, K. D., Kalatzis, F., Exarchos, T. P., Venetsanopoulou, A., Zampeli, E., Gandolfo, S., Skopouli, F., De Vita, S., Tzioufas, A. G., & Fotiadis, D. I.
Venue
Computers in Biology and Medicine
Publisher
Elsevier BV
Published
2019-04
Volume
107
Pages
270-283
ISSN
0010-4825 (ISSN-L)
OpenAlex
W2921039670
Cited by
96
References
4
FWCI
9.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Medical data quality assessment: On the development of an automated framework for medical data curation. https://app.cochat.ai/papers/10.1016/j.compbiomed.2019.03.001
The paper
Pezoulas, V. C., Kourou, K. D., Kalatzis, F., Exarchos, T. P., Venetsanopoulou, A., Zampeli, E., Gandolfo, S., Skopouli, F., De Vita, S., Tzioufas, A. G., & Fotiadis, D. I. (2019). Medical data quality assessment: On the development of an automated framework for medical data curation. Computers in Biology and Medicine. https://doi.org/10.1016/j.compbiomed.2019.03.001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.