Multifunctional stretchable strain sensor based on polydopamine/ reduced graphene oxide/ electrospun thermoplastic polyurethane fibrous mats for human motion detection and environment monitoring
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Abstract Various sensors have been developed to monitor the changes in physical quantities to meet the growing demand for wearable electronics. While it is still a huge challenge to design a multifunctional flexible sensor with both high strain responsivity and good breathability. In this work, through electrospinning, ultrasonication and in-situ polymerization of dopamine, we prepared a multifunctional strain sensor. We decorated polydopamine (PDA) onto the surface of reduced graphene oxide (RGO)/thermoplastic polyurethane (TPU) fibers. Here, PDA containing hydrophilic groups (-OH, –NH2) was used to improve the hydrophilic breathability of the membrane and prevent the RGO falling off from TPU fibrous mat. The PDA/RGO/TPU (PRT) fibrous strain sensor exhibits excellent comprehensive performance of excellent stretchability, good durability (stretching/releasing test of 9000 cycles under 50% strain), high sensitivity (gauge factor (GF) 23.2 within 60% strain, 185 towards 60%–100% strain), and fast response time (100 m s). Specially, owing to the introduction of PDA, the water vapor volatilization rate of our PRT strain sensor (38%) is almost the same as the blank control group (39%), indicating that our fibrous sensor has excellent breathability. In order to monitor various movements of human body parts (finger, wrist, elbow, and leg bending), our sensors were attached to volunteers' joints to monitor resistance changes in real time. In addition, our PRT fibrous mat also has excellent sensitive performances towards organic gases and humidity, showing its multifunctional ability for detecting various environment stimuli.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultrasensitive mechanical crack-based sensor inspired by the spider sensory system
Kang, D., Pikhitsa, P. V., Choi, Y. W., Lee, C., Shin, S. S., Piao, L., Park, B., Suh, K.-Y., Kim, T.-I., & Choi, M. (2014) · Nature · doi:10.1038/nature14002 · Cited by 1,626
Carbonized Silk Fabric for Ultrastretchable, Highly Sensitive, and Wearable Strain Sensors
Wang, C., Li, X., Gao, E., Jian, M., Xia, K., Wang, Q., Xu, Z., Ren, T., & Zhang, Y. (2016) · Advanced Materials · doi:10.1002/adma.201601572 · Cited by 916
Extremely Elastic Wearable Carbon Nanotube Fiber Strain Sensor for Monitoring of Human Motion
Ryu, S., Lee, P., Chou, J. B., Xu, R., Zhao, R., Hart, A. J., & Kim, S.-G. (2015) · ACS Nano · doi:10.1021/acsnano.5b00599 · Cited by 770
Highly sensitive and flexible strain sensors based on vertical zinc oxide nanowire arrays
Zhang, W., Zhu, R., Nguyen, V., & Yang, R. (2014) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2013.11.004 · Cited by 111
Metadata
- Authors
- Jia, Y., Yue, X., Wang, Y., Yan, C., Zheng, G., Dai, K., Liu, C., & Shen, C.
- Venue
- Composites Part B: Engineering
- Publisher
- Elsevier BV
- Published
- 2020-02
- Volume
- 183
- Pages
- 107696
- ISSN
- 1359-8368 (ISSN-L)
- OpenAlex
- W2995496127
- Cited by
- 180
- References
- 4
- FWCI
- 5.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multifunctional stretchable strain sensor based on polydopamine/ reduced graphene oxide/ electrospun thermoplastic polyurethane fibrous mats for human motion detection and environment monitoring. https://app.cochat.ai/papers/10.1016/j.compositesb.2019.107696
- The paper
- Jia, Y., Yue, X., Wang, Y., Yan, C., Zheng, G., Dai, K., Liu, C., & Shen, C. (2020). Multifunctional stretchable strain sensor based on polydopamine/ reduced graphene oxide/ electrospun thermoplastic polyurethane fibrous mats for human motion detection and environment monitoring. Composites Part B: Engineering. https://doi.org/10.1016/j.compositesb.2019.107696
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.