In vitro and in vivo studies of anti-bacterial copper-bearing titanium alloy for dental application
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
OBJECTIVE A novel copper-bearing titanium alloy (Ti-Cu) was fabricated for dental application that is expected to efficiently restrain the growth of bacteria and discourage biofilm formation. The aim of this study was to investigate both the antibacterial activity and biofilm inhibition of Ti-Cu alloy in vitro, and the antibacterial effect of Ti-Cu implant in early stage of peri-implantitis in vivo. METHODS Staphylococcus aureus and Escherichia coli were selected to evaluate the antibacterial activity of Ti-Cu alloy and Ti served as control. The antibacterial rate, attached bacteria and developed biofilms were studied from quantitative antibacterial test, biofilm observation and bacterial morphological examination. Electrochemical tests were used to investigate the corrosion property of Ti-Cu alloy. Furthermore, both Ti and Ti-Cu dental implants were manufactured and then implanted in the mandibular premolar sites of beagle dogs for 3 months with ligature-infected treatment. Implant-tissue samples were prepared for radiographic analysis, Micro-CT evaluation and histological examination. RESULTS Ti-Cu alloy was found to efficiently kill the attached bacteria by ways of damaging cell membranes and cell walls and strongly inhibit the biofilm formation. However, Ti-Cu alloy had excellent corrosion resistance similar with Ti. Further, Ti-Cu dental implants showed superior capacities of inhibiting the bone resorption caused by bacterial infection and enhancing bone formation. SIGNIFICANCE Ti-Cu alloy strongly inhibited biofilm formation in vitro and prevented bacterial infection associated with dental implant in vivo, making it great potential for application in dental implants with excellent antibacterial viability and positive effect against bone resorption induced by peri-implantitis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanisms of biofilm resistance to antimicrobial agents
Mah, T.-F. C., & O'Toole, G. A. (2001) · Trends in Microbiology · doi:10.1016/s0966-842x(00)01913-2 · Cited by 3,921
Survival strategies of infectious biofilms
Fux, C. A., Costerton, J. W., Stewart, P. S., & Stoodley, P. (2005) · Trends in Microbiology · doi:10.1016/j.tim.2004.11.010 · Cited by 1,812
Wu, C., Zhou, Y., Xu, M., Han, P., Chen, L., Chang, J., & Xiao, Y. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2012.09.066 · Cited by 864
Experimental breakdown of peri‐implant and periodontal tissues. A study in the beagle dog
Lindhe, J., Berglundh, T., Ericsson, I., Liljenberg, B., & Marinello, C. (1992) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1992.030102.x · Cited by 667
Antibacterial activity of chitosan tripolyphosphate nanoparticles loaded with various metal ions
Du, W.-L., Niu, S.-S., Xu, Y.-L., Xu, Z.-R., & Fan, C.-L. (2009) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2008.07.039 · Cited by 575
Biological actions of silver nanoparticles embedded in titanium controlled by micro-galvanic effects
Cao, H., Liu, X., Meng, F., & Chu, P. K. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.09.066 · Cited by 344
Li, J., Zhai, D., Lv, F., Yu, Q., Ma, H., Yin, J., Yi, Z., Liu, M., Chang, J., & Wu, C. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.03.011 · Cited by 340
Li, Y., Liu, L., Wan, P., Zhai, Z., Mao, Z., Ouyang, Z., Yu, D., Sun, Q., Tan, L., Ren, L., et al. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.08.031 · Cited by 286
Self-citationZhang, E., Wang, X., Chen, M., & Hou, B. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2016.08.033 · Cited by 285
Immobilized antibiotics to prevent orthopaedic implant infections
Hickok, N. J., & Shapiro, I. M. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.03.015 · Cited by 283
Cited by
Antibacterial metals and alloys for potential biomedical implants
Zhang, E., Zhao, X., Hu, J., Wang, R., Fu, S., & Qin, G. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.01.030 · Cited by 552
Antimicrobial Copper-Based Materials and Coatings: Potential Multifaceted Biomedical Applications
Mitra, D., Kang, E.-T., & Neoh, K. G. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b17815 · Cited by 322
Shen, X., Zhang, Y., Ma, P., Sutrisno, L., Luo, Z., Hu, Y., Yu, Y., Tao, B., Li, C., & Cai, K. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.05.008 · Cited by 291
Role of Cu element in biomedical metal alloy design
Zhang, E., Fu, S., Wang, R., Li, H., Liu, Y., Ma, Z., Liu, G., Zhu, C., Qin, G., & Chen, D. (2019) · Rare Metals · doi:10.1007/s12598-019-01245-y · Cited by 172
Self-citationQu, X., Yang, H., Jia, B., Yu, Z., Zheng, Y., & Dai, K. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.09.041 · Cited by 168
Metadata
- Authors
- Liu, R., Tang, Y., Zeng, L., Zhao, Y., Ma, Z., Sun, Z., Xiang, L., Ren, L., & Yang, K.
- Venue
- Dental Materials
- Publisher
- Elsevier BV
- Published
- 2018-08
- Volume
- 34
- Issue
- 8
- Pages
- 1112-1126
- ISSN
- 0109-5641 (ISSN-L)
- OpenAlex
- W2800488516
- Cited by
- 198
- References
- 31
- FWCI
- 7.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.