Clinical efficacy and patient satisfaction with U-500 insulin use
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Aims The prevalence of highly insulin resistant diabetes is increasing and treatment requires the use of very high doses of insulin. This study was performed to analyze efficacy and patient satisfaction with use of U-500 concentrated insulin. Methods The medical records of 40 patients using U-500 insulin for at least 3 months were reviewed. A quality of life questionnaire was administered 6 or more months after U-500 was initiated. Effects of U-500 use on HbA1c, weight, total daily insulin use, hypoglycemia, and patient satisfaction were measured. Results Patients had uncontrolled diabetes for 3 years prior to U-500 initiation despite insulin titration. Subjects required continued insulin titration to attain glycemic control even after U-500 initiation, but HbA1c decreased by 1.5% within three months. Subjects gained weight with insulin titration. Hypoglycemic symptoms increased early after transition to U-500 insulin, but patients reported fewer hypoglycemic episodes on the quality of life questionnaire. Patient satisfaction with diabetes care and control was significantly improved following transition to U-500 insulin. Conclusions Use of U-500 insulin assists with attaining glycemic control in highly insulin resistant subjects, but at the cost of weight gain and increased insulin doses. However, patient satisfaction is improved with U-500 insulin use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weight Gain Associated With Intensive Therapy in the Diabetes Control and Complications Trial
The DCCT Research Group (1988) · Diabetes Care · doi:10.2337/diacare.11.7.567 · Cited by 345
Galloway, J. A., Spradlin, C. T., Nelson, R. L., Wentworth, S. M., Davidson, J. A., & Swarner, J. L. (1981) · Diabetes Care · doi:10.2337/diacare.4.3.366 · Cited by 226
Cited by
de la Peña, A., Riddle, M., Morrow, L. A., Jiang, H. H., Linnebjerg, H., Scott, A., Win, K. M., Hompesch, M., Mace, K. F., Jacobson, J. G., et al. (2011) · Diabetes Care · doi:10.2337/dc11-0721 · Cited by 125
“A number of case series have been published describing the use of U-500R injected twice daily (4,7) or three times daily (3,5,6) without the use of basal insulin.”
BackgroundClinical use of U-500 regular insulin: Review and meta-analysis
Reutrakul, S., Wroblewski, K., & Brown, R. L. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600229 · Cited by 94
Hood, R. C., Arakaki, R. F., Wysham, C., Li, Y. G., Settles, J. A., & Jackson, J. A. (2015) · Endocrine Practice · doi:10.4158/ep15612.or · Cited by 61
Wysham, C., Hood, R. C., Warren, M. L., Wang, T., Morwick, T. M., & Jackson, J. A. (2016) · Endocrine Practice · doi:10.4158/ep15959.or · Cited by 29
Hood, R. C., Borra, S., Fan, L., Pollom, R. D., Huang, A., & Chen, J. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.05.006 · Cited by 9
Metadata
- Authors
- Dailey, A. M., Williams, S., Taneja, D., & Tannock, L. R.
- Venue
- Diabetes Research and Clinical Practice
- Publisher
- Elsevier BV
- Published
- 2010-06
- Volume
- 88
- Issue
- 3
- Pages
- 259-264
- ISSN
- 0168-8227 (ISSN-L)
- OpenAlex
- W2050013627
- Cited by
- 39
- References
- 2
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical efficacy and patient satisfaction with U-500 insulin use. https://app.cochat.ai/papers/10.1016/j.diabres.2010.02.012
- The paper
- Dailey, A. M., Williams, S., Taneja, D., & Tannock, L. R. (2010). Clinical efficacy and patient satisfaction with U-500 insulin use. Diabetes Research and Clinical Practice. https://doi.org/10.1016/j.diabres.2010.02.012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.