Assignment of the lowest-lying THz absorption signatures in biotin and lactose monohydrate by solid-state density functional theory
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The peaks at 0.53 THz, 1.17 THz, and 1.37 THz are characteristic absorption peaks of α-lactose monohydrate.
“The peaks at 0.53 THz [47, 48], 1.17 THz [49, 50] and 1.37 THz [51, 52] are the characteristic absorption peaks of α-lactose monohydrate [10, 49, 53].”
From THz-TDS Time-Trace Analysis for the Extraction of Material and Metamaterial Parameters (2019) · cites this paper as [48]
Cited by
Sorted by citations
Terahertz spectroscopy and imaging - Modern techniques and applications
Jepsen, P. U., Cooke, D. G., & Koch, M. (2011) · Laser & Photonics Reviews · doi:10.1002/lpor.201000011 · Cited by 2,091 · see citing works
Tutorial: An introduction to terahertz time domain spectroscopy (THz-TDS)
Neu, J., & Schmuttenmaer, C. A. (2018) · Journal of Applied Physics · doi:10.1063/1.5047659 · Cited by 675 · see citing works
Terahertz time-domain spectroscopy
Koch, M., Mittleman, D. M., Ornik, J., & Castro-Camus, E. (2023) · Nature Reviews Methods Primers · doi:10.1038/s43586-023-00232-z · Cited by 410 · see citing works
THz-TDS Time-Trace Analysis for the Extraction of Material and Metamaterial Parameters
Peretti, R., Mitryukovskiy, S., Froberger, K., Mebarki, M. A., Eliet, S., Vanwolleghem, M., & Lampin, J.-F. (2019) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2018.2889227 · Cited by 78 · see citing works
Banks, P. A., Burgess, L., & Ruggiero, M. T. (2021) · Physical Chemistry Chemical Physics · doi:10.1039/d1cp02496e · Cited by 41 · see citing works
On the influence of water on THz vibrational spectral features of molecular crystals
Mitryukovskiy, S., Vanpoucke, D. E. P., Bai, Y., Hannotte, T., Lavancier, M., Hourlier, D., Roos, G., & Peretti, R. (2022) · Physical Chemistry Chemical Physics · doi:10.1039/d1cp03261e · Cited by 28 · see citing works
Osman, O. B., & Arbab, M. H. (2019) · PLOS ONE · doi:10.1371/journal.pone.0216952 · Cited by 27 · see citing works
Peretti, R., Braud, F., Peytavit, E., Dubois, E., & Lampin, J.-F. (2018) · Photonics · doi:10.3390/photonics5020011 · Cited by 27 · see citing works
Terahertz absorption spectra of commonly used antimalarial drugs
Bawuah, P., Zeitler, J. A., Ketolainen, J., & Peiponen, K.-E. (2018) · Optical Review · doi:10.1007/s10043-018-0423-6 · Cited by 9 · see citing works
- Authors
- Allis, D. G., Fedor, A. M., Korter, T. M., Bjarnason, J. E., & Brown, E. R.
- Affiliations
- Syracuse University (US)
- University of California, Santa Barbara (US)
- Corresponding author
- Korter, T.M.
- Venue
- Chemical Physics Letters
- Publisher
- Elsevier BV
- Published
- 2007-06
- Volume
- 440
- Issue
- 4-6
- Pages
- 203-209
- ISSN
- 0009-2614 (ISSN-L)
- OpenAlex
- W2109176501
- Cited by
- 107
- References
- 0
- Citations by year
- 2026: 3 · 2025: 1 · 2023: 3 · 2022: 7 · 2021: 6 · 2020: 5 · 2019: 8 · 2018: 10 · 2017: 5 · 2016: 4 · 2015: 2 · 2014: 5 · 2013: 10 · 2012: 5
- FWCI
- 7.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Chemical Physics Letters (publishedVersion)
- Journal of Bioresource Management (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
- Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Crystallography and molecular interactions
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Spectroscopy and Quantum Chemical Studies
- Keywords
- terahertz absorption, biotin, lactose monohydrate, molecular crystals, hydrogen bond network, intermolecular interactions, low-frequency vibrational modes, crystal structure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review