Cited by 4Refrigeration and Air Conditioning TechnologiesAdsorption and Cooling SystemsHeat Transfer and Boiling Studies

Transient refrigerant distribution in a microchannel heat exchanger heat pump system under different reverse cycle defrosting strategies

Open access
Xiong, Tong, Hu, Longxiang, Liu, Guoqiang, Yan, Gang·2024·Case Studies in Thermal Engineering

Abstract

The migration and redistribution of refrigerant are critical factors that affect the refrigeration system performance. To improve the defrosting and start-up heating performance, it is essential to investigate the transient distribution characteristics of refrigerant mass. However, quantitative studies on the transient distribution of refrigerant during defrosting and start-up heating stages in heat pump systems are scarce. The dynamic characteristics of defrosting and start-up heating cannot be deeply understood from the perspective of refrigerant migration. Therefore, the purpose of this paper is to experimentally study the transient distribution characteristics of refrigerants during defrosting and start-up heating stages for different defrosting strategies. Based on the refrigerant-side dynamic characteristics, the defrosting cycle is divided into three stages for the defrosting strategy with the indoor fan off, the indoor coil charging stage, accumulator charging stage, and wet compression stage. Additionally, for the defrosting strategy with the indoor fan on, it is divided into two stages: the indoor coil charging stage and the outdoor coil discharging stage. For the defrosting strategy with the indoor fan off, the wet compression phenomenon occurs at 240 s, which poses significant challenges to the stability of the compressor. At the end of defrosting, the accumulator retains the most refrigerant for both defrosting strategies. From the perspective of refrigerant transient distribution, the start-up heating stage is the process of refrigerant migration from the accumulator to indoor and outdoor coils. The two main factors that affect start-up heating performance are heating the indoor coil metal, and vaporizing the liquid refrigerant in the accumulator. For the defrosting strategy with indoor fan on, the energy consumption of heating the indoor coil and vaporizing the liquid refrigerant is reduced by 45.7 % and 48.9 % during start-up heating. Based on the transient refrigerant distribution experiment, some methods to improve defrosting and start-up heating are also proposed. This study can provide useful insights into the transient distribution of refrigerants and provide guidance for defrosting optimization.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.csite.2024.105069

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 39 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Xiong, T., Hu, L., Liu, G., & Yan, G.
Affiliations
Xi'an Jiaotong University (CN)
Corresponding author
Liu, Guoqiang
Venue
Case Studies in Thermal Engineering
Publisher
Elsevier BV
Published
2024-09
Volume
61
Pages
105069
ISSN
2214-157X (ISSN-L)
OpenAlex
W4402127566
Cited by
4
References
39
Citations by year
2026: 1 · 2025: 3
FWCI
0.54
Type
journal article
Language
en
Open access
Locations
  • Case Studies in Thermal Engineering (publishedVersion, cc-by-nc-nd)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
National Natural Science Foundation of China (52306021)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Boiling Studies
Keywords
microchannel heat exchangers, heat pumps, refrigerant distribution, wet compression

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review