Tympanic, Infrared Skin, and Temporal Artery Scan Thermometers Compared with Rectal Measurement in Children: A Real-Life Assessment
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: Body temperature measurement in children is of clinical relevance. Although rectal measurement is the gold standard, less invasive tools have become available. We aimed to describe the accuracy of tympanic, infrared skin, or temporal artery scan thermometers compared with rectal measurement to reflect core temperature. METHODS: Rectal (Filac 3000; Covidien, Mechelen, Belgium), tympanic (AccuSystem Genius2 Typmanic Infrared Ear Thermometer, Covidien, Mechelen, Belgium), temporal artery scan (Exergen, Exergen Corp, Watertown, Massachusetts), and infrared (ThermoFlash Contactless Medical Electronic Thermometer, Visiomedlab, Paris, France) body temperature measurements were randomly performed and readings were collected once. Temperature readings were described as median and range, and observations were compared with rectal temperature readings (using Wilcoxon, Bland-Altman, sensitivity, and specificity tests). The child's comfort was assessed by the child, parent, and nurse (using Likert scales) and ease of use was assessed by nurses (using visual analog scale). RESULTS: Based on observations in 294 (median age = 3.2 years, range = 0.02-17 years) children, the mean difference was 0.49°C (tympanic scan; P < 0.0001), 0.34°C (infrared skin scan; P < 0.0001), and 0°C (temporal artery scan; P = 0.9288), respectively, when compared with rectal temperature readings. Based on visual inspection of Bland-Altman plots, all tools overestimated the temperature at lower body temperature and underestimated the temperature at higher body temperature, resulting in a sensitivity of 22% to 41% and a specificity of 98% to 100% for rectal temperatures above 38°C. The Likert scale scores and the visual analog scale scores for rectal measurement were only slightly higher when compared with the other methods. CONCLUSIONS: All noninvasive techniques underperformed compared with rectal measurement. The temporal artery scan deviations were smallest, but all noninvasive techniques overestimate lower temperatures and underestimate higher temperatures compared with rectal measurement. In our hands, temporal artery scan measurement seems to be second best, but not yet ideal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dodd, S. R., Lancaster, G. A., Craig, J. V., Smyth, R. L., & Williamson, P. R. (2006) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.10.004 · Cited by 90 · cited 2×
“The underperformance of tympanic or infrared skin scan thermometers also confirms previous studies.(6,8,13) In a recent metaanalysis by Dodd et al,(8) the pooled estimates of sensitivity and specificity for tympanic scan thermometry were 63.”
BackgroundResult
Research works printed but not linked: 18
- Davis, 2013, NICE guideline: feverish illness in children—assessment and initial management in children younger than 5 years, Arch Dis Child Educ Pract Ed, 98, 232, 10.1136/archdischild-2013-304792 · DOI
- Walson, 2006, Antipyretic efficacy and tolerability of a single intravenous dose of the acetaminophen prodrug propacetamol in children: a randomized, double-blind, placebo-controlled trial, Clin Ther, 28, 762, 10.1016/j.clinthera.2006.05.005 · DOI
- Allegaert, 2011, Pharmacokinetics and pharmacodynamics of intravenous acetaminophen in neonates, Expert Rev Clin Pharmacol, 4, 713, 10.1586/ecp.11.50 · DOI
- Craig, 2002, Infrared ear thermometry compared with rectal thermometry in children: a systematic review, Lancet, 360, 603, 10.1016/S0140-6736(02)09783-0 · DOI · Paper page
- Craig, 2000, Temperature measured at the axilla compared with rectum in children and young people: a systematic review, BMJ, 320, 1174, 10.1136/bmj.320.7243.1174 · DOI · Paper page
- Paes, 2010, Accuracy of tympanic and infrared skin thermometers in children, Arch Dis Child, 95, 974, 10.1136/adc.2010.185801 · DOI · Paper page
- Batra, 2013, Comparison of rectal, axillary, tympanic and temporal artery thermometer in the pediatric emergency room, Pediatr Emerg Care, 29, 63, 10.1097/PEC.0b013e31827b5427 · DOI · Paper page
- Eyelade, 2011, Esophageal, tympanic, rectal and skin temperatures in children undergoing surgery with general anesthesia, J Perianesth Nurs, 26, 151, 10.1016/j.jopan.2011.03.009 · DOI
- Devrim, 2007, Measurement accuracy of fever by tympanic and axillary thermometry, Pediatr Emerg Care, 23, 16, 10.1097/PEC.0b013e31802c61e6 · DOI
- Dew, 2006, Is tympanic membrane thermometry the best method for recording temperature in children?, J Child Health Care, 10, 96, 10.1177/1367493506062550 · DOI
- Myny, 2005, Temporal scanner thermometry: a new method of core temperature estimation in ICU patients, Scott Med J, 50, 15, 10.1177/003693300505000106 · DOI · Paper page
- Selent, 2013, Mass screening for fever in children: a comparison of 3 infrared thermal detection systems, Pediatr Emerg Care, 29, 305, 10.1097/PEC.0b013e3182854465 · DOI · Paper page
- Fortuna, 2010, Accuracy of non-contact infrared thermometry versus rectal thermometry in young children evaluated in the emergency department for fever, J Emerg Nurs, 36, 101, 10.1016/j.jen.2009.07.017 · DOI
- Chiappini, 2011, Performance of non-contact infrared thermometer for detecting febrile children in hospital and ambulatory settings, J Clin Nurs, 20, 1311, 10.1111/j.1365-2702.2010.03565.x · DOI · Paper page
- Reynolds, 2012, Are temporal artery temperatures accurate enough to replace rectal temperature measurement in pediatric ED patients?, J Emerg Nurs.
- Bahorski, 2012, Temperature measurement in pediatrics: a comparison of the rectal method versus the temporal artery method, J Pediatr Nurs, 27, 243, 10.1016/j.pedn.2010.12.015 · DOI
- Hopchet, 2011, Does intravenous paracetamol administration affect body temperature in neonates?, Arch Dis Child, 96, 301, 10.1136/adc.2010.203778 · DOI
- Van den Anker, 2013, Optimising the management of fever and pain in children, Int J Clin Pract Suppl, 26, 10.1111/ijcp.12056 · DOI
Cited by
Thermoregulatory disorders and illness related to heat and cold stress
Cheshire, W. P. (2016) · Autonomic Neuroscience · doi:10.1016/j.autneu.2016.01.001 · Cited by 349
Niven, D. J., Gaudet, J. E., Laupland, K. B., Mrklas, K. J., Roberts, D. J., & Stelfox, H. T. (2015) · Annals of Internal Medicine · doi:10.7326/m15-1150 · Cited by 240
2016 Update of the Italian Pediatric Society Guidelines for Management of Fever in Children
Chiappini, E., Venturini, E., Remaschi, G., Principi, N., Longhi, R., Tovo, P.-A., Becherucci, P., Bonsignori, F., Esposito, S., Festini, F., et al. (2017) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2016.09.043 · Cited by 104
Temperature measurements with a temporal scanner: systematic review and meta-analysis
Geijer, H., Udumyan, R., Lohse, G., & Nilsagård, Y. (2016) · BMJ Open · doi:10.1136/bmjopen-2015-009509 · Cited by 66
“0°C threshold in the same population, 734 participants.(18) 21 28 40 The results were similar with SE 0.”
ResultPecoraro, V., Petri, D., Costantino, G., Squizzato, A., Moja, L., Virgili, G., & Lucenteforte, E. (2021) · Internal and Emergency Medicine · doi:10.1007/s11739-020-02556-0 · Cited by 49
“Allegaert 2014 [23] RCT ED Children 294 Rectal, digital Tympanic, infrared Forehead, infrared Temporal artery, infrared”
Metadata
- Authors
- Allegaert, K., Casteels, K., van Gorp, I., & Bogaert, G.
- Venue
- Current Therapeutic Research
- Publisher
- Elsevier BV
- Published
- 2014-12
- Volume
- 76
- Pages
- 34-38
- ISSN
- 0011-393X (ISSN-L)
- OpenAlex
- W2121957794
- Cited by
- 61
- References
- 1
- FWCI
- 4.57
- Type
- journal article
- Language
- en
- Open access
- gold
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- creativecommons.org/licenses/by-nc-sa/3.0/ (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.