Cited by 47

The DOI matches its Crossref record.

Emissivity of silver and stainless steel from 80K to 300K: Application to ITER thermal shields

Woods, S.I., Jung, T.M., Sears, D.R., Yu, J.·2014·Cryogenics

Overview

Integrity signals

Registry

Crossref · 10.1016/j.cryogenics.2014.01.002

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The Woods et al. system enabled precise emissivity measurements of polished 304 stainless steel across the 80-300 K temperature range.

    “Based on the radiometric method, this system enabled precise emissivity measurements of polished 304 stainless steel across the 80-300 K temperature range [38].”

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 13

  1. Lipa M, Martinez A, Lacroix B, Chatain D. Experience with silver coated vacuum vessel thermal shield at 80K in Tore Supra. In: 2009 23RD IEEE/NPSS symposium on fusion engineering; 2009. p. 603–6. · DOI
  2. Ageladarakis PA, Obert W. On the emissivity of silver coated panels, effect of long term stability and effect of coating thickness. In: DewHughes D, Scurlock RG, Watson JHP, editors. International cryogenic engineering conference 1998; 1998. p. 715–8.
  3. Noh, 2010, Manufacture and test of mock-up for ITER thermal shield, Fusion Eng Des, 85, 1880, 10.1016/j.fusengdes.2010.06.013 · DOI
  4. Herve, 2008, Direct measurement of total emissivities at cryogenic temperatures: application to satellite coatings, Cryogenics, 48, 463, 10.1016/j.cryogenics.2008.07.007 · DOI · Paper page
  5. Tolson W, Or C, Glazer S, Kobel M, Packard E. Determination of coating emittance at cryogenic temperatures for the James Webb Space Telescope – experimental methods and results. In: JB Heaney, LG Burriesci, editors. Cryogenic optical systems and instruments XI. Proceedings of SPIE, vol. 5904; 2005. p. 59040G. · DOI
  6. Duckworth RC, Demko JA, Gouge MJ, Urbahn JA. Measurement of the emissivity of clean and contaminated silver plated copper surfaces at cryogenic temperatures. In: Balachandran U, editor. Advances in cryogenic engineering, vol. 52; 2006. p. 61–68. · DOI · Paper page
  7. Dickson, 1966, Infrared reflectances of metals at cryogenic temperatures—a compilation from the literature, NBS Tech Note, 348, 1
  8. Woods, 2012, Broadband emissivity calibration of highly reflective samples at cryogenic temperatures, Metrologia, 49, 737, 10.1088/0026-1394/49/6/737 · DOI · Paper page
  9. Sievers, 1978, Thermal radiation from metal surfaces, J Opt Soc Am, 68, 1505, 10.1364/JOSA.68.001505 · DOI
  10. Smalley, 1978, The total hemispherical emissivity of copper, J Opt Soc Am, 68, 1516, 10.1364/JOSA.68.001516 · DOI
  11. Ramanathan, 1977, High-temperature emissivities of copper, aluminum and silver, J Opt Soc Am, 67, 32, 10.1364/JOSA.67.000032 · DOI
  12. Beattie, 1960, Spectral emission of radiation by glass, Br J Appl Phys, 11, 151, 10.1088/0508-3443/11/4/303 · DOI
  13. Isard, 1979, Surface reflectivity of strongly absorbing media and calculation of the infrared emissivity of glasses, Infrared Phys, 20, 249, 10.1016/0020-0891(80)90035-4 · DOI

Cited by

Sorted by citations

Metadata

Authors
Woods, S. I., Jung, T. M., Sears, D. R., & Yu, J.
Venue
Cryogenics
Publisher
Elsevier BV
Published
2014-03
Volume
60
Pages
44-48
ISSN
0011-2275
Cited by
47
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review