Dermoscopy diagnosis of cancerous lesions utilizing dual deep learning algorithms via visual and audio (sonification) outputs: Laboratory and prospective observational studies

Open access
Walker, B.N., Rehg, J.M., Kalra, A., Winters, R.M., Drews, P., Dascalu, J., David, E.O., Dascalu, A. · 2019 · EBioMedicine
Cited by 55

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Early diagnosis of skin cancer lesions by dermoscopy, the gold standard in dermatological imaging, calls for a diagnostic upscale. The aim of the study was to improve the accuracy of dermoscopic skin cancer diagnosis through use of novel deep learning (DL) algorithms. An additional sonification-derived diagnostic layer was added to the visual classification to increase sensitivity. METHODS: Two parallel studies were conducted: a laboratory retrospective study (LABS, n = 482 biopsies) and a non-interventional prospective observational study (OBS, n = 63 biopsies). A training data set of biopsy-verified reports, normal and cancerous skin lesions (n = 3954), were used to develop a DL classifier exploring visual features (System A). The outputs of the classifier were sonified, i.e. data conversion into sound (System B). Derived sound files were analyzed by a second machine learning classifier, either as raw audio (LABS, OBS) or following conversion into spectrograms (LABS) and by image analysis and human heuristics (OBS). The OBS criteria outcomes were System A specificity and System B sensitivity as raw sounds, spectrogram areas or heuristics. FINDINGS: LABS employed dermoscopies, half benign half malignant, and compared the accuracy of Systems A and B. System A algorithm resulted in a ROC AUC of 0.976 (95% CI, 0.965-0.987). Secondary machine learning analysis of raw sound, FFT and Spectrogram ROC curves resulted in AUC's of 0.931 (95% CI 0.881-0.981), 0.90 (95% CI 0.838-0.963) and 0.988 (CI 95% 0.973-1.001), respectively. OBS analysis of raw sound dermoscopies by the secondary machine learning resulted in a ROC AUC of 0.819 (95% CI, 0.7956 to 0.8406). OBS image analysis of AUC for spectrograms displayed a ROC AUC of 0.808 (CI 95% 0.6945 To 0.9208). By applying a heuristic analysis of Systems A and B a sensitivity of 86% and specificity of 91% were derived in the clinical study. INTERPRETATION: Adding a second stage of processing, which includes a deep learning algorithm of sonification and heuristic inspection with machine learning, significantly improves diagnostic accuracy. A combined two-stage system is expected to assist clinical decisions and de-escalate the current trend of over-diagnosis of skin cancer lesions as pathological. FUND: Bostel Technologies. Trial Registration clinicaltrials.gov Identifier: NCT03362138.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ebiom.2019.01.028

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 55

Metadata

Authors
Walker, B. N., Rehg, J. M., Kalra, A., Winters, R. M., Drews, P., Dascalu, J., David, E. O., & Dascalu, A.
Venue
EBioMedicine
Publisher
Elsevier BV
Published
2019-02
Volume
40
Pages
176-183
ISSN
2352-3964 (ISSN-L)
OpenAlex
W2910035750
Cited by
55
References
5
FWCI
2.81
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.