Clinical performance and chemical-physical properties of bulk fill composites resin —a systematic review and meta-analysis
The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
OBJECTIVES The objective of this study was to perform a meta-analysis of clinical and laboratory studies to compare the performance of bulk-fill and conventional composite resins in terms of polymerization shrinkage, polymerization stress, cusp deflection, marginal quality, degree of conversion, microhardness, flexural strength, fracture strength and clinical performance. DATA One hundred three articles were included in this study, and the Peto method was used to compare the bulk-fill and conventional composites using the RevMan software. SOURCES Searches were performed in the PubMed and Scopus databases. STUDY SELECTION Laboratory studies and randomized clinical trials comparing one of the previous detailed outcomes between bulk-fill and control composites were included. CONCLUSIONS The bulk-fill composite resins showed less shrinkage, polymerization stress, cusp deflection and microhardness than conventional composites, while both materials presented a similar marginal quality, flexural strength and fracture strength. Also, bulk-fill materials with regular viscosity showed similar shrinkage. The conversion of bulk-fill materials with flowable consistency were similar to conventional composite resins with a thickness of up to 2mm and greater than conventional composites with a thickness greater than 2mm. Despite these in vitro differences, the clinical performance of bulk-fill and conventional composite resins was similar in randomized clinical trials, with one to ten years of follow up. In conclusion, the bulk-fill materials show better or similar performance to the conventional materials in clinical trials and laboratory studies in terms of volumetric shrinkage, polymerization stress, cusps deflection and marginal quality, with the only exception being the lower level of microhardness observed for bulk-fill composites with thickness up to 2mm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Resin composite—State of the art
Ferracane, J. L. (2011) · Dental Materials · doi:10.1016/j.dental.2010.10.020 · Cited by 2,188
Polymerization Shrinkage Stress Kinetics and Related Properties of Bulk-fill Resin Composites
El-Damanhoury, H. M., & Platt, J. A. (2013) · Operative Dentistry · doi:10.2341/13-017-l · Cited by 400
Bulk-Fill Resin Composites: Polymerization Contraction, Depth of Cure, and Gap Formation
Benetti, A. R., Havndrup-Pedersen, C., Honoré, D., Pedersen, M., & Pallesen, U. (2014) · Operative Dentistry · doi:10.2341/13-324-l · Cited by 384
Bulk-fill resin composites: Polymerization properties and extended light curing
Zorzin, J. I., Maier, E., Harre, S., Fey, T., Belli, R., Lohbauer, U., Petschelt, A., & Taschner, M. (2015) · Dental Materials · doi:10.1016/j.dental.2014.12.010 · Cited by 367
Sarkis-Onofre, R., Skupien, J., Cenci, M., Moraes, R., & Pereira-Cenci, T. (2014) · Operative Dentistry · doi:10.2341/13-070-lit · Cited by 362
Kim, R. J.-Y., Kim, Y.-J., Choi, N.-S., & Lee, I.-B. (2015) · Journal of Dentistry · doi:10.1016/j.jdent.2015.02.002 · Cited by 288
Degree of conversion of bulk-fill compared to conventional resin-composites at two time intervals
Alshali, R. Z., Silikas, N., & Satterthwaite, J. D. (2013) · Dental Materials · doi:10.1016/j.dental.2013.05.011 · Cited by 283
Polymerization shrinkage kinetics and shrinkage-stress in dental resin-composites
Alsunbul, H., Silikas, N., & Watts, D. C. (2016) · Dental Materials · doi:10.1016/j.dental.2016.05.006 · Cited by 246
Gonçalves, F., Kawano, Y., Pfeifer, C., Stansbury, J. W., & Braga, R. R. (2009) · European Journal of Oral Sciences · doi:10.1111/j.1600-0722.2009.00636.x · Cited by 215
Self-citationContraction stress related to composite inorganic content
Gonçalves, F., Kawano, Y., & Braga, R. R. (2010) · Dental Materials · doi:10.1016/j.dental.2010.03.015 · Cited by 178
Self-citationPolymerization shrinkage assessment of dental resin composites: a literature review
Kaisarly, D., & Gezawi, M. E. (2016) · Odontology · doi:10.1007/s10266-016-0264-3 · Cited by 165
Pfeifer, C. S., Shelton, Z. R., Braga, R. R., Windmöller, D., Machado, J. C., & Stansbury, J. W. (2010) · European Polymer Journal · doi:10.1016/j.eurpolymj.2010.11.007 · Cited by 144
Self-citationAtalay, C., Yazici, A., Horuztepe, A. S., Nagaş, E., Ertan, A. A., & Özgünaltay, G. (2016) · Operative Dentistry · doi:10.2341/15-320-l · Cited by 133
Contraction Stress Determinants in Dimethacrylate Composites
Gonçalves, F., Pfeifer, C. S., Ferracane, J. L., & Braga, R. R. (2008) · Journal of Dental Research · doi:10.1177/154405910808700404 · Cited by 127
Self-citationEffect of resin thickness on the microhardness and optical properties of bulk-fill resin composites
Kim, E.-H., Jung, K.-H., Son, S., Hur, B., Kwon, Y. H., & Park, J. (2015) · Restorative Dentistry & Endodontics · doi:10.5395/rde.2015.40.2.128 · Cited by 123
Tauböck, T. T., Jäger, F., & Attin, T. (2018) · Odontology · doi:10.1007/s10266-018-0369-y · Cited by 123
One‐year clinical evaluation of different types of bulk‐fill composites
Bayraktar, Y., Ercan, E., Hamidi, M. M., & Çolak, H. (2016) · Journal of Investigative and Clinical Dentistry · doi:10.1111/jicd.12210 · Cited by 112
Thirty-Six-Month Clinical Comparison of Bulk Fill and Nanofill Composite Restorations
Yazici, A., Antonson, S., Kütük, Z. B., & Ergin, E. (2017) · Operative Dentistry · doi:10.2341/16-220-c · Cited by 109
Influence of matrix composition on polymerization stress development of experimental composites
Gonçalves, F., Pfeifer, C. S., Stansbury, J. W., et al. (2010) · Dental Materials · doi:10.1016/j.dental.2010.03.014 · Cited by 105
Self-citationShrinkage assessment of low shrinkage composites using micro-computed tomography
Hirata, R., Clozza, E., Giannini, M., Farrokhmanesh, E., Janal, M. N., Tovar, N., Bonfante, E. A., & Coelho, P. G. (2014) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.33258 · Cited by 97
Management of Shrinkage Stresses in Direct Restorative Light‐Cured Composites: A Review
Mantri, S., & Mantri, S. S. (2013) · Journal of Esthetic and Restorative Dentistry · doi:10.1111/jerd.12047 · Cited by 95
Heck, K., Manhart, J., Hickel, R., & Diegritz, C. (2018) · Dental Materials · doi:10.1016/j.dental.2018.03.023 · Cited by 93
Degree of Conversion and Polymerization Shrinkage of Bulk-Fill Resin-Based Composites
Yu, P., Yap, A. U. J., & Wang, X. (2016) · Operative Dentistry · doi:10.2341/16-027-l · Cited by 93
Tauböck, T. T., Feilzer, A. J., Buchalla, W., Kleverlaan, C. J., Krejci, I., & Attin, T. (2014) · European Journal Of Oral Sciences · doi:10.1111/eos.12139 · Cited by 90
Kemaloğlu, H., Kaval, M. E., Türkün, M., & Kurt, S. M. (2015) · Dental Materials Journal · doi:10.4012/dmj.2014-326 · Cited by 82
Monomer conversion and shrinkage force kinetics of low-viscosity bulk-fill resin composites
Marović, D., Tauböck, T. T., Attin, T., Pandurić, V., & Tarle, Z. (2014) · Acta Odontologica Scandinavica · doi:10.3109/00016357.2014.992810 · Cited by 80
Algamaiah, H., Sampaio, C. S., Rigo, L. C., Janal, M. N., Giannini, M., Bonfante, E. A., Coelho, P. G., Reis, A. F., & Hirata, R. (2016) · Journal of Esthetic and Restorative Dentistry · doi:10.1111/jerd.12275 · Cited by 62
Çolak, H., Tokay, U., Uzgur, R., Hamidi, M. M., & Ercan, E. (2017) · Nigerian Journal of Clinical Practice · doi:10.4103/1119-3077.212449 · Cited by 59
Comparison of flowable bulk-fill and flowable resin-based composites: an in vitro analysis
Engelhardt, F., Hahnel, S., Preis, V., & Rosentritt, M. (2016) · Clinical Oral Investigations · doi:10.1007/s00784-015-1700-4 · Cited by 55
Al‐Harbi, F. A., Kaisarly, D., Michna, A., ArRejaie, A. S., Bader, D., & Gezawi, M. E. (2015) · Operative Dentistry · doi:10.2341/14-152-l · Cited by 53
Shibasaki, S., Takamizawa, T., Nojiri, K., Imai, A., Tsujimoto, A., Endo, H., Suzuki, S., Shunichi, S. U. D. A., Barkmeier, W., Latta, M., et al. (2017) · Operative Dentistry · doi:10.2341/16-385-l · Cited by 51
Polymerization stress of resin composites as a function of system compliance
Gonçalves, F., Pfeifer, C. S., Meira, J. B. C., Ballester, R. Y., Lima, R. G., & Braga, R. R. (2007) · Dental Materials · doi:10.1016/j.dental.2007.06.032 · Cited by 51
Self-citationEffect of low-shrinkage monomers on the physicochemical properties of experimental composite resin
He, J., Garoushi, S. K., VALLITTU, P. K., & Lassila, L. V. J. (2018) · Acta Biomaterialia Odontologica Scandinavica · doi:10.1080/23337931.2018.1444488 · Cited by 42
Cuspal Deflection in Premolar Teeth Restored with Bulk-Fill Resin-Based Composite Materials
Elsharkasi, M. M. O., Platt, J. A., Cook, N. B., Yassen, G. H., & Matis, B. A. (2017) · Operative Dentistry · doi:10.2341/16-072-l · Cited by 42
Polymerization stress evolution of a bulk-fill flowable composite under different compliances
Guo, Y., Landis, F. A., Wang, Z., Bai, D., Jiang, L., & Chiang, M. Y. M. (2016) · Dental Materials · doi:10.1016/j.dental.2016.01.009 · Cited by 39
Two-year clinical performance of sonic-resin placement system in posterior restorations.
Atabek, D., Aktaş, N., Sakaryali, D., & Bani, M. (2017) · PubMed · doi:10.3290/j.qi.a38855 · Cited by 37
Almeida, L. J. D. S., Penha, K. J. D. S., Souza, A. F., Lula, E. C. D. O., Magalhães, F. A. C., Lima, D. M., & Firoozmand, L. M. (2017) · Brazilian Oral Research · doi:10.1590/1807-3107bor-2017.vol31.0100 · Cited by 34
Frascino, S. M. B., Fagundes, T. C., Silva, U., Rahal, V., Barboza, A., dos Santos, P., & Briso, A. L. F. (2019) · Operative Dentistry · doi:10.2341/18-230-c · Cited by 31
Haak, R., Näke, T., Park, K.-J., Ziebolz, D., Krause, F., & Schneider, H. (2018) · Odontology · doi:10.1007/s10266-018-0402-1 · Cited by 30
Vinagre, A., Ramos, J. C., Alves, S. J. D. M., Messias, A., Alberto, N., & Nogueira, R. N. (2016) · International Journal of Biomaterials · doi:10.1155/2016/7134283 · Cited by 29
Yarmohammadi, E., Jahromi, P. R., & Akbarzadeh, M. (2018) · The Journal of Contemporary Dental Practice · doi:10.5005/jp-journals-10024-2320 · Cited by 20
Effect of composite type and placement technique on cuspal strain
Ólafsson, V. G., Ritter, A. V., Swift, E. J., Boushell, L. W., Ko, C., Jackson, G. R., Ahmed, S. N., & Donovan, T. E. (2017) · Journal of Esthetic and Restorative Dentistry · doi:10.1111/jerd.12339 · Cited by 20
Polymerization Shrinkage of Bulk Fill Composites and its Correlation with Bond Strength
Almeida, L. J. D. S., Lula, E. C. D. O., Penha, K. J. D. S., Correia, V. S., Magalhães, F. A. C., Lima, D. M., & Firoozmand, L. M. (2018) · Brazilian Dental Journal · doi:10.1590/0103-6440201801838 · Cited by 17
Boaro, L. C. C., Meira, J. B. C., Ballester, R. Y., & Braga, R. R. (2013) · Dental Materials · doi:10.1016/j.dental.2013.07.011 · Cited by 12
Nguyen, K., Wong, R., Palamara, J. E. A., & Burrow, M. (2015) · Operative Dentistry · doi:10.2341/14-331-l · Cited by 11
Evaluation of polymerization shrinkage of dental composites by microcomputed tomography
Kamalak, H., & Kamalak, A. (2018) · Biomedical Research - India · doi:10.4066/biomedicalresearch.29-18-314 · Cited by 10
Tekçe, N., Tuncer, S., Demırcı, M., Özel, E., & Aykor, A. (2018) · Journal of Adhesion Science and Technology · doi:10.1080/01694243.2018.1442283 · Cited by 5
Arora, V., Arora, P., & Soliman, M. (2018) · World Journal of Dentistry · doi:10.5005/jp-journals-10015-1534 · Cited by 4
Cited by
Hussein Kamel, J., & Salman, F. D. (2023) · Acta Scientific Medical Sciences · doi:10.31080/asms.2023.07.1518
Metadata
- Authors
- Cidreira Boaro, L. C., Pereira Lopes, D., de Souza, A. S. C., Lie Nakano, E., Ayala Perez, M. D., Pfeifer, C. S., & Gonçalves, F.
- Venue
- Dental Materials
- Publisher
- Elsevier BV
- Published
- 2019-10
- Volume
- 35
- Issue
- 10
- Pages
- e249-e264
- ISSN
- 0109-5641 (ISSN-L)
- OpenAlex
- W2967486597
- Cited by
- 170
- References
- 48
- FWCI
- 7.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.