The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Flexible and high-performance piezoresistive strain sensors based on carbon nanoparticles@polyurethane sponges
Open accessAbstract
Abstract In this work, flexible and high-performance piezoresistive strain sensors were fabricated by simple layer-by-layer electrostatic self-assembly of carbon nanoparticles on commercial polyurethane (PU) sponges. It was shown that the sponge-based strain sensors exhibited obviously positive and negative piezoresistive characteristics under tensile and compressive strains, respectively. The alternate assembly of carbon nanotubes (CNTs) and graphene nanoplatelets (GNPs) contributed to the construction of a more complete conductive network and significantly improved the sensing performance of the sensor due to the synergistic effect between CNTs and GNPs. Compared with the CNT@PU and CNT/GNP@PU sponge strain sensors, the CNT/GNP/CNT@PU sensor had a larger strain detection range and higher linearity. Besides, the CNT/GNP/CNT@PU sponge strain sensor showed high sensitivity (GF = 43,000 at 60% tensile strain and GF = −1.1 at 50% compressive strain), responsive capability to very small strain (0.05%) and outstanding stability during 3000 loading cycles. Due to its excellent sensing performance, the CNT/GNP/CNT@PU sensor enabled monitoring of various physiological activities, including finger movements, wrist bending and walking etc. In addition, a 5 × 5 sensor array based on the sponge-based strain sensor was prepared to achieve accurate identification of weight distribution. This study provides valuable information for the development of flexible strain sensors with high-performance and low-cost.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sensitive, High-Strain, High-Rate Bodily Motion Sensors Based on Graphene–Rubber Composites
Boland, C. S., Khan, U., Backes, C., O’Neill, A., McCauley, J., Duane, S., Shanker, R., Liu, Y., Jurewicz, I., Dalton, A. B., et al. (2014) · ACS Nano · doi:10.1021/nn503454h · Cited by 793
Extremely Elastic Wearable Carbon Nanotube Fiber Strain Sensor for Monitoring of Human Motion
Ryu, S., Lee, P., Chou, J. B., Xu, R., Zhao, R., Hart, A. J., & Kim, S.-G. (2015) · ACS Nano · doi:10.1021/acsnano.5b00599 · Cited by 770
Cited by
Wang, H., Zhou, R., Li, D., Zhang, L., Ren, G., Wang, L., Liu, J., Wang, D., Tang, Z., Lu, G., et al. (2021) · ACS Nano · doi:10.1021/acsnano.1c00259 · Cited by 364
Sharma, A., Ansari, M. Z., & Cho, C. (2022) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2022.113934 · Cited by 95
Metadata
- Authors
- Zhang, X., Xiang, D., Zhu, W., Zheng, Y., Harkin-Jones, E., Wang, P., Zhao, C., Li, H., Wang, B., & Li, Y.
- Venue
- Composites Science and Technology
- Publisher
- Elsevier BV
- Published
- 2020-11
- Volume
- 200
- Pages
- 108437
- ISSN
- 0266-3538 (ISSN-L)
- OpenAlex
- W3082053180
- Cited by
- 191
- References
- 2
- FWCI
- 6.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.