CoChat

Advances in atomic fountains

Open access
Bize, S., Laurent, P., Abgrall, M., Marion, H., Maksimovic, I., Cacciapuoti, L., Grünert, J., Vian, C., Pereira dos Santos, F., Rosenbusch, P., Lemonde, P., Santarelli, G., Wolf, P., Clairon, A., Luiten, A., Tobar, M., Salomon, C. · 2004 · Comptes Rendus. Physique
Cited by 82

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

This article describes the work performed at BNM-SYRTE (Observatoire de Paris) in the past few years, toward the improvement and the use of microwave frequency standards using laser-cooled atoms. First, recent improvements of the 133 Cs and 87 Rb atomic fountains are described. An important advance is the achievement of a fractional frequency instability of 1.6 × 10 −14 τ − 1 / 2 where τ is the measurement time in seconds, thanks to the routine use of a cryogenic sapphire oscillator as an ultra-stable local frequency reference. The second advance is a powerful method to control the frequency shift due to cold collisions. These two advances lead to a fractional frequency in stability of 2 × 10 −16 at 50 000 s between two independent primary standards. In addition, these clocks realize the SI second with an accuracy of 7 × 10 −16 , one order of magnitude below that of uncooled devices. Tests of fundamental physical laws constitute an important field of application for highly accurate atomic clocks. In a second part, we describe tests of possible variations of fundamental constants using 87 Rb and 133 Cs fountains. The third part is an update on the cold atom space clock PHARAO developed in collaboration with CNES. This clock is one of the main instruments of the ACES/ESA mission which will fly on board the International Space Station in 2007-2008, enabling a new generation of relativity tests.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.crhy.2004.09.003

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 82

Metadata

Authors
Bize, S., Laurent, P., Abgrall, M., Marion, H., Maksimovic, I., Cacciapuoti, L., Grünert, J., Vian, C., Pereira dos Santos, F., Rosenbusch, P., Lemonde, P., Santarelli, G., Wolf, P., Clairon, A., Luiten, A., Tobar, M., & Salomon, C.
Venue
Comptes Rendus. Physique
Published
2004-10-01
Volume
5
Issue
8
Pages
829-843
ISSN
  • 1631-0705 (ISSN-L)
  • 1878-1535
OpenAlex
W2009208781
Cited by
82
References
9
FWCI
7.78
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Advances in atomic fountains. https://app.cochat.ai/papers/10.1016/j.crhy.2004.09.003
The paper
Bize, S., Laurent, P., Abgrall, M., Marion, H., Maksimovic, I., Cacciapuoti, L., Grünert, J., Vian, C., Pereira dos Santos, F., Rosenbusch, P., Lemonde, P., Santarelli, G., Wolf, P., Clairon, A., Luiten, A., Tobar, M., & Salomon, C. (2004). Advances in atomic fountains. Comptes Rendus. Physique. https://doi.org/10.1016/j.crhy.2004.09.003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.